Access Control Sequences
8380-383-115-BA
Issue 1, February 1999
54
9. 9. Programmable Tone Detector
The tone detector provides center frequency selection with an approximate 7 percent window
of frequency detection granularity around the center frequency. The
✳
4XY token must be used
before the #
✳
AB token in order to initiate the programmable detector.
✳
4XY
Selects the frequency for the programmable detector.
#
✳
AB
Selects the programmable tone detector (for A and B values, refer to page
52).
9. 9. 1. Example
•
625
✳
410#
✳
5127
*4
set programmable tone detector frequency
10
look for 1000 Hz frequency
#*
enable the programmable tone detector
51
where 5 is the A value (wait for a minimum amount of dial tone) and 1 is the B
value (two seconds)
2
dial destination number
7
through connect
9. 10. 6R1 - Access Number for Carrier Telephone Network
When programmed, this access number will be output on calls routed as a Carrier connection
that requires an access number to be dialled out before allowing access. This Register is dialled
out by using the “3” ACS token. The Default value for all Routes is blank. This entry can be a
maximum of 80 digits.
Note: This register should end with a ##, which indicates that the string is finished.
XY
Frequency Selected
00 - 09
10 - 23
24 - 99
Defaults to 100 Hz
1000 Hz - 2300 Hz (100 Hz intervals)
240 Hz - 990 Hz (10 Hz intervals)
Register
Description
6R1
Where R is the Route Number 1 through 8. This entry may contain up to 80 characters
maximum, and is Blank by default.
Example: 611 1234567890##
Содержание SmarT-1 50000241
Страница 8: ...Table of Contents 8380 383 115 BA 7 Issue 1 February 1999 ...
Страница 12: ...Safety Information 8380 383 115 BA 11 Issue 1 February 1999 ...
Страница 18: ...SMarT 1 EuroRoute One line Dialer Installation 8380 383 115 BA 17 Issue 1 February 1999 ...
Страница 20: ...System Requirements 8380 383 115 BA 19 Issue 1 February 1999 ...
Страница 24: ...Initialisation 8380 383 115 BA 23 Issue 1 February 1999 ...
Страница 28: ...Security Access Registers 8380 383 115 BA 27 Issue 1 February 1999 ...
Страница 50: ...Line and Trunk Options 8380 383 115 BA 49 Issue 1 February 1999 ...
Страница 58: ...Access Control Sequences 8380 383 115 BA 57 Issue 1 February 1999 ...
Страница 68: ...Search Tables 8380 383 115 BA 67 Issue 1 February 1999 ...
Страница 72: ...Common Option Data 8380 383 115 BA 71 Issue 1 February 1999 ...
Страница 78: ...Cost Centre Code Options 8380 383 115 BA 77 Issue 1 February 1999 ...
Страница 86: ...Appendix 2 Default Data 8380 383 115 BA 85 Issue 1 February 1999 ...
Страница 90: ...Appendix 4 Hardware Specifications 8380 383 115 BA 89 Issue 1 February 1999 ...