Parameter
Selection of operation mode and operation location
FR-A700 EC
6 - 431
Controllability through communication
Oper-
ation
Loca-
tion
Condition
(Pr. 551)
Command
Operation Mode
PU operation
External
operation
External/PU
combined
operation
mode 1
(Pr. 79 = 3)
External/PU
combined
operation
mode 2
(Pr. 79 = 4)
NET operation
(when RS-485
terminals are
used)
NET operation
(when
communica-
tion option is
used)
Control by RS-485 communic
ation from PU connector
or operation from the USB connector
2
(PU
connector)
or
3
(USB
connector)
Run command
(start, stop)
✔
✔
Running frequency
setting
✔
—
✔
—
—
Monitor
✔
✔
✔
✔
✔
Parameter write
✔
—
✔
✔
—
Parameter read
✔
✔
✔
✔
✔
Inverter reset
✔
✔
✔
✔
✔
Except for 2
(3)
Run command
(start, stop)
Running frequency
setting
—
—
—
—
—
Monitor
✔
✔
✔
✔
✔
Parameter write
—
—
—
—
—
Parameter read
✔
✔
✔
✔
✔
Inverter reset
✔
✔
✔
✔
✔
Control by communication from
inverter RS-485 terminals
1
(RS-485
terminal)
Run command
(start, stop)
✔
—
—
✔
—
Running frequency
setting
✔
—
✔
—
—
Monitor
✔
✔
✔
✔
✔
Parameter write
✔
—
✔
✔
—
Parameter read
✔
✔
✔
✔
✔
Inverter reset
✔
✔
✔
✔
✔
Except for 1
Run command
(start, stop)
—
—
—
—
✔
—
Running frequency
setting
—
—
—
—
✔
—
Monitor
✔
✔
✔
✔
✔
✔
Parameter write
—
—
—
—
✔
—
Parameter read
✔
✔
✔
✔
✔
✔
Inverter reset
—
—
—
—
✔
—
Tab. 6-126:
Functions in the single operation modes (1)
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......