Precautions for use of the inverter
Countermeasures against deterioration of the 400 V class motor insulation
FR-A800
3 - 19
3.5
Countermeasures against deterioration of the 400 V class
motor insulation
In the PWM type inverter, a surge voltage attributable to wiring constants is generated at the motor
terminals. Especially in a 400 V class motor, the surge voltage may deteriorate the insulation. When
the 400 V class motor is driven by the inverter, consider the following countermeasures:
Countermeasures (With induction motor)
It is recommended to take one of the following countermeasures:
●
Rectifying the motor insulation and limiting the PWM carrier frequency according to the wiring
length
For the 400 V class motor, use an
insulation-enhanced motor.
Specifically:
–
Order a "400 V class inverter-driven insulation-enhanced motor".
–
For the dedicated motor such as the constant-torque motor and low-vibration motor, use an
"inverter-driven dedicated motor".
–
Set Pr. 72 "PWM frequency selection" as indicated below according to the wiring length.
●
Suppressing the surge voltage on the inverter side
–
For the FR-A840-01800(55K) or lower, connect the surge voltage suppression filter (FR-ASF-H/
FR-BMF-H) to the output side.
–
For the FR-A840-02160(75K) or higher, connect the sine wave filter (MT-BSL/BSC) to the output
side.
Countermeasures (With PM motor)
When the wiring length exceeds 50 m, set "9" (6 kHz) or less in Pr. 72 "PWM frequency selection".
Wiring length
50 m or shorter
50 m to 100 m
Longer than 100 m
Pr. 72 "PWM frequency selection"
15 (14.5 kHz)
9 (9 kHz)
4 (4 kHz)
Tab. 3-14:
Setting of Pr. 72 according to the wiring length
NOTES
For the details of Pr. 72 "PWM frequency selection", refer to page 5-227. (When using an optional
sine wave filter (MT-BSL/BSC), set "25" (2.5 kHz) in Pr. 72.)
For the details of the surge voltage suppression filter (FR-ASF-H/FR-BMF-H) and the sine wave filter
(MT-BSL/BSC), refer to the Instruction Manual of each option.
A surge voltage suppression filter (FR-ASF-H/FR-BMF-H) can be used under V/F control and
Advanced magnetic flux vector control.
A sine wave filter (MT-BSL/BSC) can be used under V/F control. Do not use the filters under differ-
ent control modes.
The carrier frequency is limited during PM sensorless vector control. (Refer to page 5-227.)
Содержание FR-A820-00046 (0.4K)
Страница 2: ......
Страница 4: ......
Страница 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Страница 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Страница 1110: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1188: ...EC Declarations of Conformity Appendix A 48 A 7 EC Declarations of Conformity A 7 1 FR A820 FR A840 FR A842 series ...
Страница 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1190: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Страница 1192: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1194: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1196: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Страница 1198: ...EC Declarations of Conformity Appendix A 58 ...
Страница 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Страница 1200: ...EC Declarations of Conformity Appendix A 60 ...
Страница 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Страница 1202: ...EC Declarations of Conformity Appendix A 62 ...
Страница 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Страница 1204: ...EC Declarations of Conformity Appendix A 64 ...
Страница 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Страница 1206: ...EC Declarations of Conformity Appendix A 66 ...
Страница 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Страница 1208: ...EC Declarations of Conformity Appendix A 68 ...
Страница 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Страница 1210: ...EC Declarations of Conformity Appendix A 70 ...
Страница 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Страница 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Страница 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Страница 1214: ...EC Declarations of Conformity Appendix A 74 ...
Страница 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Страница 1216: ...EC Declarations of Conformity Appendix A 76 A 7 3 Frequency inverters with option unit FR A8NP ...
Страница 1217: ......