Shortest acceleration/deceleration and optimum acceleration/deceleration
(automatic acceleration/deceleration) [Pr. 61 to 63, 292, 293]
(A700)(E700)
The inverter operates in the same conditions as when
appropriate values are set in each parameter even if
acceleration/deceleration time and V/F pattern are not set. This
function is useful when you just want to operate, etc. without
fine parameter setting.
Even if automatic acceleration/deceleration mode is selected,
inputting the JOG signal (Jog operation) or RT signal (second
function selection) or X9 signal (third function selection) during
an inverter stop will switch to the normal operation and give
priority to Jog operation or second and third function selection.
Note that JOG and RT signal input is invalid even if JOG signal
and RT signal are input during operation in automatic
acceleration/deceleration mode.
When PID control or load torque high speed frequency control
is selected, optimum acceleration/deceleration is invalid.
A700 E700
[
Pr.
]
Name
Initial
Value
Setting Range
Description
Available
Inverters
61
Reference current
9999
55K or less 0 to 500A Set the reference current during shortest/
optimum acceleration/deceleration.
{
{
75K or more 0 to 3600A
9999
Rated inverter output current value is
reference
62
Reference value at
acceleration
9999
0 to 220%
0 to 200%
Set the limit value/optimum value during
shortest/optimum acceleration.
{
{
9999
Shortest acceleration/deceleration: 150% is a
limit value
Optimum acceleration/deceleration: 100% is
an optimum value
63
Reference value at
deceleration
9999
0 to 220%
0 to 200%
Set the limit value /optimum value during
shortest/optimum deceleration.
{
{
9999
Shortest acceleration/deceleration: 150% is a
limit value
Optimum acceleration/deceleration: 100% is
an optimum value
292
Automatic
acceleration/
deceleration
0
0
Normal Mode
{
{
1
Shortest acceleration/deceleration (without
brake)
11
Shortest acceleration/deceleration (with brake)
3
Optimum acceleration/deceleration
—
5
,
6
Elevator mode1, 2 (refer to page 249)
7
,
8
Brake sequence mode 1, 2 (refer to page 399)
{
293
Acceleration/
deceleration
individual operation
selection
0
0
Both acceleration and deceleration are made
in the shortest (optimum) acceleration/
deceleration mode
{
{
1
Only acceleration is made in the shortest
(optimum) acceleration/deceleration mode
2
Only deceleration is made in the shortest
(optimum) acceleration/deceleration mode