![Mitsubishi Electric CR800-D Series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/mitsubishi-electric/cr800-d-series/cr800-d-series_user-manual_238858077.webp)
When consumption occurred/abnormality detected 75
(2) Timing belt
Error number
C.713n
Error message
Timing belt replacement period
RT ToolBox3 predictive
maintenance message
The timing belt (Jn axis) consumption degree exceeded the warning number of
days remaining. Please check the details and prepare for timing belt replacement.
Measures
Replace the timing belt. After that, reset the consumption degree.
For details of the timing belt and replacement procedure, refer to "5. Maintenance and
Inspection" in the separate volume, "Instruction Manual/Robot Arm Setup &
Maintenance".
For reset method, refer to "11.2 Maintenance Reset"..
Error number
C.713n
Error message
Timing belt replacement period
RT ToolBox3 predictive
maintenance message
The timing belt (Jn axis) consumption degree exceeded 100%.
Timing belt replacement is recommended.
Measures
Replace the timing belt. After that, reset the consumption degree.
For details of the timing belt and replacement procedure, refer to "5. Maintenance and
Inspection" in the separate volume, "Instruction Manual/Robot Arm Setup &
Maintenance".
For reset method, refer to "11.2 Maintenance Reset".
10.1.2. Overhaul parts
(1) Reduction gear
(* n in the table indicates the axis numbers (1 to 6).
Error number
C.714n
Error message
Overhaul period (decelerator)
RT ToolBox3 predictive
maintenance message
The gear (Jn axis) consumption degree exceeded the warning number of days
remaining. Please check the details and prepare for overhaul.
Measures
Perform overhaul of the robot body.
For selection of replacement parts and overhaul implementation timing, consult with
our service affiliated company.
When overhaul is performed, perform reset.
For reset method, refer to "11.2 Maintenance Reset".
Error number
C.714n
Error message
Overhaul period (decelerator)
RT ToolBox3 predictive
maintenance message
The gear (Jn axis) consumption degree exceeded 100%.
Overhaul is recommended.
Measures
Perform overhaul of the robot body.
For selection of replacement parts and overhaul implementation timing, consult with
our service affiliated company.
After overhaul, perform reset.
For reset method, refer to "11.2 Maintenance Reset".
Содержание CR800-D Series
Страница 2: ......
Страница 7: ... Revisions Revision Date Instruction Manual No Revision Details 2019 04 25 BFP A3663 First print ...
Страница 25: ...Basic specifications 23 MEMO ...
Страница 31: ...Basic specifications 29 MEMO ...
Страница 49: ...Startup and initial settings 47 MEMO ...
Страница 57: ...Consumption degree calculation function 55 MEMO ...
Страница 63: ...Operating information 61 MEMO ...
Страница 91: ...Maintenance 89 MEMO ...
Страница 193: ...Troubleshooting 191 ...
Страница 194: ...Apr 2019 MEE Printed in Japan on recycled paper Specifications are subject to change without notice ...