A - 9 A - 9
ABOUT THE GENERIC TERMS AND ABBREVIATIONS
Unless otherwise specified, the following generic terms and abbreviations are used in this manual to
describe Type AJ65VBTCU-68DAVN analog-digital converter module.
Generic Term/Abbreviation
Description
GX Developer
Product name of the software package for the MELSEC programmable Controllers.
GX Works2
ACPU
Generic term for A0J2HCPU, A1SCPU, A1SCPUC24-R2, A1SHCPU, A1SJCPU,
A1SJCPU-S3, A1SJHCPU, A1NCPU, A2NCPU, A2NCPU-S1, A3NCPU, A2SCPU,
A2SHCPU, A2ACPU, A2ACPU-S1, A3ACPU, A2UCPU, A2UCPU-S1, A2USCPU,
A2USCHPU-S1, A2USHCPU-S1, A3UCPU and A4UCPU
QnACPU
Generic term for Q2ACPU, Q2ACPU-S1, Q2ASCPU, Q2ASCPU-S1, Q2ASHCPU,
Q2ASHCPU-S1, Q3ACPU, Q4ACPU and Q4ARCPU
QCPU (A mode)
Generic term for Q02CPU-A, Q02HCPU-A and Q06HCPU-A
QCPU (Q mode)
Generic term for Q00JCPU, Q00CPU, Q01CPU, Q02CPU, Q02HCPU, Q06HCPU,
Q12HCPU, Q25HCPU, Q02PHCPU, Q06PHCPU, Q12PHCPU, Q25PHCPU,
Q12PRHCPU, Q25PRHCPU, Q00UJCPU, Q00UCPU, Q01UCPU, Q02UCPU,
Q03UDCPU, Q04UDHCPU, Q06UDHCPU, Q10UDHCPU, Q13UDHCPU,
Q20UDHCPU, Q26UDHCPU, Q03UDECPU, Q04UDEHCPU, Q06UDEHCPU,
Q10UDEHCPU, Q13UDEHCPU, Q20UDEHCPU, Q26UDEHCPU, Q50UDEHCPU and
Q100UDEHCPU.
LCPU
Generic term for L02CPU, L26CPU-BT
Master station
Station that controls the data link system.
One master station is required for each system.
Local station
Station having a programmable controller CPU and the ability to communicate with the
master and other local stations.
Remote I/O station
Remote station that handles bit unit data only. (Performs input and output with external
devices.) (AJ65BTB1-16D, AJ65SBTB1-16D)
Remote device station
Remote station that handles bit unit and word unit data only. (Performs input and output
with external devices, and analog data exchange.)
Remote station
Generic term for remote I/O station and remote device station.
(Controlled by the master station)
Intelligent device station
Station that can perform transient transmission, such as the AJ65BT-R2N (including
local stations).
Master module
Generic term for modules that can be used as the master station.
SB
Link special relay (for CC-Link)
Bit unit information that indicates the module operating status and data link status of the
master station/local station. (Expressed as SB for convenience)
SW
Link special register (for CC-Link)
16 bit unit information that indicates the module operating status and data link status of
the master station/local station. (Expressed as SW for convenience)
RX
Remote input (for CC-Link)
Information entered in bit units from the remote station to the master station.
(Expressed as RX for convenience)
RY
Remote output (for CC-Link)
Information output in bit units from the master station to the remote station. (Expressed
as RY for convenience)
RWw
Remote register (Write area for CC-Link)
Information output in 16-bit units from the master station to the remote device station.
(Expressed as RWw for convenience)
RWr
Remote register (Read area for CC-Link)
Information entered in 16-bit units from the remote device station to the master station.
(Expressed as RWr for convenience)
Содержание AJ65VBTCU-68DAVN
Страница 1: ...Digital Analog Converter Module type AJ65VBTCU 68DAVN User s Manual ...
Страница 2: ......
Страница 6: ...A 4 A 4 CONDITIONS OF USE FOR THE PRODUCT ...
Страница 13: ...A 11 A 11 MEMO ...
Страница 18: ...2 2 2 2 MELSEC A 2 SYSTEM CONFIGURATION 2 Remote net ver 2 mode remote net additional mode 2 ...
Страница 41: ...3 19 3 19 MELSEC A 3 SPECIFICATION MEMO ...
Страница 77: ...5 11 5 11 MELSEC A 5 PROGRAMMING 2 Program example ...
Страница 79: ...5 13 5 13 MELSEC A 5 PROGRAMMING ...
Страница 82: ...5 16 5 16 MELSEC A 5 PROGRAMMING ...
Страница 84: ...5 18 5 18 MELSEC A 5 PROGRAMMING Remote registers RWw RWr ...
Страница 92: ...5 26 5 26 MELSEC A 5 PROGRAMMING Remote registers RWw RWr ...
Страница 99: ...5 33 5 33 MELSEC A 5 PROGRAMMING MEMO ...
Страница 111: ......