50
Operation panel (FR-DU07)
4.2.3
Operation lock (Press [MODE] for an extended time (2s))
· Set "10 or 11" in
Pr. 161
, then press
for 2s to make the setting dial and key operation invalid.
· When the setting dial and key operation is made invalid,
appears on the operation panel.
When the setting dial and key operation is invalid,
appears if the setting dial or key operation is
performed. (When the setting dial or key operation is not performed for 2s, the monitor display appears.)
· To make the setting dial and key operation valid again, press
for 2s.
Operation using the setting dial and key of the operation panel can be made invalid to prevent parameter change,
and unexpected start or frequency setting.
POINT
Set "10 or 11" (key lock mode valid) in
Pr.161 Frequency setting/key lock operation selection
.
Functions valid even in the operation lock status
Stop and reset with
.
CAUTION
Release the operation lock to release the PU stop by key operation.
1.
Screen at powering on
The monitor display appears.
Display
Operation
PU indication is lit.
2.
Press to choose the PU
operation mode.
3.
Press to choose the parameter
setting mode.
Flicker
···
Parameter setting complete!!
7.
Press to set.
5.
Press to read the currently set value.
4.
Turn until appears.
The parameter
number read
previously
appears.
8.
Press for 2s to show the key lock mode.
Press for 2s.
(
Pr. 161
)
" " (initial value) appears.
6.
Turn to change it to the setting
value " ".
Содержание FR-A741-11K
Страница 7: ...MEMO ...
Страница 216: ...209 MEMO ...