PARAMETER
PARAMETER
PA
R
A
M
E
T
E
R
2
2.1.4
FR-D700
In the initial setting, only the simple mode parameters are
displayed. Set [
Pr. 160 User group read selection
] as required.
•
indicates simple mode parameters.
• The parameters marked with
in the table allow
its setting to be changed during operation even if 0
(initial value) is set in [
Pr. 77 Parameter write selection
]
• These instruction codes are used for parameter read
and write by using Mitsubishi inverter protocol with the
RS-485 communication.
• Symbols in the control mode-based correspondence table
indicate the following;
{
: Usable parameter
×
: Unusable parameter
• Symbols in the parameter copy, parameter clear, and all
parameter clear columns indicate the following;
{
: Valid
×
: Invalid
[Pr. ]
Name
Initial
Value
Setting
Range
Remarks
160
User group read
selection
9999
9999
Only the simple mode parameters can be displayed.
0
Simple mode+extended mode parameters can be displayed.
F
u
nc
ti
on
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial Value
Refer to
Page
[Pr.]
Instruction Code
Control Mode-based
Correspondence Table
P
ara
met
e
r
Co
py
P
ara
met
e
r
Cle
a
r
Al
l P
ara
met
e
r
Cle
a
r
R
ead
Wri
te
Ext
end
ed
V/F control
General-purpose
magnetic-flux
vector control
B
a
si
c f
u
n
ct
ion
s
0
Torque boost
0 to 30%
0.1%
6/4/3%
0
00
80
0
{
×
{
{
{
1
Maximum frequency
0 to 120Hz
0.01Hz
120Hz
1
01
81
0
{
{
{
{
{
2
Minimum frequency
0 to 120Hz
0.01Hz
0Hz
2
02
82
0
{
{
{
{
{
3
Base frequency
0 to 400Hz
0.01Hz
60Hz
3
03
83
0
{
×
{
{
{
4
Multi-speed setting (high speed)
0 to 400Hz
0.01Hz
60Hz
4
04
84
0
{
{
{
{
{
5
Multi-speed setting (middle speed)
0 to 400Hz
0.01Hz
30Hz
5
05
85
0
{
{
{
{
{
6
Multi-speed setting (low speed)
0 to 400Hz
0.01Hz
10Hz
6
06
86
0
{
{
{
{
{
7
Acceleration time
0 to 3600s
0.1s
5/10s
7
07
87
0
{
{
{
{
{
8
Deceleration time
0 to 3600s
0.1s
5/10s
8
08
88
0
{
{
{
{
{
9
Electronic thermal O/L relay
0 to 500A
0.01A
Rated inverter
current
9
09
89
0
{
{
{
{
{
DC injec
tion
brak
e
10
DC injection brake operation frequency
0 to 120Hz
0.01Hz
3Hz
10
0A
8A
0
{
{
{
{
{
11
DC injection brake operation time
0 to 10s
0.1s
0.5s
11
0B
8B
0
{
{
{
{
{
12
DC injection brake operation voltage
0 to 30%
0.1%
4%
12
0C
8C
0
{
{
{
{
{
-
13
Starting frequency
0 to 60Hz
0.01Hz
0.5Hz
13
0D
8D
0
{
{
{
{
{
-
14
Load pattern selection
0 to 3
1
0
14
0E
8E
0
{
×
{
{
{
JO
G
operat
ion
15
Jog frequency
0 to 400Hz
0.01Hz
5Hz
15
0F
8F
0
{
{
{
{
{
16
Jog acceleration/deceleration time
0 to 3600s
0.1s
0.5s
16
10
90
0
{
{
{
{
{
-
17
MRS input selection
0, 2, 4
1
0
17
11
91
0
{
{
{
{
{
-
18
High speed maximum frequency
120 to 400Hz
0.01Hz
120Hz
18
12
92
0
{
{
{
{
{
-
19
Base frequency voltage
0 to 1000V, 8888, 9999
0.1V
9999
19
13
93
0
{
×
{
{
{
Ac
celerat
ion/
decelerat
ion t
ime
20
Acceleration/deceleration reference
frequency
1 to 400Hz
0.01Hz
60Hz
20
14
94
0
{
{
{
{
{
St
a
ll
prevent
ion
22
Stall prevention operation level
0 to 200%
0.1%
150%
22
16
96
0
{
{
{
{
{
23
Stall prevention operation level
compensation factor at double speed
0 to 200%, 9999
0.1%
9999
23
17
97
0
{
{
{
{
{
M
u
lti-s
p
ee
d
se
tt
in
g
24
Multi-speed setting (speed 4)
0 to 400Hz, 9999
0.01Hz
9999
24
18
98
0
{
{
{
{
{
25
Multi-speed setting (speed 5)
0 to 400Hz, 9999
0.01Hz
9999
25
19
99
0
{
{
{
{
{
26
Multi-speed setting (speed 6)
0 to 400Hz, 9999
0.01Hz
9999
26
1A
9A
0
{
{
{
{
{
27
Multi-speed setting (speed 7)
0 to 400Hz, 9999
0.01Hz
9999
27
1B
9B
0
{
{
{
{
{
-
29
Acceleration/deceleration pattern
selection
0, 1, 2
1
0
29
1D
9D
0
{
{
{
{
{
-
30
Regenerative function selection
0, 1, 2
1
0
30
1E
9E
0
{
{
{
{
{