PARAMETER LIST
13
6
PARAMETER LIST
For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the necessary parameters to meet the load
and operational specifications. Parameter setting, change and check can be performed from the operation panel (FR-DU08).
Pr.
Name
Setting
range
Initial
value
Torque boost
0 to 30%
6/4/3/2/
1%
Maximum frequency
0 to 120Hz
120Hz
60Hz
Minimum frequency
0 to 120Hz
0Hz
Base frequency
0 to 590Hz
60/50Hz
Multi-speed setting
(high speed)
0 to 590Hz
60/50Hz
Multi-speed setting
(middle speed)
0 to 590Hz
30Hz
Multi-speed setting (low
speed)
0 to 590Hz
10Hz
Acceleration time
0 to 3600s
Deceleration time
0 to 3600s
Electronic thermal O/L
relay
0 to 500A
Inverter
rated
current
0 to 3600A
10
DC injection brake
operation frequency
0 to 120Hz,
9999
3Hz
11
DC injection brake
operation time
0 to 10s, 8888
0.5s
12
DC injection brake
operation voltage
0 to 30%
4/2/1%
13
Starting frequency
0 to 60Hz
0.5Hz
14
Load pattern selection 0 to 5, 12 to 15
0
15
Jog frequency
0 to 590Hz
5Hz
16
Jog acceleration/
deceleration time
0 to 3600s
0.5s
17
MRS input selection
0, 2, 4
0
18
High speed maximum
frequency
0 to 590Hz
120Hz
60Hz
19
Base frequency voltage 0 to 1000V,
8888, 9999
9999/
8888
20
Acceleration/
deceleration reference
frequency
1 to 590Hz
60/50Hz
21
Acceleration/
deceleration time
increments
0, 1
0
22
Stall prevention
operation level
(Torque limit level)
0 to 400%
150%
23
Stall prevention
operation level
compensation factor at
double speed
0 to 200%, 9999 9999
24 to
27
Multi-speed setting (4
speed to 7 speed)
0 to 590Hz,
9999
9999
28
Multi-speed input
compensation selection 0, 1
0
29
Acceleration/
deceleration pattern
selection
0 to 6
0
30
Regenerative function
selection
0 to 2, 10, 11,
20, 21,
100 to 102, 110,
111, 120, 121
0
31
Frequency jump 1A
0 to 590Hz,
9999
9999
32
Frequency jump 1B
9999
33
Frequency jump 2A
9999
34
Frequency jump 2B
9999
35
Frequency jump 3A
9999
36
Frequency jump 3B
9999
37
Speed display
0, 1 to 9998
0
41
Up-to-frequency
sensitivity
0 to 100%
10%
42
Output frequency
detection
0 to 590Hz
6Hz
43
Output frequency
detection for reverse
rotation
0 to 590Hz,
9999
9999
44
Second acceleration/
deceleration time
0 to 3600s
5s
45
Second deceleration
time
0 to 3600s,
9999
9999
46
Second torque boost
0 to 30%, 9999 9999
47
Second V/F (base
frequency)
0 to 590Hz,
9999
9999
48
Second stall prevention
operation level
0 to 400%
150%
49
Second stall prevention
operation frequency
0 to 590Hz,
9999
0Hz
50
Second output
frequency detection
0 to 590Hz
30Hz
51
Second electronic
thermal O/L relay
0 to 500A, 9999
9999
0 to 3600A,
9999
52
Operation panel main
monitor selection
0, 5 to 14,
17 to 20,
22 to 36,
38 to 46,
50 to 57, 61, 62,
64, 67,
71 to 75,
87 to 98, 100
0
54
FM/CA terminal
function selection
1 to 3, 5 to 14,
17, 18, 21, 24,
32 to 34, 36, 46,
50, 52, 53, 61,
62, 67, 70,
87 to 90, 92, 93,
95, 97, 98
1
55
Frequency monitoring
reference
0 to 590Hz
60/50Hz
56
Current monitoring
reference
0 to 500A
Inverter
rated
current
0 to 3600A
57
Restart coasting time
0, 0.1 to 30s,
9999
9999
58
Restart cushion time
0 to 60s
1s
59
Remote function
selection
0 to 3, 11 to 13 0
60
Energy saving control
selection
0, 4, 9
0
61
Reference current
0 to 500A, 9999
9999
0 to 3600A,
9999
62
Reference value at
acceleration
0 to 400%, 9999 9999
63
Reference value at
deceleration
0 to 400%, 9999 9999
64
Starting frequency for
elevator mode
0 to 10Hz, 9999 9999
65
Retry selection
0 to 5
0
66
Stall prevention
operation reduction
starting frequency
0 to 590Hz
60/50Hz
67
Number of retries at
fault occurrence
0 to 10,
101 to 110
0
68
Retry waiting time
0.1 to 600s
1s
69
Retry count display
erase
0
0
70
Special regenerative
brake duty
0 to 100%
0%
71
Applied motor
0 to 6, 13 to 16,
20, 23, 24, 30,
33, 34, 40, 43,
44, 50, 53, 54,
70, 73, 74, 330,
333, 334, 8090,
8093, 8094,
9090, 9093,
9094
0
72
PWM frequency
selection
0 to 15
2
0 to 6, 25
73
Analog input selection
0 to 7, 10 to 17 1
74
Input filter time constant 0 to 8
1
75
Reset selection/
disconnected PU
detection/PU stop
selection
0 to 3, 14 to 17,
1000 to 1003,
1014 to 1017
14
0 to 3, 14 to 17,
100 to 103,
114 to 117,
1000 to 1003,
1014 to 1017,
1100 to 1103,
1114 to 1117
76
Fault code output
selection
0 to 2
0
77
Parameter write
selection
0 to 2
0
78
Reverse rotation
prevention selection
0 to 2
0
Operation mode
selection
0 to 4, 6, 7
0
80
Motor capacity
0.4 to 55kW,
9999
9999
0 to 3600kW,
9999
81
Number of motor poles 2, 4, 6, 8, 10,
12, 9999
9999
82
Motor excitation current
0 to 500A,
9999
9999
0 to 3600A,
9999
83
Rated motor voltage
0 to 1000V
200/400V
Pr.
Name
Setting
range
Initial
value
84
Rated motor frequency 10 to 400Hz,
9999
9999
85
Excitation current break
point
0 to 400Hz,
9999
9999
86
Excitation current low-
speed scaling factor
0 to 300%, 9999 9999
89
Speed control gain
(Advanced magnetic
flux vector)
0 to 200%, 9999 9999
90
Motor constant (R1)
0 to 50
Ω
, 9999
9999
0 to 400m
Ω
,
9999
91
Motor constant (R2)
0 to 50
Ω
, 9999
9999
0 to 400m
Ω
,
9999
92
Motor constant (L1)/d-
axis inductance (Ld)
0 to 6000mH,
9999
9999
0 to 400mH,
9999
93
Motor constant (L2)/q-
axis inductance (Lq)
0 to 6000mH,
9999
9999
0 to 400mH,
9999
94
Motor constant (X)
0 to 100%, 9999 9999
95
Online auto tuning
selection
0 to 2
0
96
Auto tuning setting/
status
0, 1, 11, 101
0
100
V/F1 (first frequency)
0 to 590Hz,
9999
9999
101
V/F1 (first frequency
voltage)
0 to 1000V
0V
102
V/F2 (second
frequency)
0 to 590Hz,
9999
9999
103
V/F2 (second frequency
voltage)
0 to 1000V
0V
104
V/F3 (third frequency)
0 to 590Hz,
9999
9999
105
V/F3 (third frequency
voltage)
0 to 1000V
0V
106
V/F4 (fourth frequency) 0 to 590Hz,
9999
9999
107
V/F4 (fourth frequency
voltage)
0 to 1000V
0V
108
V/F5 (fifth frequency)
0 to 590Hz,
9999
9999
109
V/F5 (fifth frequency
voltage)
0 to 1000V
0V
110
Third acceleration/
deceleration time
0 to 3600s,
9999
9999
111
Third deceleration time 0 to 3600s,
9999
9999
112
Third torque boost
0 to 30%, 9999 9999
113
Third V/F (base
frequency)
0 to 590Hz,
9999
9999
114
Third stall prevention
operation level
0 to 400%
150%
115
Third stall prevention
operation frequency
0 to 590Hz
0Hz
116
Third output frequency
detection
0 to 590Hz
60/50Hz
117
PU communication
station number
0 to 31
0
118
PU communication
speed
48, 96, 192, 384,
576, 768, 1152
192
119
PU communication stop
bit length / data length 0, 1, 10, 11
1
120
PU communication
parity check
0 to 2
2
121
PU communication
retry count
0 to 10, 9999
1
122
PU communication
check time interval
0, 0.1 to 999.8s,
9999
9999
123
PU communication
waiting time setting
0 to 150ms,
9999
9999
124
PU communication CR/
LF selection
0 to 2
1
Terminal 2 frequency
setting gain frequency
0 to 590Hz
60/50Hz
Terminal 4 frequency
setting gain frequency
0 to 590Hz
60/50Hz
127
PID control automatic
switchover frequency
0 to 590Hz,
9999
9999
128
PID action selection
0, 10, 11, 20, 21,
40 to 43, 50, 51,
60, 61, 70, 71,
80, 81, 90, 91,
100, 101, 1000,
1001, 1010,
1011, 2000,
2001, 2010, 2011
0
Pr.
Name
Setting
range
Initial
value
Downloaded from