-130-
2
LEV2
Pulse Signal Output and Valve Operation
Output (Phase)
Output State
No.
1
2
3
4
ø
1
ON
OFF OFF
ON
ø
2
ON
ON OFF OFF
ø
3
OFF
ON
ON
OFF
ø
4
OFF OFF ON
ON
LEV Valve Closing and Valve Opening Operations
V
alv
e Opening Angle (Flo
w Rate)
Increased choke range
(80 ~ 100 pulses)
Pulse Count
Full Open
2000 pulses
Valve Closing
Valve Opening
C
A
B
Output pulses change in the following orders when the
Valve is Closed
1
→
2
→
3
→
4
→
1
Valve is Open
4
→
3
→
2
→
1
→
4
*1. When the LEV opening does not change, all output
phases are OFF.
2. When the output opens a phase and stays ON, the
motor will not run smoothly and will clack and
vibrate.
3. When the power source is turned on, a close valve
signal (2200 pulse) is sent to confirm the valve
position, ensuring a starting point of
A
.
4. When the valve is operating smoothly, there will be
no sound or vibrations from the LEV, when opera-
tion goes from point
E
to point
A
, the valve locks
and open phases create a considerable noise.
5. The noise emanates from the driver and can be
easily discerned by placing a screwdriver against it
and then placing your ear against the handle.
D
E
Содержание CITY MULTI PUHY-400YMF-C
Страница 15: ... 12 FANCON board G A board CNFAN CNFC2 CNPOW CNE CNDC1 CN15V1 CNDR1 CNIPM1 ...
Страница 16: ... 13 Y C board SNB board ...
Страница 17: ... 14 RELAY board CNRT2 CNCH CN52C2 CN52F CN51C2 CNOUT2 ...
Страница 19: ... 16 CONT board CNTR SWU2 SWU1 SW3 SW2 CNS1 M NET transmission CNFC1 CN20 Power supply 1 N 3 L1 ...
Страница 20: ... 17 FANCON board CNW CNV CNU CNFC2 ...
Страница 149: ... 146 Motor Compressor G A board Red U V W N P White Black Black Capacitor C2 C3 Red IPM ...
Страница 207: ......
Страница 208: ......
Страница 209: ......