![Mitsubishi Electric CR800-D Series Скачать руководство пользователя страница 190](http://html.mh-extra.com/html/mitsubishi-electric/cr800-d-series/cr800-d-series_user-manual_238858190.webp)
Troubleshooting 188
16.1.3. Abnormality detection function
If the score exceeded the detection level specified by the parameter "PMWNGDRV", "PMWNGEN1", or
"PMWNGEN2", or if the setting of the dedicated output signal is incorrect, the following warnings will occur.
However, the score warning is limited to those permitted to occur by the "PMRPTSCR" parameter.
For details of countermeasures when error number C.717n, C.718n, or C.719n occurs, refer to "10. When
consumption occurred/abnormality detected".
Error number
Causes of the error and its countermeasures
Upper four
digits
Lower five
digits
C.717n
(n indicates
the axis
numbers
(1 to 6).)
00XYY
X =
Mechanism
number
Error
message
Abnormality detection (reducion gear)
Cause
The sign of failure of reduction gear was detected
Measures
Inspection and replacement of reduction gear is
recommended
C.718n
(n indicates
the axis
numbers
(1 to 6).)
00XYY
X =
Mechanism
number
Error
message
Abnormality detection (encoder data)
Cause
The sign of failure of encoder was detected
Measures
Inspection and replacement of motor and wiring is recommended
C.719n
(n indicates
the axis
numbers
(1 to 6).)
00XYY
X =
Mechanism
number
Error
message
Abnormality detection (encoder com.)
Cause
The sign of failure of encoder was detected
Measures
Inspection and replacement of motor and wiring is recommended
H.6640
99000
Error
message
Illegal parameter (PMSIGDRV)
Cause
The parameter setting is illegal
Measures
Correct the parameter
Error
message
Illegal parameter (PMSIGEN1)
Cause
The parameter setting is illegal
Measures
Correct the parameter
Error
message
Illegal parameter (PMSIGEN2)
Cause
The parameter setting is illegal
Measures
Correct the parameter
Error
message
Illegal parameter (PMRSTENC)
Cause
The parameter setting is illegal
Measures
Correct the parameter
Error
message
Illegal parameter (PMSTPDRV)
Cause
The parameter setting is illegal
Measures
Correct the parameter
"Score" used for judgment of warning occurrence is not the maximum score value of
a day but is instead the real time value.
Caution
Содержание CR800-D Series
Страница 2: ......
Страница 7: ... Revisions Revision Date Instruction Manual No Revision Details 2019 04 25 BFP A3663 First print ...
Страница 25: ...Basic specifications 23 MEMO ...
Страница 31: ...Basic specifications 29 MEMO ...
Страница 49: ...Startup and initial settings 47 MEMO ...
Страница 57: ...Consumption degree calculation function 55 MEMO ...
Страница 63: ...Operating information 61 MEMO ...
Страница 91: ...Maintenance 89 MEMO ...
Страница 193: ...Troubleshooting 191 ...
Страница 194: ...Apr 2019 MEE Printed in Japan on recycled paper Specifications are subject to change without notice ...