Alarm Queue
Alarm Queue
Software versions 8.2 and later support the Alarm Queue feature. This feature prioritizes sys-
tem and network alarms based on severity and allows System Administrators to view and han-
dle critical alarms before addressing minor alarms. You can then clear the individual alarm, or
clear all the alarms in the queue (up to 30). When clearing alarms individually, the alarms are
displayed in order of severity. The Emergency Alarm (when an extension has dialed emer-
gency services) is the only priority 1 alarm. Other prioritized alarms have a 2, 3, or 4 priority,
based on the severity of the alarm.
Not all alarms have a number 1,2, 3, or 4 priority. The numbered priority scheme is limited to
alarms that can cause a major or minor system reset. Those alarms in the Alarm Queue that
have a numbered priority (1-4) are displayed before the alarms that do not receive a numbered
priority. Alarms that do not have a numbered priority are prioritized in the queue by date and
time.
When alarms are generated:
•
The highest priority alarm is placed in the front of the queue, regardless of when lower
priority alarms are generated. For example, if A114 (priority 3) and A116 (priority 4)
are currently in the queue, but A119 (priority 2) is generated, A119 is placed first in the
queue.
•
Alarms with the same priority level are placed in the queue based on the time the alarm
was generated. For example, if A010 (priority 3) is generated at 10:30 AM, and A012
(priority 3) is generated at 10:32 AM, A012 is placed in the queue after A010.
•
If the queue contains 30 alarms, the oldest, lowest priority alarm is overwritten with the
new alarm. For example, if the queue currently holds 30 alarms, 20 of which are prior-
ity 4, and a priority 3 alarm is generated, the oldest priority 4 alarm is overwritten.
•
Repetitive alarms such as A125, are placed in the queue only once. If the alarm is
regenerated, the alarm that is currently in the queue is overwritten with the new alarm
data (if applicable) and time. For example, A125 is overwritten each time it is regener-
ated, which is every five minutes. This prevents the queue from being filled with dupli-
cate alarms.
Содержание Inter-Tel Axxess
Страница 1: ...Inter Tel Axxess Converged Communications Platform M I T E L Administrator Guide ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 14: ......
Страница 26: ......
Страница 88: ......
Страница 304: ......
Страница 368: ......
Страница 384: ...Part No 550 8001 Issue 11 0 May 2008 A661 9112A ...