125
5. PARAMETERS
5.7 (N) Communication operation parameters
1
2
3
4
5
6
7
8
9
10
• Normal response (Response message)
• Query message setting
• Content of normal response
The contents in the normal response (
a to d
, including the CRC check) are the same as those in the query messages.
Example) Write 2 (H02) to 41190 (Pr.190) and 8 (H08) to 41191 (Pr.191) of slave address 25
(H19).
Query message
Normal response (Response message)
Read holding register access log (H46 or 70)
• Queries by function codes H03 and H10 are supported. The number and start address of holding registers successfully
accessed by the previous communication are returned. "0" is returned for both the number and start address for queries
other than the function codes above.
• Query message
• Normal response (Response message)
• Query message setting
a. Slave address
b. Function
c. Starting address
d. No. of registers
CRC check
(8 bits)
H10
(8 bits)
H
(8 bits)
L
(8 bits)
H
(8 bits)
L
(8 bits)
L
(8 bits)
H
(8 bits)
Message
Description
a
Slave address
Set the address to send messages to. Setting "0" enables broadcast communication.
b
Function
Set H10.
c
Starting address
Set the holding register address from which to start writing the data.
Starting address = start register address (decimal) - 40001
For example, when starting register address 0001 is set, the data of holding register address 40002
is read.
d
No. of registers
Set the number of holding registers for writing data. Data can be written to up to 125 registers.
e
Byte count
The setting range is H02 to HFA (2 to 250). Set twice the value specified by
d
.
f
Data
Set the amount of data specified by
d
. Write data is output Hi bytes first followed by Lo bytes, and
is arranged as follows: data of start address, data of start 1, data of start 2, and
so forth.
Slave
address
Function
Starting address
No. of registers
Byte count
Data
CRC check
H19
(8 bits)
H10
(8 bits)
H04
(8 bits)
HA5
(8 bits)
H00
(8 bits)
H02
(8 bits)
H04
(8 bits)
H00
(8 bits)
H02
(8 bits)
H00
(8 bits)
H08
(8 bits)
—
(8 bits)
—
(8 bits)
Slave
address
Function
Starting address
No. of registers
CRC check
H19
(8 bits)
H10
(8 bits)
H04
(8 bits)
HA5
(8 bits)
H00
(8 bits)
H02
(8 bits)
—
(8 bits)
—
(8 bits)
a. Slave address
b. Function
CRC check
(8 bits)
H46
(8 bits)
L
(8 bits)
H
(8 bits)
a. Slave address
b. Function
c. Starting address
d. No. of points
CRC check
(8 bits)
H46
(8 bits)
H
(8 bits)
L
(8 bits)
H
(8 bits)
L
(8 bits)
L
(8 bits)
H
(8 bits)
Message
Description
a
Slave address
Set the address to send messages to. Broadcast communication is not possible. (Invalid when "0"
is set.)
b
Function
Set H46.
Содержание FR-CC2-N Series
Страница 61: ...60 3 PRECAUTIONS FOR USE OF THE CONVERTER UNIT 3 4 Checklist before starting operation MEMO ...
Страница 137: ...136 5 PARAMETERS 5 10 Checking parameters changed from their initial values initial value change list MEMO ...
Страница 153: ...152 6 PROTECTIVE FUNCTIONS 6 6 Check first when you have a trouble MEMO ...
Страница 165: ...164 7 PRECAUTIONS FOR MAINTENANCE AND INSPECTION 7 2 Measurement of main circuit voltages currents and powers MEMO ...
Страница 171: ...170 8 SPECIFICATIONS 8 3 Outline dimension drawings MEMO ...