background image

Air-Conditioners For Building Application
INDOOR UNIT

PFFY- P

VKM-E (2)

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing 
the air-conditioner unit.

INSTALLATIONSHANDBUCH

Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.

MANUEL D’INSTALLATION

Avant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil exté-
rieur pour une utilisation sûre et correct.

INSTALLATIEHANDLEIDING

Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het 
installeren van de airconditioner begint.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, prima di installare il condizionatore d’aria leggere attentamente il presente manuale 
ed il manuale d’installazione dell’unità esterna.

MANUAL DE INSTALACIÓN

Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de 
aire acondicionado.

MANUAL DE INSTALAÇÃO

Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade exte-
rior antes de instalar o aparelho de ar condicionado.

PARA O INSTALADOR

PER L’INSTALLATORE

PARA EL INSTALADOR

VOOR DE INSTALLATEUR

POUR L’INSTALLATEUR

FÜR INSTALLATEURE

FOR INSTALLER

ΕΓΧΕΙΡΙΔΙΟ

 

ΟΔΗΓΙΩΝ

 

ΕΓΚΑΤΑΣΤΑΣΗΣ

Για

 

σωστή

 

και

 

ασφαλή

 

χρήση

διαβάστε

 

προσεκτικά

 

αυτό

 

το

 

εγχειρίδιο

καθώς

 

και

 

το

 

εγχειρίδιο

 

εγκατάστασης

 

της

 

εξωτερικής

 

μονάδας

πριν

 

από

 

την

 

εγκατάσταση

 

της

 

μονάδας

 

κλιματιστικού

.

ΓΙΑ

 

ΑΥΤΟΝ

 

ΠΟΥ

 

ΚΑΝΕΙ

 

ΤΗΝ

 

ΕΓΚΑΤΑΣΤΑΣΗ

MONTAJ ELK

İ

TABI

Emniyetli ve do

ğ

ru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve dı

ş

 ünite montaj kılavuzunu 

tamamıyla okuyun.

MONTÖR 

İ

Ç

İ

N

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

Для

 

обеспечения

 

безопасной

 

и

 

надлежащей

 

эксплуатации

 

внимательно

 

прочтите

 

данное

 

руководство

 

и

 

руководство

 

по

 

установке

 

наружного

 

прибора

 

перед

 

установкой

 

кондиционера

.

ДЛЯ

 

УСТАНОВИТЕЛЯ

English (GB)

Deutsch (D)

Français (F)

Nederlands (NL)

Español (E)

Italiano (I)

Ελληνικά

 (GR)

Português (P)

Türkçe (TR)

Русский

 (RU)

Содержание CITY MULTI PFFY-P-VKM-E

Страница 1: ...DE INSTALACIÓN Para un uso seguro y correcto lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado MANUAL DE INSTALAÇÃO Para uma utilização segura e correcta leia atentamente este manual e o manual de instalação da unidade exte rior antes de instalar o aparelho de ar condicionado PARA O INSTALADOR PER L INSTALLATORE PARA EL INSTALADOR VOOR DE INSTALLATEUR PO...

Страница 2: ...rant should leak The cut face punched parts may cause injury by cut etc The installers are requested to wear protective equipment such as gloves etc When installing or relocating or servicing the outdoor unit use only the specified refrigerant R410A to charge the refrigerant lines Do not mix it with any other refrigerant and do not allow air to remain in the lines If air is mixed with the refriger...

Страница 3: ...1 14 1 3 3 Indoor unit installation Fig 3 5 Hook the top of the indoor unit on the indoor unit mounting bracket Use the included wood screws and washer and fasten the indoor unit at 2 loca tions each at the top and the middle of the unit Note Install the indoor unit securely to the wall making sure that there is no gap between the unit and the wall 3 4 Making holes in the wall and floor 3 4 1 Maki...

Страница 4: ...o insulate indoor unit connections Insulate carefully Warning When installing the unit securely connect the refrigerant pipes before start ing the compressor Copper pipe O D mm Flare dimensions øA dimensions mm ø6 35 8 7 9 1 ø9 52 12 8 13 2 ø12 7 16 2 16 6 ø15 88 19 3 19 7 ø19 05 23 6 24 0 A Flare cutting dimensions B C D 90 0 5 øA R 0 4 R 0 8 A 45 2 Fig 4 1 B Refrigerant pipe sizes Flare nut tigh...

Страница 5: ...ghtly downward 1 100 or more so that the drain water flows easily Do not route the drain piping as shown in the examples mark with an X in the figure Fig 5 1 If the drain hose is too short refer to Fig 5 2 to extend the length of the hose If the indoor unit is installed in a high location such as a high rise apartment strong winds may cause the drain water to flow back through the drain hose and l...

Страница 6: ...d etc to ad just the height of the indoor unit If the upper or lower air outlet is blocked the air conditioner will not be able to cool or warm the room well Use a grating with vertical bars etc that has at least 75 open area If the grat ing has horizontal bars or if the open area is less than 75 performance could be reduced When the indoor unit is embedded in a wall built in the time it takes for...

Страница 7: ...bles refer to the outdoor unit installation manual Install a remote controller following the manual supplied with the remote control ler Connect the remote controller s transmission cable within 10 m using a 0 75 mm2 core cable If the distance is more than 10 m use a 1 25 mm2 junction cable 1 MA Remote controller Connect the connector for MA remote controller Non polarized 2 wire DC 9 to 13 V betw...

Страница 8: ...arning Do not use the air conditioner if the insulation resistance is less than 1 0 M 8 2 Test run Using wired remote controller Fig 8 1 1 Turn on the power at least 12 hours before the test run 2 Press the TEST button twice TEST RUN liquid crystal display 3 Press the Mode selection button Make sure that wind is blown out 4 Press the Mode selection button and switch to the cooling or heating mode ...

Страница 9: ...dress board SWC SWC Note Be sure to operate with the main power turned off Description of operation Operation Upper and lower air flow Room temperature and set temperature are dif ferent Upper air flow Room temperature is close to set temperature or thermo off Upper air flow only Upper and lower air flow Normal condition in heating Upper air flow During defrosting op eration start of opera tion th...

Страница 10: ...ct at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Machinery Directive 2006 42 EC Energy related Products Directive 2009 125 EC HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Authorized representative in EU MITSUBISHI EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDE MIDDLE SEX UB8 1QQ U K ...

Отзывы: