Communication parameter
5-469
End code
CTERME11
CTERME12
CTERME13
CTERME14
CTERME15
CTERME16
CTERME17
CTERME18
CTERME19
Integer 9
Specifies the end code of the communication message.
0: CR, 1: CR+LF
Correspond to OPT11 to 19 of COMDEV (OPT11),
(OPT12),
(OPT13),
(OPT14),
(OPT15),
(OPT16),
(OPT17),
(OPT18),
(OPT19)
0,
0,
0,
0,
0,
0,
0,
0,
0
Ethernet packet
specification for
datalink
NETPSPEC
Integer 1
Specifies the specifications for packet reception of the datalink
communication via Ethernet.
0: Old
For reception without use of the end code. The Input
command waits until one packet of data is received. The
data cannot be received correctly when the packet is
divided.
1: New
For reception with use of the end code. The Input command
waits until the end code is received even if the packet is
divided.
0
Ethernet communi-
cation protocol ter-
mination code
NETTERM
Integer 9
Specifies the use of the termination code for the datalink commu-
nication via Ethernet.
The elements 1 to 9 correspond to COM1 to COM9.
0: Disable
1: Enable
0,0,0,0,0,0,0,0,0
GOT port number GOTPORT
Integer 1
Specifies the GOT port number for GOT direct connection.
Match the setting with the GOT port number. When the GOT
default setting is not changed, leave it as is.
5001
For ethernet
NETMODE
Numerical
value 9
Server designation (1: Server, 0: Client)
When the data link is applied by ethernet I/F, setting is neces-
sary.
Correspond to OPT11 to 19 of COMDEV (OPT11),
(OPT12),
(OPT13),
(OPT14),
(OPT15),
(OPT16),
(OPT17),
(OPT18),
(OPT19)
1,
1,
1,
1,
1,
1,
1,
1,
1
NETHSTIP
Character string
9
The IP address of the data communication destination server.
When the data link is applied by ethernet I/F, setting is neces-
sary.
* It is valid if specified as the client by NETMODE only.
Correspond to OPT11 to 19 of COMDEV (OPT11),
(OPT12),
(OPT13),
(OPT14),
(OPT15),
(OPT16),
(OPT17),
(OPT18),
(OPT19)
192.168.0.2 ,
192.168.0.3 ,
192.168.0.4 ,
192.168.0.5 ,
192.168.0.6 ,
192.168.0.7 ,
192.168.0.8 ,
192.168.0.9 ,
192.168.0.10
MXTTOUT
Numerical
value 1
(0 to 32767)
Timeout time for executing real-time external control command
(Multiple of 7.1msec, Set -1 to disable timeout)
-1
Timeout time for
loading a vision-
program
NVJBTOUT
Integer 1
Specify the timeout time for loading a program of a network
vision sensor.
(Unit: seconds, Setting range: 1 to 32767)
90
Initial tag name of
EBRead command
EBRDTAG
Character string
1
Set an initial symbolic tag name (128 characters or less) for the
vision sensor designated in the EBRead command.
This parameter setting value is specified when the tag name is
omitted in the description of the EBRead command.
"Job.Robot. For-
matString"
Parameter
Parameter
name
No. of arrays
No. of characters
Details explanation
Factory setting