74
Compatible plug-in options
6 APPENDIX
6.1 Compatible plug-in options
Compatible plug-in options are listed below.
6.2 Differences from the standard inverter
The following functions are added or deleted in the FR-A700-A1 series, compared to the FR-A700 series.
Name
Type
Name
Type
Vector control
FR-A7AP
Bipolar analog output/high resolution analog
input/motor thermistor interface
FR-A7AZ
Vector control/encoder pulse dividing output
FR-A7AL
CC-Link communication
FR-A7NC
16-bit digital input
FR-A7AX
L
ON
W
ORKS
communication
FR-A7NL
Digital output/extension analog output
FR-A7AY
PROFIBUS-DP communication
FR-A7NP
Relay output
FR-A7AR
FL-remote communication
FR-A7NF
Function
Application to FR-A700-A1 series
Adjustable 5 points V/F
Pr. 100 to Pr. 109
are deleted.
Bypass-inverter switchover function
Pr. 139
is deleted.
Pr. 135 to Pr. 138
are changed to dancer control function parameters.
Stop-on contact control/load torque high speed frequency
control
Pr. 270 to Pr. 276
are changed to dancer control function parameters.
Brake sequence function
Pr. 282 to Pr. 284
are deleted.
Pr. 278 to Pr. 281
are changed to dancer control function parameters.
Simple position control
Pr. 419, Pr. 482 to Pr. 494
are deleted.
Pr. 464 to Pr. 481
are changed to dancer control function parameters.
Position control
Pr. 420 to Pr. 427, Pr. 429, Pr. 430
are deleted.
Orientation control
Pr. 350 to Pr. 358, Pr. 360 to Pr. 366, Pr. 393, Pr. 396 to Pr. 399
are deleted.
Encoder feedback control
Pr. 367, Pr. 368
are deleted.
Energy saving monitor function
Pr. 891 to Pr. 899
are deleted.
Stop selection
Pr. 250
is deleted.
First cushion voltage/time for restart
Pr. 163, Pr. 164
are deleted.
Monitor
Pr. 52
setting range
"26, 27, 40 to 45, 62 to 65" are added. "50, 51" are deleted. "39, 46" are
used for dedicated function monitors.
Pr. 54, Pr. 158
setting range
"39 to 44" are added, "50, 52, 53" are deleted. "46" is used for dedicated
function monitor.
Applied motor
Pr. 71, Pr. 450
setting range
"2" is deleted.
PID control
Pr. 128
setting range
"40 to 41" are added, "20, 21" are deleted.
Pr. 131 to Pr. 133
setting range "0 to 100%" was changed to "400 to 600%."
Pr. 575
initial value "1s" was changed to "9999".
Input terminal function selection
Setting range
"30, 32 to 35, 51 to 56, 83 to 90, 93" are added. "15, 19, 74" are deleted.
Output terminal function selection
Setting range
"50 to 54" are added. "17 to 20, 120" are deleted.
Override
Setting range "0 to 200%" was changed to "0 to 1000%."
Automatic acceleration/deceleration
Pr. 292
setting range
"7, 8" are deleted.
Dancer control/Winding diameter compensation function/
Tension control function
Pr. 702 to Pr. 704, Pr. 706 to Pr. 734, Pr. 737 to Pr. 799
are added.
Regeneration avoidance function
Pr. 882
setting range
"3" is added.
REMARKS
Functions not mentioned above are the same as FR-A700 series standard inverter.
Refer to FR-A700 series catalog or instruction manual for general specifications.