(11) SELectSPeed?
Command to request for setting of Speed Table of each axis.
<Response Data>
Content
0~9
Number of Speed Table in selection process
(12) STANDARDresolution?
Command to request for standard resolution of motorized stage (travel distance per pulse at full
step) for each axis.
<Response Data> is 0.0000001~99999999.
(13) UNIT?
Command to request for setting of Display Unit of each axis.
<Response Data>
Content
0
Setting a unit of pulse
1
Setting a unit of μm
2
Setting a unit of mm
3
Setting a unit of deg
4
Setting a unit of mrad
(14) TeaCH00? ~ TeaCH63?
Command to request for teaching point. Return 6 axes data
<Response Data format> □1/□2/□3/□4/□5/□6
<Response Data>
Content
□1
Xaxis data : -99999999~99999999、-9.9999999~9.9999999
Xaxis data unset : N
□2
Yaxis data : -99999999~99999999、-9.9999999~9.9999999
Yaxis data unset : N
□3
Zaxis data : -99999999~99999999、-9.9999999~9.9999999
Zaxis data unset : N
□4
Uaxis data : -99999999~99999999、-9.9999999~9.9999999
Uaxis data unset : N
□5
Vaxis data : -99999999~99999999、-9.9999999~9.9999999
Vaxis data unset : N
□6
Waxis data : -99999999~99999999、-9.9999999~9.9999999
Waxis data unset : N
4.3.5.9 Memory SW Setting Request Command
This command requests for setting of Memory SW 0 (Origin Return type), 1 (Mechanical Limit Sensor
Input Logic), 2 (Origin Sensor Input Logic), 3 (Near Origin Sensor Input Logic), 4 (Current Down
Control), 5 (Motion Direction Switching), 6(Stop processing) and 7(Origin Return 0 Reset).
No sooner was request command received, than it send response value to the requirement.
※
Connecting Axis Selection command is available.
※
Use : (colon) to connect commands.
※
Orders of connection have to begin with Axis Selection Command: Memory SW setting
Request Command.
Memory SW Setting Request Command is configured as shown below:
・
When selecting axis and requesting Memory SW setting.
Axis Selection Command <Data>:Memory SW Setting Request Command?