5. PARAMETERS
5.7 (N) Communication operation parameters
• Real time monitor
Refer to
for the register numbers and monitor items of the real time monitor.
• Parameter
• Fault history
• Model information monitor
NOTE
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
Pr.343 Communication error count
• The communication error occurrence count can be checked.
NOTE
• The communication error count is temporarily stored in the RAM memory. The value is not stored in EEPROM, and so is
cleared to 0 when power is reset or the converter unit is reset.
Pr.
Register
Name
Read/write
Remarks
0 to 999
41000 to
41999
For details on parameter names,
refer to the parameter list (
).
Read/write
The parameter +41000 is the register number.
1000 to
1999
45000 to
45359
For details on parameter names,
refer to the parameter list (
).
Read/write
The parameter +44000 is the register number.
Register
Definition
Read/write
Remarks
40501
Fault record 1
Read/write
Being 2 bytes in length, the data is stored as H00
○○
.
Refer to the lowest 1 byte for the error code. (For details on
error codes, refer to
The fault history is batch-cleared by writing to register 40501.
Set any value as data.
40502
Fault record 2
Read
40503
Fault record 3
Read
40504
Fault record 4
Read
40505
Fault record 5
Read
40506
Fault record 6
Read
40507
Fault record 7
Read
40508
Fault record 8
Read
Register
Definition
Read/write
Remarks
44001
Model (1st and 2nd characters)
Read
The converter model name can be read in ASCII code.
"H20" (blank code) is set for blank area.
Example) For "FR-CC2-N":
H46, H52, H2D, H43, H43, H32, H2D, H4E, H20, H20...H20
44002
Model (3rd and 4th characters)
Read
44003
Model (5th and 6th characters)
Read
44004
Model (7th and 8th characters)
Read
44005
Model (9th and 10th characters)
Read
44006
Model (11th and 12th characters)
Read
44007
Model (13th and 14th characters)
Read
44008
Model (15th and 16th characters)
Read
44009
Model (17th and 18th characters)
Read
44010
Model (19th and 20th characters)
Read
44011
Capacity (1st and 2nd characters) Read
The capacity in the converter unit can be read in ASCII code.
Data read is displayed in increments of 0.1 kW.
"H20" (blank code) is set for blank area.
Example) 450K..." 4500" (H20, H20, H34, H35, H30, H30)
44012
Capacity (3rd and 4th characters)
Read
44013
Capacity (5th and 6th characters)
Read
Parameter
Setting range
Minimum setting range
Initial value
343
(Read-only)
1
0
Содержание FR-CC2-N Series
Страница 61: ...60 3 PRECAUTIONS FOR USE OF THE CONVERTER UNIT 3 4 Checklist before starting operation MEMO ...
Страница 137: ...136 5 PARAMETERS 5 10 Checking parameters changed from their initial values initial value change list MEMO ...
Страница 153: ...152 6 PROTECTIVE FUNCTIONS 6 6 Check first when you have a trouble MEMO ...
Страница 165: ...164 7 PRECAUTIONS FOR MAINTENANCE AND INSPECTION 7 2 Measurement of main circuit voltages currents and powers MEMO ...
Страница 171: ...170 8 SPECIFICATIONS 8 3 Outline dimension drawings MEMO ...