MIOX RIO Zuni™ Operators Manual
P/N: 102-00094-I
Page 24
USB
A USB memory stick can be plugged into the USB port on the back panel at any time to log
the system’s status and operational parameters. The log is stored in a dated text file on the
memory stick and any readily available memory stick should be able to log months of
operation without any issues. The headers for the log are not included but are available
through your sales representative or service provider. MIOX recommends always restarting
the unit after plugging in a USB memory stick.
NOTE: MIOX recommends using a new, dedicated USB memory stick
for any data logging to prevent any unexpected file interactions with
the RIO Zuni OSG.
Ethernet
To remotely monitor the system over Ethernet, an Ethernet cable must be connected from
the back of the unit to an existing Ethernet network that supports DHCP. The system will
periodically display its assigned IP address after the priming cycle completes. System data
may be viewed remotely through any modern web browser; enter the IP address
periodically displayed by the system into your web browser’s address bar. The webpage is
served with data in the form of an .xml file, while it is possible to parse this data with some
modern SCADA systems this feature is not supported.
Troubleshooting
Fault Conditions
The RIO Zuni is preprogrammed with a number of fault conditions which trigger whenever
the system is running atypically. The faults are classified as either hard or soft faults. Hard
faults automatically shut the system down and require a power cycle to reset the system.
Soft faults try to resolve themselves and automatically restart the system a number of
times before requiring a power cycle reset.
Fault
Fault
Type
# of
Restarts
Cause
Oxidant Tank Level
Error
Hard
0
Level Switches are in an invalid position (Low level
switch is low while high level switch is high)
Very High Current
Hard
0
Cell current has surpassed 125% of target current
Very High Oxidant Temp Hard
0
Oxidant temp measured above 145°F (62°C)
Delta Temp
Soft
3
Measured temperature rise across cell has surpassed
50°F (27°C)
Low Feed Water Temp
Soft
1
Inlet water temp measured below 33°F (1°C)
High Brine Pump Duty
Soft
3
Brine pump usage over 250% of normal
Table 2: Fault conditions descriptions
Resolving Software Faults
The only way to clear a fault from the system is to reset it by cycling power as described in
step 14) of the installation instructions. This resetting will rerun the priming cycle and flush
the cell before restarting. Please note that restarting the system does not necessarily mean
the problem will go away, only that the unit will try to resume normal operation. If the unit
still cannot resume normal behavior, the system will continue to fault after the
Содержание RIO Zuni 1
Страница 18: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 18 Figure 8 RIO Zuni Connections...
Страница 35: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 35...
Страница 36: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 36...
Страница 37: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 37...
Страница 38: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 38...
Страница 39: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 39...