![Miteq RL1-095145 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/miteq/rl1-095145/rl1-095145_manual_1807872009.webp)
Introduction | 3
FUNCTIONAL
1:1 Redundant Line Amplifier Performance Specifications
Model Number
Frequency (GHz)
RL1-095145*
RL1-095175*
RL1-095215*
RL1-150180
RL1-200270
RL1-340420
RL1-450480
RL1-572672
RL1-584643
RL1-640720
RL1-725840
RL1-107128
RL1-137148
RL1-177212
RL1-177220
RL1-275310*
RL1-310330*
*References input/output return loss spec.
0.95-1.45
0.95-1.75
0.95-2.15
1.50-1.80
2.00-2.70
3.40-4.20
4.50-4.80
5.725-6.725
5.845-6.430
6.40-7.20
7.25-8.40
10.70-12.75
13.75-14.8
17.70-21.20
17.70-22.00
27.50-31.00
31.00-33.00
Gain
Gain Flatness
Gain Slope
Gain Stability
Power Output (1 dB compression)
Channel-to-Channel Gain Match
Noise Figure
Below 4.2 GHz
4.2 GHz to 12.75 GHz
12.75 GHz to 14.5 GHz
Above 14.5 GHz
Spurious Outputs
AM/PM Conversion
Isolation
Input Return Loss
Input/Output Impedance
30 dB minimum
40 dB minimum (Option 16A)
50 dB minimum (Option 16B)
0.4 dB/any 40 MHz
1.0 dB peak-to-peak/up to 500 MHz
1.5 dB peak-to-peak/up to 800 MHz
2.0 dB peak-to-peak/greater than 800 MHz
0.2 dB/10 MHz maximum
±0.2 dB/24 hours (constant temperature)
+10 dBm minimum
+15 dBm minimum (Option 11A)
+20 dBm minimum (Option 11B)
2 dB maximum
3 dB maximum
4 dB maximum
5 dB maximum
8 dB maximum
Below Thermal Noise
0º5 /dB maximum to 0 dBm output
50 dB minimum
20 dB minimum
*10 dB minimum (refer to table)
50 ohms
Primary Power Requirements
Voltage
Power Consumption
Frequency
90-250VAC
40 Watts nominal
47-63 Hz
Environmental (Operating)
Ambient temperature
Relative humidity
Atmospheric pressure
Environmental (Non-operating)
Ambient temperature
Relative humidity
Atmospheric pressure
Shock and vibration
0 to +50°C
Up to 95% at 30°C
Up to 10,000 feet
-50 to +70°C
Up to 95% at 40°C
Up to 40,000 feet
Normal handling by commercial carriers