background image

7

WARNING FIRE HAZARD

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. 
All exhaust must be ducted to the outside, unless using the recirculating option.

Use single wall rigid Metal ductwork only.

Fasten all connections with sheet metal screws and tape all joints w/ certifi ed Silver Tape or Duct Tape.

Some Ducting Options

Installation – 

Ducting Options

side wall cap
w/ gravity damper

Soffit or crawl space

Roof Pitch w/ 

Flashing & Cap

ductless
recirculating

side wall cap
w/ gravity damper

Содержание MH00130CS

Страница 1: ...MODEL MH00130CS MH00136CS 2014 SEP READ AND SAVE THESE INSTRUCTIONS Installation Use and Care Guide ...

Страница 2: ...www build com ...

Страница 3: ...g Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Mechanical Controls 11 MAINTENANCE Hood and Filter Cleaning 12 Light Bulbs 13 TROUBLESHOOTING 14 WIRING DIAGRAMS 15 LIST OF PARTS AND ACCESSORIES 16 Table of Contents ...

Страница 4: ...r the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c D...

Страница 5: ... conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a quali ed electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a quali ed electrician ...

Страница 6: ... Extension duct cover accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS 1 Light Bulb Removal Suction Cup PARTS SUPPLIED MODELS MH00130CS MH00136CS 1 Hood with internal blower 1 Duct cover wall bracket 1 Duct cover assembly top and bottom 1 Hardware package 1 6 round backdraft damper pre installed 2 50W GU 10 halogen light bulbs 2 Aluminum mesh filters ...

Страница 7: ...lent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangul...

Страница 8: ...sult in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 16 for par...

Страница 9: ...de unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating side wall cap w gravity damper ...

Страница 10: ...tion Hood Specifi cations 2 2 2 9 24 27 4 8 27 3 26 27 9 4 5 7 8 9 23 2 4 5 5 2 4 46 8 9 Standard Duct Cover Min ducted 27 1 2 Min recirc 32 Max ducted 42 1 2 RHEX001S Extension Min ducted 46 1 2 Min recirc 50 1 2 Max ducted 80 ...

Страница 11: ...ng 2 M6x1 screws 8 Install electrical 9 Install duct work and duct tape 10 Power up hood and check for leaks around duct tape 11 Place telescopic duct covers onto hood and extend inner top duct cover upwards and secure to duct cover bracket using 2 M4x3 8 screws if using hood in recirculating mode you must secure air diverter plate onto wall before installing duct work and duct covers Turn to page...

Страница 12: ...ion RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal lters charcoal lter brackets and air diverter plate Hood Model Part No Filters Brackets in Pkg MH00130CS MH00136CS RHRK001S 2 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to wall below duct cover bracket FIG B Run 6 ducting from top of hood and secure to air diverter plate 3 Remove the ...

Страница 13: ...11 1 3 3 Features Controls Mechanical Controls ...

Страница 14: ...clean cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Metal Mesh Filters The metal mesh filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing detergent a...

Страница 15: ...ve by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the provided glass suction cup to the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For part numbers please turn to page 16 o...

Страница 16: ... g n a h C 5 r o t i c a p a c d e g a m a D 5 h c t i w s e h t e g n a h C 6 e v i t c e f e d s i h c t i w s e h T 6 The unit is vibrating 1 The blower is not secured in place 1 Tighten the blower in place r e w o l b e h t e c a l p e R 2 l e e h w r e w o l b d e g a m a D 2 3 The hood is not secured in place 3 Check the installation of the hood The blower is working but the lights are not 1...

Страница 17: ...15 Wiring Diagrams A A ...

Страница 18: ... Bulb GU 10 50W each Z0B 0020 Optional Accessories Recirculating Kit RHRK001S Replacement Charcoal Filter each RHCF001 Extension Duct Cover RHEX001S To order parts email us at vsupport ventingservices com or call us at 1 888 750 1698 List of Parts Accessories ...

Страница 19: ... you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SE...

Отзывы: