Precautions for use of the inverter
Electro-magnetic interference (EMI) and leakage currents
FR-A800
3 - 9
3.1.3 Built-in
EMC
filter
This inverter is equipped with a built-in EMC filter (capacitive filter) and a common mode choke. Those
filters are effective in reducing air-propagated noise on the input side of the inverter.
To enable the EMC filter, fit the EMC filter ON/OFF connector to the ON position. The FM type is initially
set to "disabled" (OFF), and the CA type to "enabled" (ON).
The input side common mode choke, which is built in the FR-A820-03160(55K) or lower and FR-A840-
01800(55K) or lower inverter, is always enabled regardless of the EMC filter ON/OFF connector setting.
I002808E
Fig. 3-7:
Built-in EMC filter
FILTER
OFF
ON
FILTER
OFF
ON
FILTER
OFF
ON
FILTER
OFF
ON
FILTER
FILTER
OFF
ON
FILTER
FILTER
OFF
ON
EMC filter ON
EMC filter OFF
EMC filter
ON/OFF
connector
FR-A820-00046(0.4K),
00077(0.75K)
FR-A820-00105(1.5K) to 00250(3.7K)
FR-A840-00126(3.7K) or lower
FR-A820-00046(0.4K) to
00250(3.7K)
FR-A840-00023(0.4K) to
00126(3.7K)
FR-A820-00340(5.5K) to
00630(11K)
FR-A840-00170(5.5K) to
00380(15K)
FR-A820-00770(15K) to
01250(22K)
FR-A840-00470(18.5K),
00620(22K)
FR-A820-00770(15K) or higher
FR-A840-00470(18.5K) or higher
EMC filter OFF
EMC filter ON
EMC filter OFF
EMC filter ON
EMC filter OFF
EMC filter ON
FR-A820-01540(30K) or higher
FR-A840-00770(30K) or higher
FR-A820-00046(0.4K),
00077(0.75K)
FR-A820-00340(5.5K) to 00630(11K)
FR-A840-00170(5.5K) to 00380(15K)
Содержание FR-A800
Страница 2: ......
Страница 4: ......
Страница 22: ...Contents XVIII ...
Страница 30: ...Related manuals Introduction 1 8 ...
Страница 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Страница 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 934: ...Check first when you have a trouble Protective functions 6 46 ...
Страница 954: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1030: ...EC Declarations of Conformity Appendix A 46 A 5 EC Declarations of Conformity A 5 1 Low Voltage Directive ...
Страница 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Страница 1032: ...EC Declarations of Conformity Appendix A 48 ...
Страница 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1034: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Страница 1036: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1038: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1040: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1041: ......