FOSTER POWER
Installation and user manual
Page 10 of 20
Power supply
WARNINGS
Always use filtered and stabilized 230 Vac voltage.
Then check the cabling before connecting the power supply
TECHNICAL SPECIFICATIONS
POWER SUPPLY
220 Vac +/- 10%
OUTPUTS
OUTPUT 1
: 12,5 ÷14,3 Vdc (clamps: 5 and 6) -
OUTPUT 2
: 24 Vac (clamps: 1 and 2)
CALIBRATION
13,8 @ 0,8A
MAX. SUPPLIED CURRENT
1 A protection fuse of 24 Vac output (2A sr)
LED
when on, indicates that the output is working correctly
F1
protection fuse against battery polarity reversal and overload
F2
protection fuse 24 Vac output
FAULT OUTPUT
indicates the absence of power supply from the mains (normally high)
WEIGHT AND DIMENSIONS
weight: 0,500 Kg - dimensions: H45 x L130 x P45 mm
220 Vac
220 Vac
F2
F1
OUTPUT VOLTAGE ADJUSTMENT
LED
FAULT OUTPUT
1: +12 Vdc
2: -12 Vdc
3:
4: 24 Vac
5: 24 Vac
BATTERY
CONNECTOR
BATTERY
CONNECTOR
+
-