62
Details of the tension control
(3) Taper ratio input
The input method of the taper ratio can be set by the following parameters.
4.6.3
Inertia compensation function (Pr. 713 to Pr. 716, X57 signal, X58 signal, X59 signal)
(1) Control block diagram
Pr. 787
Pr. 785
Pr. 733
Taper setting
0 to 100%
Setting value of
Pr. 787
9999
2
Terminal 4 input
1, 9999
3
Terminal 2
4
Terminal 4
5
Terminal 1
6
Terminal 6
9999
No function
Parameter
Number
Name
Setting Range
Setting
Increments
Initial
Value
Remarks
713
Initial inertia moment
0 to 500kg · m
2
0.01kg · m
2
0kg · m
2
714
Roll width
0 to 5000mm
1mm
0mm
715
Material specific gravity
0 to 20g/cm
3
0.001g/cm
3
0g/cm
3
716
Inertia compensation
cushion time
0 to 360s
0.01s
0s
Load moment
of inertia
X59
Pr. 757 Pr. 759
X59
Pr. 756 Pr. 758
X57
Acceleration
signal
X58
Deceleration
signal
Torque limit
Pr. 22
Cushion for inertia
compensation
Pr. 716
Inertia
compensation
Z
2
Pr. 20
(
Pr. 721
/present winding diameter)
9.55 acceleration time
Z
2
Pr. 20
(
Pr. 721
/present winding diameter)
9.55 deceleration time