13.9. Parameters of Safety (CR800)
13.9.1. Safety diagnosis function
You can select the pulse output function of test pulse signal output from emergency stop (EXTEMG11,
EXTEMG21).For the safety diagnosis function (test pulse diagnosis), please refer to the “Standard
Specifications” of each series.
This function can be used with the CR800 series robot controller and the parameter cannot be set for offline
editing.
Double-click [Safety Parameter] -> [Safety Diagnosis Function] under the [Parameter].
Figure 13-79 Safety diagnosis function parameter
After changing the parameter value, click the [Write] button to write the parameter to the robot controller.
This parameter requires a password to be written.Enter the correct password and press the [OK], the
parameters will be written to the controller. If the password is wrong, the parameter will not be written.
The password is required only when writing the first parameter after displaying the parameter editing screen of
the safety diagnosis function.
Figure 13-80 Password input screen
The default password is
「
MELFASafetyPSWD
」
.You can click the [Change Password] to change the password
on the [Register / Change Password]. Enter the old and new password on this screen to change the password.
Содержание 3F-14C-WINE
Страница 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Страница 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Страница 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Страница 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Страница 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Страница 624: ...24 624 24 624 Figure 24 4 Document output example ...