![Miteq RL1-095145 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/miteq/rl1-095145/rl1-095145_manual_1807872022.webp)
Operation | 16
Change Attenuation:
1P represents attenuation applied to Amp.1 when in the Primary Path. 1S represents attenuation applied to Amp.1
when in the Standby Path.
2P represents attenuation applied to Amp.2 when in the Primary Path. 2S represents attenuation applied to Amp.2
when in the Standby Path.
Point the arrow cursor to the desired attenuator. The UP, DOWN, LEFT and RIGHT keys move the arrow cursor. If the
desired attenuator is not on the display, the other attenuator(s) may be reached by using the DOWN key (1:2 and Dual
1:1 units only).
Use the RIGHT key to select that attenuator.
UP and DOWN keys change the digit presently under the blinking cursor.
RIGHT and LEFT keys move the cursor horizontally. If the cursor is moved all the way to the left (the cursor will turn
into an arrow), any pending changes will be erased.
ENTER or MENU keys both operate as an escape key.
Changes to the attenuation do not require the ENTER key to be pressed to confirm.
Set Slope Screen
If not already displayed, use the MENU and arrow keys to select the SET SLOPE screen, then press ENTER.
Figure 3-18. Set Slope Screen*
*Exact screen format varies by model type.
Change Slope:
1P represents slope adjustment applied to Amp.1 when in the Primary Path. 1S represents slope adjustment applied
to Amp.1 when in the Standby Path.
2P represents slope adjustment applied to Amp.2 when in the Primary Path. 2S represents slope adjustment applied
to Amp.2 when in the Standby Path.
Point the arrow cursor to the desired slope. The UP, DOWN, LEFT and RIGHT keys move the arrow cursor. If the
desired slope is not on the display, the other slope(s) may be reached by using the DOWN key (1:2 and Dual 1:1 units
only).
Use the RIGHT key to select that slope.
UP and DOWN keys change the digit presently under the blinking cursor.
RIGHT and LEFT keys move the cursor horizontally. If the cursor is moved all the way to the left (the cursor will turn
into an arrow), any pending changes will be erased.
ENTER or MENU keys both operate as an escape key.
Changes to the slope do not require the ENTER key to be pressed to confirm.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
→1P: 10.0 1S: 10.0
2P: 10.0 2S: 10.0