(C) Motor constant parameters
438
For FR-A860-00027, it is set to 85% of the inverter rated current.
For the FR-A860-01080 or lower.
For the FR-A860-01440 or higher.
The setting range and unit change according to the
Pr.71
(
Pr.450
) setting.
POINT
POINT
• The settings are valid under the PM sensorless vector control.
• The offline auto tuning enables the operation with SPM motors and IPM motors. (When a PM motor is used, always perform
the offline auto tuning.)
• Tuning is enabled even when a load is connected to the motor.
• Reading/writing of the motor constants tuned by offline auto tuning are enabled. The offline auto tuning data (motor
constants) can be copied to another inverter with the operation panel.
• The offline auto tuning status can be monitored with the operation panel and the parameter unit.
739
C231
Second motor Ld decay
ratio
9999
0 to 100%, 9999
Tuning data of the second motor.
(The value measured by offline auto
tuning is automatically set.)
9999: The inverter internal data is used.
740
C232
Second motor Lq decay
ratio
9999
0 to 100%, 9999
741
C282
Second starting resistance
tuning compensation
9999
0 to 200%, 9999
742
C285
Second motor magnetic
pole detection pulse width
9999
0 to 6000
μ
s,
10000 to 16000
μ
s, 9999
746
C233
Second motor protection
current level
9999
100 to 500%
Set the maximum current (OCT) level of
the second motor.
9999
Maximum current level of the motor:
200%
Pr.
Name
Initial
value
Setting range
Description