background image

FOSTER POWER 

Installation and user manual  

Page 19 of 20 

Содержание FOSTER POWER

Страница 1: ...FOSTER POWER ACTIVE INFRARED BARRIER WITH INTEGRATED POWER SUPPLY Installation and user manual MADE IN ITALY ...

Страница 2: ...tions Page 5 Examples of installation Page 6 Pole mounting with bracket FTN SUP 5 Wall mounting with bracket FTN WL 5 Receiver and transmitter motherboards Page 8 Power supply Page 10 Alignment Page 11 Settings and programming Page 13 Description of signalling leds 14 Description of jumper settings 15 Technical features and consumption Page 16 Notes Page 17 Receiver RX 8 Transmitter TX 9 ...

Страница 3: ...columns FOSTER POWER standard equipped with automatic temperature control device disqualification system and sturdy aluminium structure is synonymous with security and reliability WARNINGS Use shielded cables Observe the minimum distances between the TX and RX columns see table on page 16 In areas subject to intense fog for distances longer than 80 m it is advisable to break the barrier path with ...

Страница 4: ...ium support bar 2 1 IR cover 3 2 2 Plugging caps Rubber screw cap 4 from 2 to 5 Optical groups receiver transmitter 5 from 2 to 5 Flat cable 6 1 Motherboard 7 from 2 to 5 Expansion board 8 1 Tamper board Accessories Part No Code Description 1 FTN SUP Pole mounting bracket 1kit comprises two pieces A B 2 FTN WL Wall mounting bracket ...

Страница 5: ...ps of the transmitters and receivers e g branches plants leaves etc that could interfere with the beams Verify that the optics of the transmitter and receiver units are not exposed to direct sunlight at dawn and sunset It is usually advisable to reverse the transmitters and receivers when installing the barriers overlapped as this could cause the transmitters to interfere with several receivers se...

Страница 6: ...allation and user manual Page 6 of 20 POLE FIXING 1 POLE FIXING 2 WALL FIXING COMBINED WITH TOWER GARDEN IR COLUMNS Overlapped solution AREA TO PROTECT AREA TO PROTECT AREA TO PROTECT AREA TO PROTECT Single lens barriers Double lens barriers ...

Страница 7: ...barriers come with crossed beams for maximum protection For visibility purposes the beams in this drawing are linear RX TX BARRIERS IR BEAMS TRANSMITTION RX TX RX TX RX TX BARRIERS WARNING Ensure no interference is caused by the presence of photocells for automatic gates or infrared cameras as these may blind the barriers ...

Страница 8: ...R BEAMS SELECTOR Barrier with 2 lenses no jumper Barrier with 3 lenses jumper 3 inserted Barrier with 4 lenses jumper 3 and 4 inserted Barrier with 5 lenses jumper 3 4 and 5 inserted HEATING POWER SUPPLY 24 Vac LED1 S LOW LOW SIGNAL LED2 MASK MASKING LED3 DETECT DETECTION LED4 ALM ALARM LED5 HTR HEATING LED6 POWER POWER SUPPLY AUTOMATIC FOG DISABLING ON ACTIVE OFF NOT ACTIVE ON OFF LEDS AND FUNCTI...

Страница 9: ...OR THERMAL SENSOR BEAMS SELECTOR Barrier with 2 lenses only jumper 2 inserted Barrier with 3 lenses only jumper 3 inserted Barrier with 4 lenses only jumper 4 inserted Barrier with 5 lenses only jumper 5 inserted HEATING POWER SUPPLY 24 Vac LED2 TEST MODE LED3 HTR HEATING LED4 POWER SUPPLY ON OFF LEDS POWER SUPPLY 12 V 0 V GND TAMPER OUTPUT LED1 CLOCK FLASHING LED 2 3 4 5 6 7 8 9 10 BEAM ON OFF AL...

Страница 10: ...ION 13 8 0 8A MAX SUPPLIED CURRENT 1 A protection fuse of 24 Vac output 2A sr LED when on indicates that the output is working correctly F1 protection fuse against battery polarity reversal and overload F2 protection fuse 24 Vac output FAULT OUTPUT indicates the absence of power supply from the mains normally high WEIGHT AND DIMENSIONS weight 0 500 Kg dimensions H45 x L130 x P45 mm 220 Vac 220 Vac...

Страница 11: ... the transmitters until all the leds are turned off If one or more leds are not turned off go directly to the instrumental alignment procedure described on page 16 NORMAL NOISE TEST LED ALM T P MI TECH RX FEBRX Image 1 WARNINGS Before the instrumental alignment verify the following on the receiver motherboard the blinding led must be switched off the AND and S LOW jumpers must be set to OFF the MA...

Страница 12: ...the TEST jumper on the first TX expansion board to ON MULTIMETER Measurement in Vcc Reference value approx 4V Cable supplied red black Led TX Jumper insertion Flat cable NOTES a some multimeters might display a voltage that is up to 50 lower than the real value therefore check the tester is working correctly b the use of some transceivers to communicate during installation could affect the multime...

Страница 13: ...t the bottom and repeat from step 3 the alignment of all the remaining TX expansion boards MULTIMETER Cable supplied red black Measurement in Vcc Reference value approx 4V 6 Ensure all the TEST jumpers of the TX motherboard and of the TX expansion boards are set to OFF FINAL TEST Double lens version verify that the barrier triggers an alarm signal when both lenses of each optical group are covered...

Страница 14: ...n electromagnetic interference or a wiring problem that may affect the correct functioning of the barrier Led DETECT Irregular transmission signal This led is generally OFF in ordinary operating conditions The led blinks if one or more transmitter signals are not detected by the receivers It lights permanently if all the transmitters signals are not detected by the receivers Verify alignment and p...

Страница 15: ...bles the signal LEDS Trimmer SPEED For adjusting the tripping time from 50 ms to 500 ms the delay increases by turning the trimmer clockwise Trimmer MASK For adjusting the sensitivity of the blinding function the sensitivy increases by turning the trimmer clockwise RX motherboard Jumper BEAM Number of beams selector see diagram on page 13 Jumper TEST To use for alignment see page 16 Jumper LEDS In...

Страница 16: ...ber of beams 50 crossed Power supply 220 V Disqualification Automatic with external signals Maximum column consumption 4 lenses version Tx 120 mA Rx 230 mA Maximum heaters absorption 60 W Operating temperature 25 C 70 C Alignment angle Vertical 30 horizontal 180 Detection system AND OR on Tx and Rx remote AND Anti masking Automatic can be disabled Tripping time Adjustable 50 500 ms Alarm and tampe...

Страница 17: ...FOSTER POWER Installation and user manual Page 17 of 20 Notes ...

Страница 18: ...FOSTER POWER Installation and user manual Page 18 of 20 ...

Страница 19: ...FOSTER POWER Installation and user manual Page 19 of 20 ...

Страница 20: ...ion Via Ramazzone 23 43010 Fontevivo PR Italy Phone 39 02 48006383 Fax 39 02 48025620 tech mitech security com www mitech security com MADE IN ITALY FOSTER POWER Rev 3 03 2019 MITECH srl reserves the right to change the information in this document without warning ...

Отзывы: