background image

Specifications subject to change without notice.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, 

Trade and Industry for service transaction permission.

This manual confers no industrial property rights or any rights of any other kind, nor 
does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held 
responsible for any problems involving industrial property rights which may occur as 
a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation 
      for accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run and 
      other tasks.

•  This product has been manufactured as a general-purpose part for general

industries, and has not been designed or manufactured to be incorporated in a 
device or system used in purposes related to human life.

•  Before using the product for special purposes such as nuclear power, electric power, 

aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric. 

• This product has been manufactured under strict quality control. However

when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.

For safe use

Country/Region Sales office/Tel
USA

MITSUBISHI ELECTRIC AUTOMATION, INC.
500 Corporate Woods Parkway, Vernon Hills, 

IL 60061, U.S.A.
Tel : +1-847-478-2100/+1-847-478-2500 (NC)

Brazil

MITSUBISHI ELECTRIC DO BRASIL 
COMERCIO E SERVICOS LTDA. 
Avenida Adelino Cardana, 293, 21 andar, 
Bethaville, Barueri SP, Brazil 
Tel : +55-11-4689-3000

Germany

MITSUBISHI ELECTRIC EUROPE B.V. 
– German Branch

Mitsubishi-Electric-Platz 1, 40882 
Ratingen, Germany

Tel : +49-2102-486-0

UK

MITSUBISHI ELECTRIC EUROPE B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire, 
AL10 8XB, UK
Tel : +44-1707-28-8780

Italy

MITSUBISHI ELECTRIC EUROPE B.V. 
– Italian Branch
Centro Direzionale Colleoni - Palazzo Sirio, 
Viale Colleoni 7, 20864 Agrate Brianza (MB), Italy
Tel : +39-039-60531/+39-039-6053-342 

Spain

MITSUBISHI ELECTRIC EUROPE, B.V. 
– Spanish Branch

Carretera de Rubi 76-80-AC.420, E-08190 
Sant Cugat del Valles (Barcelona), Spain 
Tel : +34-935-65-3131/+34-935-65-2236 

France

MITSUBISHI ELECTRIC EUROPE B.V.
 – French Branch
25, Boulevard des Bouvets, 92741 
Nanterre Cedex, France
Tel : +33-1-55-68-55-68

Czech Republic  MITSUBISHI ELECTRIC EUROPE B.V. 

Czech Branch
Avenir Business Park, Radicka 751/113e, 
158 00 Praha5, Czech Republic
Tel : +420-251-551-470

Poland

Mitsubishi Electric Europe B.V. Polish Branch
ul. Krakowska 50, 32-083 Balice, Poland
Tel : +48-12-347-65-00

Country/Region Sales office/Tel

Russia 

China

MITSUBISHI ELECTRIC AUTOMATION 
(CHINA) LTD.
Mitsubishi Electric Automation Center, 
No.1386 Hongqiao Road, Shanghai, China
Tel : +86-21-2322-3030

Taiwan

SETSUYO ENTERPRISE CO., LTD.
6F, No.105, Wugong 3rd Road, Wugu District, 
New Taipei City 24889, Taiwan, R.O.C.
Tel : +886-2-2299-2499

Korea

MITSUBISHI ELECTRIC AUTOMATION 
KOREA CO., LTD.

7F~9F, Gangseo Hangang Xi-tower A, 401, 
Yangcheon-ro, Gangseo-Gu, Seoul, 07528, Korea
Tel : +82-2-3660-9530

Singapore

MITSUBISHI ELECTRIC ASIA PTE. LTD, 
307 Alexandra Road, Mitsubishi Electric 
Building, Singapore 159943 
Tel : +65-6473-2308

Thailand

Mitsubishi Electric Factory Automation 
(Thailand) Co., Ltd.
12th Floor, SV.City Building, Office Tower 1, 
No. 896/19 and 20 Rama 3 Road, Kwaeng 
Bangpongpang, Khet Yannawa, 
Bangkok 10120, Thailand
Tel : +66-2682-6522~31

Indonesia

PT. Mitsubishi Electric Indonesia
Gedung Jaya 11th Floor, JL. MH. Thamrin
No.12, Jakarta Pusat 10340, Indonesia

Tel : +62-21-3192-6461

India

Mitsubishi Electric India Pvt. Ltd. 
Gurgaon Head Office
2nd Floor, Tower A & B, Cyber Greens, 
DLF Cyber City, DLF Phase - III, 
Gurgaon - 122002, Haryana, India
Tel : +91-124-4630300

Australia

MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD.
348 Victoria Road PO BOX11, Rydalmere, 
N.S.W 2116, Australia 
Tel : + 61-2-9684-7777

Mitsubishi Electric (Russia) LLC
52, bld. 1, Kosmodamianskaya emb., 
115054 Moscow, Russia
Tel : +7-495-721-2070

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品

 本产品中所含有的有害6 物质的名称,含有量,含有部品如下表

所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572

 规定的限量要求以下。 

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 
    26572规定的限量要求。

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

可编程
控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使用标识要求」的表示方式

Side

A

Side

B

JAPANESE

Side

B

ENGLISH

SAFETY PRECAUTIONS

(Read these precautions before using.)

Please read this manual carefully and pay special attention to safety in order
to handle this product properly. Also pay careful attention to safety and handle
the module properly.
These precautions apply only to Mitsubishi equipment. Refer to the user’s
manual of the CPU module to use for a description of the PLC system safety
precautions.
These 

SAFETY PRECAUTIONS

 classify the safety precautions into two

categories: "WARNING" and "CAUTION".

Depending on circumstances, procedures indicated by

 may also

be linked to serious results.
In any case, it is important to follow the directions for usage.
Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.

[DESIGN PRECAUTIONS] 

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS] 

Procedures which may lead to a dangerous condition 
and cause death or serious injury if not carried out 
properly.

Procedures which may lead to a dangerous condition 
and cause superficial to medium injury, or physical 
damage only, if not carried out properly.

• Configure an interlock circuit in a sequence program so that the system operates on the safety 

side using the communication status information in the event the data link falls into a 
communication problem.
Otherwise, erroneous output and malfunction may result in accidents.

• Remote input and output can not be switched ON or OFF when a problem occurs in the remote 

I/O modules. Therefore build an external monitoring circuit that will monitor any input signals that 
could cause a serious accident.

• Do not have control cables and connection cables bundled with or placed near by the main 

circuit and/or power cables. Wire those cables at least 100mm(3.94 inch) away from the main 
circuit and/or power cables. It may cause malfunction due to noise interference.

• Use the module in the status in which any force is not applied on the module, flat cables 

dedicated to CC-Link/LT and flat cables for I/O. 
If a force is applied, wire breakage or failure may be caused.

• Use the module in an environment that meets the general specifications contained in this 

manual. Using this module in an environment outside the range of the general specifications 
could result in electric shock, fire, erroneous operation, and damage to or deterioration of the 
product.

• Do not directly touch the module's conductive parts. Doing so could cause malfunction or trouble 

in the module.

• Perform installation and wiring after disconnecting the power supply at all phases externally. If 

the power is not disconnected at all phases an electric shock or product damage may result.

• Perform correct wiring for the module according to the product's rated voltage and terminal 

arrangement. Connecting to a power supply different from rating or miss-wiring may cause fire, 
product failure or malfunction.

• Make sure foreign objects do not get inside the module, such as dirt and wire chips. It may cause 

fire, product failure or malfunction.

• Do not short-circuit the 24G and +24V terminals. It may result in fire, product failure or 

malfunction.

• Attach a warning label (hazard symbol 417-IEC-5036) concerning the electric shock to the 

location.

[STARTING AND MAINTENANCE PRECAUTIONS] 

[DISPOSAL PRECAUTIONS] 

[TRANSPORTATION AND MAINTENANCE PRECAUTIONS] 

Notification of CE marking

This notification does not guarantee that an entire mechanical module produced
in accordance with the contents of the notification comply with the following
standards. Compliance to EMC standards of the entire mechanical module
should be checked by the user / manufacturer.

Attention

This product is designed for use in industrial applications.

Standards with which this product complies

Type : Programmable Controller (Open Type Equipment) Remote I/O module
Models :  Products manufactured:

from November 1st, 2002 to April 30th, 2006 are compliant with
  EN61000-6-4 and EN61131-2:1994+A11:1996+A12:2000
after May 1st, 2006 are compliant with EN61131-2:2007

For more details please contact the local Mitsubishi Electric sales site.
• Notes for compliance to EMC regulation.

It is necessary to install the CL1 series module in a shielded metal control 
panel.

• Use this product in Zone A

*1

 as defined in EN61131-2.

*1 Zone defined in EN61131-2

Separation defined in EN61131-2 for EMC LVD regulation decided
depending on condition in industrial setting.

Zone C =  Factory mains which is isolated from public mains by dedicated

transformers.

Zone B =  Dedicated power distribution which is protected by secondary 

surge protection. (300 V or less in the rated voltage is 
assumed.)

Zone A =  Local power distribution which is isolated from dedicated power 

distribution by AC/DC converters, isolation transformers, etc. 
(120 V or less in the rated voltage is assumed.)

• Do not touch the terminals when the power is ON. It may cause an electric shock or malfunction.
• Perform cleaning the module after turning OFF the all external power supply for sure. Failure to do so 

may cause failure or malfunction of the modules.

• Do not disassemble or modify the module. Doing so may cause failure, malfunction, injury, or fire.
• The module case is made of resin; do not drop it or subject it to strong shock. A module damage may 

result.

• Make sure to switch all phases of the external power supply OFF before installing or removing the 

module to/from the panel. Failure to do so may cause failure or malfunction of the modules.

• When disposing of this product, treat it as industrial waste.

• During transportation avoid any impact as the module is a precision instrument. Doing so could cause 

trouble in the module.

• If is necessary to check the operation of module after transportation, in case of any impact damage.

Electromagnetic Compatibility 

Standards (EMC)

Remark

EN61000-6-4:2001

Electromagnetic compatibility
-Generic standards - Emission standard
  for  Industrial environment

Compliance with all relevant aspects of 
the standard.
(Radiated Emissions and Mains 
Terminal Voltage Emissions)

EN61131-2:1994/A11:1996/A12:2000

Programmable controllers
 -Equipment requirements and tests

Compliance with all relevant aspects of 
the standard.
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• Damped oscillatory wave

EN61131-2: 2007

Programmable controllers
 -Equipment requirements and tests

Compliance with all relevant aspects of 
the standard.

EMI

• Radiated Emission
• Conducted Emission

EMS

• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field

1.

Outline of Product

This product is a cable type composite I/O module connected to CC-Link/LT. 
This product has one input point (24 V DC) and one output point (transistor
output).

2.

Name and Setting of Each Part

3.

Cautions on Handling

3.1 Handling of flat cable for I/O

The cable length from the module to a sensor shall be within 3m(9'10").
Measure the cable outside the module, and confirm that the driving voltage for
the used sensor is assured.

Input/output is ON: Lit
Input/output is OFF: Extinguished

Attach it with
this area facing
upward.

Status indicator LEDs

LED name
PW

L RUN

Operation
Lit while the
power is supplied.
Lit while normal
operation is
executed.

Blue

40 20

 

10

 

 

 

4   2   1

HLD

DIP switch
(Remove the switch cover
when setting the DIP switch.)

DIP switch assignment

Switch cover
(Make sure to attach the
switch cover after setting
the DIP switch.)

Input

operation

indicator

LED

Output

operation

indicator

LED

Flat cable dedicated
to CC-Link/LT

Flat cable for I/O

ON

Black

White

Brown

Name

Description

Status indicator 
LED

PW

ON while the power is supplied.

L RUN ON while normal operation is executed.

I/O operation 
indicator LED

ON while the input or output is ON.
Extinguished while the input or output is OFF.

Flat cable 
dedicated to CC-
Link/LT

24G

Connector for CC-Link/LT communication line/
module power supply

DB

DA

+24V

Flat cable for I/O

Blue

24G

Black

X0

White

Y0

Brown +24V

DIP switch

Set the 10's digit of the station No. using "STATION NO. 10", 
"STATION NO. 20" and "STATION NO. 40". Set the 1's digit of 
the station No. using "STATION NO. 1", "STATION NO. 2", 
"STATION NO. 4" and "STATION NO. 8".
Factory default = All bits are OFF.
Make sure to set the station No. in the range from 1 to 64.

HLD

Holds the output (when an error has occurred).
ON: Holds the output.
OFF: Clears the output.

0

X0 input operation

indicator LED

Y0 output operation

indicator LED

0

40

20

10

8

4

2

1

10's digit

1's digit

Station

No.

32

ON

OFF

ON

OFF

ON

OFF

OFF

Example: When setting the station No. to "32", set the
                DIP switch as follows.

• Input

• Output

If the diameter of the I/O equipment connection cable is equivalent to the
diameter of the flat cable for I/O of this module, connectors dedicated to
CC-Link/LT can be used for connection.

3.2 Handling of cable

Do not bend the cable within 30 mm (1.18") from the module.

Use a crimp-style terminal in a status in which no force is applied on the
cable.

3.3 Mounting with the CL1-HLD (module holder)

Refer to the figures below for details on mounting or removing the remote 
I/O module when used with the CL1-HLD.

4.

Wiring

4.1 External wiring

The input and output terminals of the CL1XY2-DT1D5S operate while
using the power supplied from the interface.
When connecting a sensor to the input terminal, use a sensor of the NPN
open collector transistor type.
The output wiring is fixed to the sink output.

Crimp-style connection device with
insulator or closed end connection 
device

Sensor,
switch, etc.

Crimp-style connection device with
insulator or closed end connection 
device

Lamp,
solenoid, etc.

Input
equipment

Connector dedicated to CC-Link/LT

Output
equipment

Wire diameter: AWG18 (34/0.18)

30mm(1.19")

30mm(1.19")

1)Fit the remote 

I/O module in 
a corner of the 
CL1-HLD.

2)Press down b) 

while holding 
a).

1)Insert a screwdriver into either a, b, c, or d.
2)Pry the remote I/O module from the 
   holder using the screwdriver.

Mount

Dismount

CL1-HLD

Remote 

I/O 

module

a)

b)

a

b

c

d

I/O wiring

4.2 Connection to sensor

• When using a two-wire type sensor

y

When using a three-wire type sensor 

Replace * in the figure with the used input No.

Notes:
*1 Bleeder resistor

When connecting a two-wire type sensor or input equipment having parallel
resistor, select a sensor or equipment whose leakage current is 1.7 mA or
less.
If the leakage current is more than 1.7 mA, connect a bleeder resistor
obtained in the following calculation formula.

Circuit image

R (k

) < 1.7 (mA) / Leakage current (mA) - 1.7 (mA) 

× 

5.6 (k

)

The power capacity W of the bleeder resistor R is as follows:
W = (Input voltage)

2

/R

• Make sure that both the ON and OFF time of the input signal are 1.5ms or 

more.

5.

Specifications

5.1 General specifications

0.5A

0.5A

24G

DA
DB

+24V

DC DC

Y0

L

X0

+24V

24G

R

R

R

CL1XY2-DT1D5S

Isolation

Flat cable
dedicated
to CC-Link/LT

Flat cable
for I/O

Internal
circuit

Bleeder resistor *1

Connected to +24 V 

cable

Sensor (NPN)

Sensor (NPN)

X  *

24G

X  *

24G

Connected to +24 V 

cable

Detection

circuit

Detection

circuit

R

24V DC

Leakage
current

Input impedance
5.6 k

1.7 mA or less

R: Bleeder resistor

Sensor

Unit

Detection
circuit

Item

Specification

Ambient 
working 
temperature

0 to 55

°

C (32 to 131

°

F)

Ambient storage 
temperature

-25 to 75

°

C (-13 to 167

°

F)

Ambient 
operating 
humidity

5 to 95%RH: Dew condensation shall not be considered.

Ambient storage 
humidity

5 to 95%RH: Dew condensation shall not be considered.

Notes:

*1 The criterion is shown in IEC61131-2.

*2 The module cannot be used in an environment pressurized above the

atmospheric pressure which can be generated around the altitude of 0 m. If the
module is used in such an environment, it may fail.

*3 The module can be used in any environment even outside the control panel as

far as the requirements of the ambient operating temperature, the ambient
operating humidity, etc. are satisfied.

*4 This indicates the section of the power supply to which the equipment is

assumed to be connected between the public electrical power distribution
network and the machinery within premises. Category 

ΙΙ

 applies to equipment

for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300V is 2500V.

*5 This index indicates the degree of conductive generating substances in the

environment in which the module is used. The degree of contamination 2 indicates
that contamination is caused by generation of only non-conductive substances.
In this degree, however, temporary conduction may be caused by accidental
condensation.

5.2 Input specifications

5.3 Output specifications

Item

Specification

Vibration 
resistance

 (*1)

When intermittent vibration is present

Number 
of times of 
sweep

Frequency

Acceleration

Half amplitude

10 times 
in each of 
X, Y and Z 
directions 
(for 80 
min)

10 to 57 Hz

0.075 mm

57 to 150 Hz

9.8 m/s

2

When continuous vibration is present

Frequency

Acceleration

Half amplitude

10 to 57 Hz

0.035 mm

57 to 150 Hz

4.9 m/s

2

Impact 
resistance

 (*1)

147 m/s

2

, 3 times in each of X, Y and Z directions

Operating 
atmosphere

Corrosive gas shall not be present.

Operating 
altitude

2,000 m (6561'8") or less (*2)

Installation 
place

Inside control panel (*3)

Over-voltage 
category

ΙΙ

 or less (*4)

Degree of 
contamination

2 or less (*5)

Item

Specification

Input method

DC input (using module power supply in common)

Number of input

1 point

Isolation method

Isolation with photocoupler

Rated input voltage

24 V DC

Rated input current

Approx. 4 mA

Operating voltage range

Same as module power supply

Max. simultaneous ON 
input points

100% (at 24 V DC)

ON voltage/ON current

19 V or more/3 mA or more

OFF voltage/OFF current

11 V or less/1.7 mA or less

Input resistance

5.6 k

Response 
time

OFF

ON

1.5 ms or less (at 24 V DC)

ON

OFF

1.5 ms or less (at 24 V DC)

Common wiring method

1 point/1 common (Mutually exclusive output)

Item

Specification

Output method

Transistor output
(using module power supply in common) (sink)

Number of output

1 point

Isolation method

Isolation with photocoupler

Rated load voltage

24 V DC

Operating load voltage 
range

Same as module power supply

Max. load current

0.1 A/point    0.2 A/1 common

Max. inrush current

0.4 A/10 ms

Leakage current at OFF

0.1 mA or less/30 V DC

Max. voltage drop at ON

1 V or less (max.)/0.1 A

5.4 Performance specifications

6.

Outside Dimensions

Response 
time

OFF

ON

1.0 ms or less

ON

OFF

1.0 ms or less 

Surge suppression

Zener diode

Common wiring method

1 point/1 common (Mutually exclusive output)

Internal protection for 
outputs

Internal protection circuit none
Please connect the fuse in the connected load 
outside.

Item

Specification

Item

Specification

Module 
power 
supply

Voltage

20.4 to 28.8 V DC (24 V DC -15% to +20%)
Ripple ratio: Within 5% 

Current 

consumption

40 mA (when all points are ON)
(Current consumption contains neither the input 
current nor the load current.)

Initial current

70 mA

Max. allowable 

momentary power 

failure period

PS1:1 ms

Number of stations 
occupied

4-, 8- or 16-point mode: 1 station

Noise durability

500 Vp-p
Noise width: 1

µ

s Cycle: 25 to 60 Hz

(by noise simulator)

Withstand voltage

500 V AC for 1 min

Isolation resistance

10 M

 or higher between primary area (external 

DC terminal) and secondary area (internal circuit) 
by 500V DC insulation resistance tester

Protection class

IP2X

I/O part connection method

Connection with cable

Module installation method

Can be installed in six directions

Flat cable for I/O (wire 
diameter)

AWG18 (34/0.18)

Mass (weight)

0.07 kg (0.15 lbs)
(including 500 mm (19.69") flat cable dedicated to 
CC-Link/LT and 500 mm (19.69") flat cable for I/O)

Unit: mm(inches)

24G       X0         Y0 

      

 +24V

20(0.79")

65(2.56")

500(19.69")

12(0.48")

500(19.69")

CL1XY2-DT1D5S

CC-Link/LT Remote I/O Module

Please read this manual thoroughly before starting to use the product and 
handle the product properly.

User’s Manual

MODEL

 CL1XY2-DT1D5S

MANUAL Number

 JY997D03801K

Date

 August 2017

Отзывы: