background image

 

http://www.tyan.com

 

1

 

 

 

S5542 

 Version 1.0d

 

 
Copyright 

Copyright © 2017 MITAC COMPUTING TECHNOLOGY CORPORATION. All rights 
reserved. No part of this manual may be reproduced or translated without prior 
written consent from MITAC COMPUTING TECHNOLOGY CORPORATION. 

 

Trademark 

All registered and unregistered trademarks and company names contained in this 
manual are property of their respective owners including, but not limited to the 
following. 

 

TYAN

®

 is a trademark of MITAC COMPUTING TECHNOLOGY CORPORATION. 

Intel

®

 is a trademark of Intel

®

 Corporation. 

AMI, AMI BIOS are trademarks of AMI Technologies. 
Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Nuvoton

®

 is a trademark of Nuvoton Technology Corporation. 

 
Notice 

Information contained in this document is furnished by MITAC COMPUTING 
TECHNOLOGY CORPORATION and has been reviewed for accuracy and reliability 
prior to printing. MiTAC assumes no liability whatsoever, and disclaims any express 
or implied warranty, relating to sale and/or use of TYAN

®

 products including liability 

or warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications at 
any time, without notice. In no event will MiTAC be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 
 
 

Содержание Tyan S5542

Страница 1: ...ks of Microsoft Corporation Nuvoton is a trademark of Nuvoton Technology Corporation Notice Information contained in this document is furnished by MITAC COMPUTING TECHNOLOGY CORPORATION and has been reviewed for accuracy and reliability prior to printing MiTAC assumes no liability whatsoever and disclaims any express or implied warranty relating to sale and or use of TYAN products including liabil...

Страница 2: ...http www tyan com 2 ...

Страница 3: ...ermal Interface Material 37 2 8 Tips on Installing Motherboard in Chassis 38 2 9 Installing the Memory 40 2 10 Attaching Drive Cables 43 2 11 Installing Add In Cards 44 2 12 Connecting External Devices 45 2 13 Installing the Power Supply 46 2 14 Finishing Up 46 Chapter 3 BIOS Setup 47 3 1 About the BIOS 47 3 2 Main Menu 49 3 3 Advanced Menu 50 3 4 Chipset Menu 76 3 5 Security 83 3 6 Server Managem...

Страница 4: ...ntain the following 1 x S5542 Motherboard 2 x SATA Cable 1 x Rear IO Shield 1 x S5542 Quick reference guide 1 x TYAN Driver s and Utilities DVD IMPORTANT NOTE Sales sample may not come with the accessory listed above Please contact your sales representative to help order accessory for your evaluation ...

Страница 5: ... provides the S5542 with the power and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan com There you can find all the information on all TYAN products as well as all the supporting documentation FAQs Drivers and BIOS upgrades 1 2 Hardware Specifications TYAN S5542 S5542G2NR UHE Processor Socket Type Q ty LGA1151 1 Supported...

Страница 6: ...Others 1 Reset button 1 Power button System Monitoring Chipset Aspeed AST1400 Fan Total 4 4 pin headers Temperature Monitors temperature for CPU system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support BIOS Brand ROM size AMI 16MB Feature Hardware Monitor ACPI 5 0 SMBIOS 3 0 PnP W...

Страница 7: ...lation CD TYAN S5542 S5542G2NR UHE M2 Processor Socket Type Q ty LGA1151 1 Supported CPU Series Intel Xeon processor E3 1200 v6 v5 product family Thermal Design Power TDP wattage Max up to 80W Chipset PCH Intel C236 Memory Supported DIMM Qty 4 DIMM slots DIMM Type Speed Unbuffered ECC UDIMM DDR4 2133 2400 Capacity Up to 64GB Memory channel 2 Channels Memory voltage 1 2V Expansion Slots PCI E 1 PCI...

Страница 8: ...ring Chipset Aspeed AST1400 Fan Total 4 4 pin headers Temperature Monitors temperature for CPU system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support BIOS Brand ROM size AMI 16MB Feature Hardware Monitor ACPI 5 0 SMBIOS 3 0 PnP Wake on LAN ACPI sleeping states S3 S4 S5 Boot from...

Страница 9: ... 1 Supported CPU Series Intel Xeon processor E3 1200 v6 v5 product family Thermal Design Power TDP wattage Max up to 80W Chipset PCH Intel C232 Memory Supported DIMM Qty 4 DIMM slots DIMM Type Speed Unbuffered ECC UDIMM DDR4 2133 2400 Capacity Up to 64GB Memory channel 2 Channels Memory voltage 1 2V Expansion Slots PCI E 1 PCI E Gen 3 x16 slot w x8 link 1 PCI E Gen 3 x8 slot 2 PCI E Gen 3 x1 slot ...

Страница 10: ...CPU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2400 AST2400 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2400 i...

Страница 11: ...nual 1 Web User s manual 1 Quick Installation Guide Installation CD 1 TYAN installation CD TYAN S5542 S5542GM4NR Processor Socket Type Q ty LGA1151 1 Supported CPU Series Intel Xeon processor E3 1200 v6 v5 product family Thermal Design Power TDP wattage Max up to 80W Chipset PCH Intel C232 Memory Supported DIMM Qty 4 DIMM slots DIMM Type Speed Unbuffered ECC UDIMM DDR4 2133 2400 Capacity Up to 64G...

Страница 12: ...1x5 pin header Others 1 Reset button 1 Power button System Monitoring Chipset Aspeed AST2400 Fan Total 4 4 pin headers Temperature Monitors temperature for CPU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2400 ...

Страница 13: ...idity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Operating System OS supported list Please refer to our Intel OS supported list Package Contains Motherboard 1 S5542 Motherboard Manual 1 Web User s manual 1 Quick Installation Guide Installation CD 1 TYAN installation CD TYAN S5542 S5542WGM2NR Processor Socket Type Q ty LGA1151 1 Supported CPU Series Intel Xeon processor E3 1200 v6 v5 pro...

Страница 14: ...0 Gb s RAID RAID 0 1 10 5 Intel RST Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2400 Input Output USB 3 USB2 0 ports 2 via cable 1 Type A 6 USB3 0 ports 4 at rear 2 via cable COM 2 ports 1 at rear 1 via cable VGA 1 D Sub 15 pin VGA port RJ 45 2 GbE ports 1 Dedicated for IPMI SAS 2 Mini SAS HD 4 in 1 connectors SATA 6 SATA III connectors PSMI 1 1x5 pin header Ot...

Страница 15: ...3 0 PnP Wake on LAN ACPI sleeping states S3 S4 S5 Boot from USB device PXE via LAN Storage User Configurable FAN PWM Duty Cycle Console Redirection Physical Dimension Form Factor ATX Board Dimension 12 x9 6 305x243 8mm Regulation FCC DoC Class A CE DoC Yes Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at...

Страница 16: ...I E Gen 3 x1 slot LAN Port Q ty 4 ports 1 dedicated for IPMI Controller Intel I210 AT PHY Broadcom BCM5221 PHY dedicated for IPMI connection Storage SAS Connector 2 Mini SAS HD connectors totally support 8 ports Controller LSI SAS3008 Speed 12 0 Gb s RAID RAID 0 1 1E 10 LSI Integrated RAID SATA Connector 6 SATA Controller Intel C232 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RST Graphic Connector typ...

Страница 17: ...d Aspeed AST2400 AST2400 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2400 iKVM Feature 24 bit high quality video compression 10 100 Mb s MAC interface BIOS Brand ROM size AMI 16MB Feature Hardware Monitor ACPI 5 0 SMBIOS 3 0 PnP Wake on LAN ACPI sleeping states S3 S4 S5 Boot from USB device PXE via LA...

Страница 18: ...omparison Table Part Number BMC PCH Expand slot SAS 12 Gb s SAS Raid SATA 6 Gb s 1G LAN USB 3 0 M 2 NGFF X16 X8 X4 x1 S5542GM2NR Yes C232 1 1 0 2 0 No 6 2 4 0 S5542WGM2NR Yes C232 1 0 0 2 8 Yes 6 2 4 0 S5542GM4NR Yes C232 1 1 0 2 0 No 6 4 4 0 S5542WGM4NR Yes C232 1 0 0 2 8 Yes 6 4 4 0 S5542G2NR UHE No C236 1 2 0 2 0 No 8 2 4 0 S5542G2NR UHE M2 No C236 1 2 0 2 0 No 7 2 4 1 1 3 Software Specificatio...

Страница 19: ...touch a safely grounded object to release static charge i e power supply case For the safest conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboard components IC chips connectors memory modules and leads 4 Place the motherboard on a grounded antistatic...

Страница 20: ...ttp www tyan com 20 2 1 Board Image S5542 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture ...

Страница 21: ...http www tyan com 21 2 2 Block Diagram S5542 Block Diagram ...

Страница 22: ...http www tyan com 22 2 3 Mainboard Mechanical Drawing ...

Страница 23: ... of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memory installation For the latest board revision please visit our web site at http www tyan com ...

Страница 24: ...25 DIMM_A0 DDR4 Blue Address 0xA0 J8C1 11 PCI Express Slot x1 Slot w x1 link J17 26 DIMM_A1 DDR4 Black Address 0xA2 J8C2 12 SAS Port LSI SAS3008 MINI SAS 2 Port 12 Gbit s J28 27 DIMM_B0 DDR4 Blue Address 0xA4 J8C3 13 SAS Port LSI SAS3008 MINI SAS 2 Port 12 Gbit s J29 28 DIMM_B1 DDR4 Black Address 0xA6 J8C4 14 USB Port USB2 0 Type A 480M s J33 29 ATX 24 Pin Power Supply Connector J32 PW1 15 SATA Po...

Страница 25: ...ear Jumper J26 ii BMC Heart Beat LED Green LED2 c ME Firmware Update Jumper J256 iii LSI SAS3008 Action LED Green LED1 iv LSI SAS3008 Error LED Red LED4 v M 2 Action LED Green SSD_LED1 vi BMC Caterr Error LED Red LED5 Jumper Legend OPEN Jumper OFF Without jumper cover CLOSED Jumper ON With jumper cover ...

Страница 26: ...keep the system stable and reliable J20 Front Panel Header Signal Pin Pin Signal PWRLED 1 2 VCC3_AUX KEY 3 4 IDLED PWRLED 5 6 IDLED HDDLED 7 8 SYS_FAULT1 HDDLED 9 10 SYS_FAULT2 PWR_SW 11 12 LAN1LED GND 13 14 LAN1LED RESET_SW 15 16 SMBDATA GND 17 18 SMBCLK IDLED_SW 19 20 INTRUSION TEMP SENSOR 21 22 LAN2LED NMI_SW 23 24 LAN2LED J16 PSMI Connector Signal Pin Pin Signal SMB_CLK 1 2 SMB_DAT SMB_ALERT 3...

Страница 27: ...0 CLK INTRD1 Chassis Intrusion Pin Header Signal Pin Pin Signal INTRUSION 1 2 GND FP_USB_1 Front USB2 0 Header blue Signal Pin Pin Signal VCC 1 2 VCC USBD 3 4 USBD USBD 5 6 USBD GND 7 8 GND KEY 9 10 NC SATA0 J46 SATA1 J45 SATA2 J44 SATA3 J43 SATA4 J42 SATA5 J41 SATA6 J40 SATA7 J39 SATA III 6G Connector PIN Define Pin Connects to the Serial ATA ready drives via the Serial ATA cable 1 GND 2 SATA TX ...

Страница 28: ...B_PCH DP2_R USB_PCH_DP4_R 11 10 USB_PCH_OC24_N_ID J13 TYAN Module Header Signal Pin Pin Signal VCC3 1 2 FRAME LAD0 3 4 KEY LAD1 5 6 RESET LAD2 7 8 GND LAD3 9 10 CLK LSIRQ0 11 12 GND TPM_PRSNT 13 14 VCC3_AUX NC 15 16 NC J33 Vertical Type A USB2 0onnector Pin Signal 1 USB 5V Power 2 USB Data 3 USB Data 4 GND J37 Power Switch Button Signal Pin Pin Signal FP_PWR_BTN_N 1 2 FP_PWR_BTN_N GND 3 4 GND J36 ...

Страница 29: ...em setup password or need to clear the system BIOS setting 1 Power off system and disconnect power connectors from the motherboard 2 Remove the jumper from Pin_2 and Pin_3 Default setting 3 Move the jumper cap to close Pin_1 and Pin_2 for several seconds to Clear CMOS 4 Put jumper cap back to Pin_2 and Pin_3 Default setting 5 Reconnect power connectors to the motherboard and power on system Clear ...

Страница 30: ...http www tyan com 30 2 5 LED Definitions ...

Страница 31: ...Signal 3V_AUX GND State Description OFF OFF The LED shuts off when the BMC controller cannot be detected or properly initiated ON Green The LED blinks per second to indicate that the BMC controller is working normally LED3 Rear ID LED Pin Signal VCC3_AUX GND State Description OFF OFF OFF ON Green ON LED4 LSI SAS3008 Error LED Pin Signal VCC3 GND State Description OFF OFF The LED shuts off when Sys...

Страница 32: ...ed The LED lighted up when the system has experienced a fatal or catastrophic error and can not continue to operate SSD_LED1 M 2 Action LED Green Pin Signal VCC3 GND State Description OFF OFF The LED shuts off when no M 2 devices or M 2 devices no active ON Green The LED blinks per second to indicate that M 2 devices is active and working normally ...

Страница 33: ...r Installation SNB_H4 LGA1151 for Intel Skylake CPU Follow the steps below to install the processors and heat sinks Please note that the illustrations are based on a SNB_H4 LGA1151 which may not look exactly like the motherboard you purchased Therefore the illustrations should be held for your reference only NOTE Please save and replace the CPU protection cap when returning for service 1 Locate th...

Страница 34: ...e the CPU protection cap 5 Install the processor and make sure the gold arrow is located in the right direction with two notches properly aligned 6 Close the CPU socket cover 7 Press the socket lever down to lock the CPU in place ...

Страница 35: ...he overheated processor is dangerous to the motherboard For the safest method of installation and information on choosing the appropriate heat sink using heat sinks validated by Intel Please refer to the Intel website http www intel com The following diagram illustrates how to install the heat sink for the SNB_H3 LGA1150 socket 1 Apply the thermal grease 2 Place the heat sink on top of the CPU and...

Страница 36: ...http www tyan com 36 3 Secure the heat sink screws 4 Connect the fan cable to complete the installation ...

Страница 37: ...o touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as thermal compound Simply apply a thin layer on to the CPU lid applying too much will actually reduce the cooling NOTE Always check with the manufacturer of the heat sink processor to ensure that the therm...

Страница 38: ...mply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will not be able to be securely installed Some chassis include plastic studs instead of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the moth...

Страница 39: ...http www tyan com 39 ...

Страница 40: ... TYAN Web site at http www tyan com for details of the type of memory recommended for your motherboard Supports up to 64GB of un buffered non ECC UDIMM DDR4 2133 2400MHz memory Supports single dual rank memory All installed memory will automatically be detected and no jumpers or settings need changing All memory must be of the same type and density DIMM Location ...

Страница 41: ... 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 Dual rank DIMMs are recommended over single rank DIMMs 5 Un buffered DIMM can offer slightly better performance than registered DIMM if populating only a single DIMM per channel 6 Always install with DIMM_A0 Slot first ...

Страница 42: ...nstructions to install memory modules into the S5542 1 Unlock the clips as shown in the illustration 2 Insert the memory module firmly into the socket by gently pressing down until it sits flush with the socket 3 Lock the clips to secure the memory module into place ...

Страница 43: ...es are very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase The following pictures illustrate how to connect an SATA drive 1 SATA drive cable connection 2 SATA drive power connection 3 SATA cable motherboard connector 4 SATA drive power adapter ...

Страница 44: ...not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TIP It s a good practice to install add in cards in a staggered manner rather than making them directly adjacent to each other Doing so allows air to circulate within the chassis more easily thus improving co...

Страница 45: ...t software may be required to complete the installation Onboard LAN LED Color Definition The stacked Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED states 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Right LED 10 Mbps Link Green Off Active Blinking Green Off 100 Mbps Link Green Green Active Blinking Green Green 1000 Mbps Lin...

Страница 46: ... 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V 2 14 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect of your computer Before closing up your chassis make sure that all cables and wires are connected properly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set corre...

Страница 47: ...s and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed memory called NVRAM that retains the information even when the power is turn...

Страница 48: ...or best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic look and function of the BIOS setup remains more or less the same for most systems the appearance of your Setup screen may differ from the charts shown in ...

Страница 49: ...re for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Memory Information This displays the total memory size System Date Adjust the system date MM Months DD Days YYYY Years System Time Adjust the system clock HH 24 hours format MM Minutes SS Seconds Access Level Read only ...

Страница 50: ...Computing Trusted Computing Settings ACPI Settings System ACPI Parameters Onboard Device Configuration Onboard Device Configuration Hardware Health Configuration Hardware health Configuration Parameters Super IO Configuration System Super IO Chip Parameters S5 RTC Wake Settings Enable system to wake from S5 using RTC alarm ...

Страница 51: ...Configuration Parameters SATA Configuration SATA Devices Configuration PCI Subsystem Settings PCI PCI X and PCI Express Settings CSM Configuration CSM configuration Enable Disable Option ROM execution settings etc NVMe Configuration NVMe Device Options Settings USB Configuration USB Configuration Parameters ...

Страница 52: ...om 52 3 3 1 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1a interface will not be available Enabled Disabled ...

Страница 53: ...http www tyan com 53 3 3 2 ACPI Settings ACPI Sleep State Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed Suspend Disabled S3 Suspend to RAM ...

Страница 54: ...3 4 Option ROM Enable Disable Load Option ROM for LAN Devices Disabled Enabled with PXE Enabled with iSCSI Load Onboard LAN 2 3 Option ROM Enable Disable Load Option ROM for LAN Devices Disabled Enabled with PXE Load Onboard LAN 4 Option ROM Enable Disable Load Option ROM for LAN Devices Disabled Enabled with iSCSI Chassis Intrusion detect Enabled When a chassis open event is detected the BIOS wil...

Страница 55: ...http www tyan com 55 Disabled Enabled NMI function Enable or Disable NMI button Disabled Enabled PMBus Support PMBus Support Enabled Disabled Number of PSU Number of PSU 1 1 1 ...

Страница 56: ...http www tyan com 56 3 3 4 Hardware Health Configuration Auto Fan Control Auto Fan Control Help Disabled Enabled BMC Alert Beep BMC Alert Beep On Off Off On ...

Страница 57: ...http www tyan com 57 3 3 4 1 Sensor Data Register Monitoring Read only ...

Страница 58: ...http www tyan com 58 3 3 5 Super IO Configuration Super IO Chip Read only ...

Страница 59: ...le or Disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 ...

Страница 60: ...pecified Select Dynamic Time system will wake on the current time increase minute s Disabled Fixed Time Dynamic Time Wake system from S5 when set to Fixed time Wake up hour Select 0 23 For example enter 3 for 3am and 15 for 3pm 0 Wake up minute Select 0 59 0 Wake up second Select 0 59 0 Wake system from S5 when set to Dynamic time Wake up minute increase Select 1 5 1 ...

Страница 61: ... Enabled Serial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the host computer which the user is using will exchange data Both computers should have the same or compatible settings ...

Страница 62: ...t serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd Mark parity bit is alw...

Страница 63: ...F8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode On this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled Resolution 100x31 Enable or disable extended terminal resolution Disabled Enabled Legacy OS Redirection Resolution On Legacy OS the number of rows and columns supported redirection 80x24 80x...

Страница 64: ...http www tyan com 64 3 3 7 2 Legacy Console Redirection Settings Legacy Serial Redirection Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1 COM2 ...

Страница 65: ...erver OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission speed The speed must be matched on the other side Long or noisy lines m...

Страница 66: ...g data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS Software Xon Xoff Data Bits Parity Stop Bits Read only ...

Страница 67: ...sabled for other OS OS not optimized for Hyper Threading Technology When disabled only one thread per enabled core is enabled Enabled Disabled Active Processor Cores Number of cores to enable in each processor package All 1 Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Enabled Disabled ...

Страница 68: ...ed P states Enabled Disabled Intel R SpeedStep tm Allows more than two frequency ranges to be supported Enabled Disabled Turbo Mode Turbo Mode Enabled Disabled CPU C states Enable or disable CPU C states Enabled Disabled Enhanced C State Enable Disable C1E When enabled CPU will switch to minimum speed when all cores enter C State Enabled Disabled Package C State Limit Package C State Limit C0 C1 C...

Страница 69: ...de Selection Determines how SATA controller s operate AHCI RAID Hot Plug Designates this port as Hot Pluggable Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State Drive ...

Страница 70: ...www tyan com 70 3 3 10 PCI Subsystem Settings Above 4G Decoding Enables or Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding Disabled Enabled ...

Страница 71: ...p Current INT19 Trap Response BIOS reaction on INT19 trapping by Option ROM IMMEDIATE execute the trap right away POSTPONED execute the trap during legacy boot Immediate Postponed Boot option filter This option controls Legacy UEFI ROMs priority UEFI and Legacy Legacy only UEFI only Network Controls the execution of UEFI and Legacy PXE OpROM Legacy Do not launch UEFI ...

Страница 72: ...and Legacy Storage OpROM Legacy Do not launch UEFI Video Controls the execution of UEFI and Legacy Video OpROM Legacy Do not launch UEFI Other PCI Devices Determines OpROM execution policy for devices other than Network Storage or Video Legacy Do not launch UEFI ...

Страница 73: ...http www tyan com 73 3 3 12 NVMe Configuration Read only ...

Страница 74: ...devices are connected DISABLE option will keep USB devices available only for EFI applications Enabled Disabled Auto Port 60 64 Emulation Enables I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support for non USB aware OSes Enabled Disabled USB transfer time out The time out value for Control Bulk and Interrupt transfers 20 sec 1 sec 5 sec 10 sec ...

Страница 75: ...t command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Auto Manual ...

Страница 76: ...http www tyan com 76 3 4 Chipset Menu Intel Server Platform Services Intel Server Platform Services Parameters North Bridge System Agent SA Parameters South Bridge PCH Parameters ...

Страница 77: ...Server Platform Services Help Enabled Disabled Power Measurement support When set to Enable the Power Thermal Utility for EFI is supported by platform Disabled Enabled Hardware change detected When set to Enable Intel ME stops power limiting in order to facilitate the platform characterization Disabled Enabled ...

Страница 78: ...http www tyan com 78 3 4 2 North Bridge Configuration VT d VT d capability Enabled Disabled eDRAM Mode SW Mode eDRAM ON or eDRAM Off eDRAM HW Mode SW Mode eDRAM Off SW Mode eDRAM On ...

Страница 79: ...t will not scan for External Gfx Card on PEG and PCH PCIE Ports Disabled Enabled Primary Display Select which of IGFX PEG PCI Graphics device should be Primary Display Or select SG for Switchable Gfx Auto PEG PCIE Primary PEG Select PEG0 PEG1 PEG2 PEG3 Graphics device should be Primary PEG Auto PEG11 PEG12 ...

Страница 80: ...4 F5 F6 F7 PCIE8 PCIE9 PCIE10 PCIE11 PCIE12 PCIE13 PCIE14 PCIE15 of D29 F0 F1 F2 F3 F4 F5 F6 F7 PCIE16 PCIE17 PCIE18 PCIE19 of D27 F0 F1 F2 F3 Graphics device should be Primary PCIE Auto PCIE1 PCIE2 PCIE3 PCIE4 PCIE5 PCIE6 PCIE7 PCIE8 PCIE9 PCIE10 PCIE11 PCIE12 PCIE13 PCIE14 PCIE15 PCIE16 PCIE17 PCIE18 PCIE19 ...

Страница 81: ...m 81 3 4 2 2 Memory Configuration Submenu Memory RC Version Memory Frequency Total Memory VDD DIMM_A0 DIMM_A1 DIMM_B0 DIMM_B1 Read only Maximum Memory Frequency Maximum Memory Frequency selections in Mhz Auto 1866 2133 ...

Страница 82: ... ID Read only DeepSx Power Policies Configure the DeepSx Mode configuration Disabled Enabled in S4 S5 High Precision Timer Enable or Disable the High Precision Event Timer Enabled Disabled Restore AC Power Loss Select AC power state when power is re applied after a power failure Power Off Power On Last State ...

Страница 83: ... Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation ...

Страница 84: ...mer Enable or Disable FRB 2 timer POST timer Disabled Enabled FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value 6 minutes 3 minutes 4 minutes 5 minutes FRB 2 Timer Policy Configure how the system should respond if the FRB 2 timer expires Not available if FRB 2 Timer is disabled No Nothing Reset Power Down Power Cycle ...

Страница 85: ...OS Boot Watchdog Timer policy Disabled Enabled OS Wtd Timer Timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog Timer is disabled 10 minutes 5 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled Reset Do Nothing Power Down Power Cy...

Страница 86: ...ically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Current Configuration Address Source Station IP address Subnet mask Station MAC address Router IP address Router MAC address Read only 3 5 1 CSM16 Parameters ...

Страница 87: ...http www tyan com 87 eINT19 Trap Response BIOS reaction on INT19 trapping by Option ROM Immediate execute the trap right away Postponed execute the trap during the legacy boot Immediate Postponed ...

Страница 88: ...http www tyan com 88 3 5 2 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to Delete Device Name ...

Страница 89: ...onds to wait for setup activation key 65535 0xFFFF means indefinite waiting 2 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Boot Option 1 Sets the system boot order Device Name Disabled ...

Страница 90: ...ot Disabled Enabled Wait for ESC If Error Enable or Disable Wait ESC key Function When Chassis intrusion CMOS Clear or BMC not Response Enabled Disabled New Boot Option Policy Controls the placement of newly detected UEFI boot options Default Place First Place Last ...

Страница 91: ...tem setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Options Read only Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of the setup options ...

Страница 92: ...om 92 Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options ...

Страница 93: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard please check the TYAN web site at http www tyan com NOTE Please be aware that by flashing your BIOS you agree that in the event of a BIOS flash failure you must contact your dealer for a replacement BIO...

Страница 94: ... 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Not used Progress Codes 0x01 Power on Reset type detection soft hard 0x02 AP initialization before microcode loading 0x03 North Bridge initialization before microcode loading 0x04 South Bridge initialization be...

Страница 95: ...mory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module specific 0x1D 0x2A OEM pre memory initialization codes 0x2B Memory initialization Serial Presence Detect SPD data reading 0x2C Memory initialization Memory presence detection 0x2D Memory initialization...

Страница 96: ...Memory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 Unspecified memory initialization error 0x55 Memory not installed 0x56 Invalid CPU type or speed 0x57 CPU mismatch 0x58 CPU self test failed or possible CPU cache error 0x59 CPU microcode is not found ...

Страница 97: ...d twice InstallPEIMemory routine in PEI Core called twice 2 Recovery started 3 DXEIPL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available DXE Phase Status Code Description 0x60 DXE Core is started 0x61 NVRAM initialization 0x62 Installation of the South Bridge Runtime Services 0x63 CPU DXE initialization is started 0x64 CPU DXE i...

Страница 98: ...th Bridge DXE initialization South Bridge module specific 0x77 South Bridge DXE initialization South Bridge module specific 0x78 ACPI module initialization 0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bus initialization is started 0x93 PCI Bus Hot...

Страница 99: ...xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes DXE Error Codes 0xD0 CPU initialization error 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Res...

Страница 100: ...iption 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waking up from the S2 sleep state 0x30 System is waking up from the S3 sleep state 0x40 System is waking up from the S4 sleep state 0x...

Страница 101: ...r readers reference NOTE The red mark indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed rpm 2 Temp Sensor Sys_Air_Outlet Sys_Air_Inlet on the front panel board SAS_Area_Temp PCH_Temp and MB_Air_Inlet They detect the system temperature around NOTE The system temperature is measured in a scale defined by Int...

Страница 102: ... 102 BIOS Temp Sensor Name Explanation BIOS Temp Sensor Name Explanation Sys_Air_Outlet Temperature of System Air Outlet Area SAS_Area_Temp Temperature of LSI3008 Area Sys_Air_Inlet Temperature of System Air Inlet Area ...

Страница 103: ...MM_B0 Temperature of CPU DIMM B0 Slot CPU_DIMM_B1 Temperature of CPU DIMM B1 Slot CPU Fan Fan Speed of CPU Fan SYS_FAN_1 Fan Speed of System Fan1 SYS_FAN_2 Fan Speed of System Fan2 SYS_FAN_3 Fan Speed of System Fan3 SYS_FAN_4 Fan Speed of System Fan4 SYS_FAN_5 Fan Speed of System Fan5 SYS_FAN_6 Fan Speed of System Fan6 SYS_FAN_7 Fan Speed of System Fan7 SYS_FAN_8 Fan Speed of System Fan8 SYS_FAN_9...

Страница 104: ...http www tyan com 104 NOTE ...

Страница 105: ...B serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in greater speed BBS BIOS Boot Specification a feature within the BIOS that creates prioritizes and maintains a list of all Initial Program Load IPL devices and then stores that list in NVRAM IPL devic...

Страница 106: ...eight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on eight different wires at the same time that is in parallel form eight bits at the same time DDR Double Data Rate a technology designed to double the clock speed of the memory It activates output on bo...

Страница 107: ...tware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form factors are the AT and ATX Global timer onboard hardware timer such as the Real Time Clock RTC HDD stands for Hard Disk Drive a type of fixed drive H SYNC controls the horizontal synchronization pro...

Страница 108: ...faster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data transfer modes used by IDE drives These modes use the CPU for data transfer in contrast DMA channels do not PCI refers to the type of bus used by these modes to communicate with the CPU PCI to PCI Bridge ...

Страница 109: ...e it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronous RAM which must close one address bank before opening the next Serial port called as such because it transmits the eight bits of a byte of data along one wire and receives data on another single wir...

Страница 110: ...board or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC controls the vertical scanning properties of the monitor ZCR Zero Channel RAID PCI card that allows a RAID card to use the onboard SCSI chip thus lowering cost of RAID solution ZIF Socket Zero Insert...

Страница 111: ...mprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system components to keep their systems running as powerful and productive as possible TYAN also ranks high for its commitment to fast and friendly customer support through email By offering plenty of options for u...

Страница 112: ...nt or relocate the receiving antenna Increase the separation between the equipment and the receiver Plug the equipment into an outlet on a circuit different from that of the receiver Consult the dealer on an experienced radio television technician for help Notice for Europe CE Mark This product is in conformity with the Council Directive 2014 30 EU Warning This equipment is compliant with Class A ...

Отзывы: