SELF-POWERED IR BARRIER 

Compatible with any radio transmitter 

 

Installation and user manual 

INSTALLATION  

1. 
2. 
 
 
3. 
 
 
 
 

Remove the caps and the extruded cover. 
Drill the aluminium profiles at both ends and fix them to the wall 
paying attention to keep them on the same axis (Fig.1), for longer 
barriers drill additional holes as required. 
Connect the battery and press briefly the reset button on the RX 
motherboard, paying attention not to block the 
transmission beams; the buzzer will signal the individual double 
beams have been received (Fig. 2). 

After this, a single long beep will confirm programming in AND 
mode, and a double beep programming in OR mode (see 
section SETTING JUMPER) 

TECHNICAL FEATURES AND CONSUMPTION: 

Maximum and minimum range: max. 5 m – min. 20 cm 
Operating temperature: -25°C + 70°C 
Synchronization: optical 
Detection system: OR-AND 
Battery model: Lithium 3.6V/5200 mAh (Spare part: TREN BAT), endurance: 24 months 
Maximum consumption: 190μA TX + 200μA RX 
Protection class: IP54 

MADE IN ITALY 

TRENDY - Rev. 12 - 03/2019 - MITECH srl reserves the right to change the information in this document without warning 

Page 1 of 2 

TRENDY is a wireless, self-powered IR barrier with double led and 24 month endurance, which is compatible with any radio transmitter. 
It is composed of two symmetrical bars to be installed on either sides of the entrances to be protected and it allows to anticipate 
intrusion by leaving freedom to move indoors with even windows and doors open. 

BUZZER SIGNALS 

1. 
2. 
3. 
 
4. 
 

N.C. or N.O. alarm warnings. 
Reception warning of the beam signal. 
Low battery warning every 30 minutes, active on both barriers . 
O.C. output to negative BATT 0 
Tamper warning, N.C. output. 

Note: the buzzer can be silenced by turning JUMPER BUZ to OFF 

Fig. 1 

Fig. 2 

SETTING JUMPER 

TX BASE BOARD 

RANGE JUMPER: 

when the range between RX and TX is less than 50cm, insert the Jumper into 

position “L” only if there are alignment problems. 

BUZZER JUMPER: 

OFF mode =  the buzzer is deactivated, ON mode = the buzzer is activated 

RX BASE BOARD 

PROGRAMMING JUMPER: 

-

OR mode = the alarm is activated when just one optical group is covered 

-

AND mode = the alarm is activated when two random optical groups are covered 

BUZZER JUMPER: 

OFF mode = the buzzer is deactivated, ON mode = the buzzer is activated 

TX AND RX EXPANSION BOARDS 

The jumpers on each TX and RX modules are set as standard and must not be removed. 

OPTICAL 

SYNCHRONIZATION 