Special operation
Parameter
6 - 520
6.24.7
Traverse function (Pr. 592 to Pr. 597)
Traverse operation which varies the amplitude of the frequency in a constant cycle can be per-
formed. This function of the is designed specifically for use in yarn-winding applications in the
textile industry.
When "1" or "2" is set in Pr. 592 "Traverse function selection", turning on the traverse operation
signal (X37) makes the traverse function valid.
Set "37" in any of Pr. 178 to Pr. 189 "Input terminal function selection" and assign the X37 signal
to the external terminal. When the X37 signal is not assigned to the input terminal, the traverse
function is always valid (X37-ON).
Pr. No.
Name
Initial
Value
Setting
Range
Description
Parameters referred to
Refer to
Section
592
Traverse function
selection
0
0
Traverse function invalid
1
2
7
8
29
178–189
Maximum
frequency
Minimum
frequency
Acceleration time
Deceleration time
Acceleration/
deceleration
pattern selection
Input terminal
function selection
1
Traverse function is valid only in the
external operation mode
2
Traverse function is valid independ-
ently of operation mode
593
Maximum amplitude
amount
10%
0–25%
Amplitude amount during traverse
operation
594
Amplitude
compensation amount
during deceleration
10%
0–50%
Compensation amount at the time of
amplitude inversion (acceleration
→
deceleration)
595
Amplitude
compensation amount
during acceleration
10%
0–50%
Compensation amount during ampli-
tude inversion operation
(deceleration
→
acceleration)
596
Amplitude
acceleration time
5s
0.1–3600s
Acceleration time during traverse
operation
597
Amplitude
deceleration time
5s
0.1–3600s
Deceleration time during traverse
operation
I001252E
Fig. 6-261:
Traverse function
Output
frequency
Traverse operation
Time [s]
ON
ON
STF (STR)
X37
f0: set frequency
f1: amplitude amount from
the set frequency
(f0
×
Pr. 593/100)
f2: compensation amount
at transition from
acceleration to
deceleration
(f1
×
Pr. 594/100)
f3: compensation amount
at transition from
deceleration to
acceleration
(f1
×
Pr. 595/100)
t1: time from acceleration
during traverse
operation
(time from (f0 + f1)
to (f0
−
f1) (Pr. 597)
t2: time from deceleration
during traverse
operation
(time from (f0
−
f1)
to (f0 + f1) (Pr. 596)
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......