Operation | 26
AMPLIFIER PRIORITY = PRI
The SET command requires one parameter a single digit in length representing the amplifier path which will have the
higher priority.
Command
Parameters
Remote Command Sequence: $PRIa
Unit Response:
$PRI
a = 1 = A1
a = 2 = A2
The QUERY command requires no parameters.
Command
Parameters
Remote Command Sequence: ?PRI
Unit Response:
?PRIa
a = 1 = A1
a = 2 = A2
This command is only applicable to 1:2 Redundancy units. If used with a 1:1 or Dual 1:1 unit the response
will be “a” (command not recognized).
SLOPE = SLP
The Slope command is only valid for units with the slope equalization option. The SET command requires three
parameters. The first parameter is a single ASCII digit representing the path number. The second parameter is a single
ASCII character representing the sign of the slope. The third parameter is two ASCII characters in length representing the
magnitude of the slope in tenths of a dB.
Command
Parameters
Remote Command Sequence: $SLPnsbb
Unit Response:
$SLP
The QUERY command requires one parameter. The parameter is a single ASCII digit representing the path number.
Command
Parameters
Remote Command Sequence: ?SLPn
Unit Response:
?SLPnsbb
n = path number
s = sign of slope + or -
bb = slope setting in tenths of a dB
For a 1:1 system
n = 1 = Module 1 in Primary Path
n = 2 = Module 1 in Standby Path
n = 3 = Module 2 in Primary Path
n = 4 = Module 2 in Standby Path
For a 1:2 system
n = 1 = Module 1 in Primary Path1
n = 2 = Module 1 in Standby Path
n = 3 = Module 2 in Primary Path2
n = 4 = Module 2 in Standby Path
n = 5 = Module 3 in Primary Path 1
n = 6 = Module 3 in Primary Path 2
Note