239
Parameter clear/ All parameter clear
4.23 Parameter clear/ All parameter clear
POINT
Set "1" in
Pr.CL Parameter clear, ALLC all parameter clear
to initialize all parameters. (Parameters are not cleared
when "1" is set in
Pr. 77Parameter write selection
.)
Refer to the extended parameter list on
page 52
for parameters cleared with this operation.
Operation Display
1.
Screen at powering on
The monitor display appears.
2.
Press
to choose the PU operation mode.
PU indication is lit.
3.
Press
to choose the parameter setting
mode.
PRM indication is lit.
(The parameter number read previously appears.)
4.
Turn
until
(
) appears.
Parameter clear
All parameter clear
5.
Press
to read the currently set value.
"
"(initial value) appears.
6.
Turn
to change it to the set value "
".
7.
Press
to set.
Parameter clear
All parameter clear
Flicker ··· Parameter setting complete!!
Turn
to read another parameter.
Press
to show the setting again.
Press
twice to show the next parameter.
Setting
Description
0
Not executed.
1
Return parameters to the initial values. (Parameter clear returns all parameters except
calibration
parameters, terminal function selection parameters
to the initial values.
Refer to the parameter list on
page 52
for availability of parameter clear and all parameter clear.
REMARKS
are displayed alternately ... Why?
The inverter is not in the PU operation mode.
Is PU connector used?
1. Press
. [PU] is lit and the monitor (4 digit LED) displays "1". (When
Pr. 79
= "0" (initial value))
2. Carry out operation from step 6 again.