background image

27

26

(These items may require optional software or hardware)

Function

Factory
Default

Description

User Choices

Set
inverter
output
voltage

Shut-

down

Type

Set

audible

alarm

state

Enable/

Disable

auto

restart

Battery

life in

days

Battery

install

date

UPS ID Enterprise

Plus Series

Date of

manufacture

1826

Enabled

Enabled

Entire UPS

120VAC

(208VAC)

Up to 64 charac-

ters to define the

UPS

Date of battery

replacement -

month/day/year

XX/XX/XXXX

Up to 5

characters

Enable

or

Disable

Enabled, at

low battery,

disabled

Entire UPS  or

UPS output

120, 125VAC

(208, 240VAC)

At first battery replacement, re-
set to reflect actual number of
days experience in your environ-
ment or leave factory default

Enter the current date when

replacing batteries

Use this function to uniquely

identify the UPS in your network

configuration

Changes output voltage for bat-

tery mode operation

Enabled - the UPS will emit a short

beep when in the battery mode.

At Low Battery  the UPS will emit

two beeps from low   battery warn-

ing until shutdown.

Disabled - Use only when software

is controlling the UPS or to

silence the alarm

When  enabled, the UPS will

automatically restart from a low

battery shutdown when normal AC

returns

Enable/

Disable

REPO

Disabled

Enable

or

Disable

Enabled - the UPS will be

powered off and  remain off until

the UPS is reset

Entire UPS - Turns off the entire  UPS.
UPS Output -  Turns off the UPS's
output receptacles only.

Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and
operated within specified conditions, against faulty materials or workmanship for a period
of three years from the date of purchase.  For equipment sites within the United States and
Canada, this warranty covers depot repair or replacement of defective equipment at the
discretion of Para Systems.  Depot repair will be from the nearest authorized service cen-
ter.  The customer pays for shipping the product to Para Systems.  Para Systems pays
ground freight to ship the product back to the customer.  Replacement parts and warranty
labor will be borne by Para Systems.  For equipment located outside of the United States
and Canada, Para Systems only covers faulty parts.  Para Systems products that are
depot repaired or replaced pursuant to this warranty shall only be warranted for the unex-
pired portion of the warranty applying to the original product.  This warranty applies only to
the original purchaser who must have properly registered the product within 10 days of
purchase.

The warranty shall be void if (a) the equipment is damaged by the customer, is improperly
used, is subjected to an adverse operating environment, or is operated outside the limits of
its electrical specifications; (b) the equipment is repaired or modified by anyone other than
Para Systems or Para Systems approved personnel; or (c) has been used in a manner
contrary to the product’s User's Manual or other written instructions.

Any technical advice furnished before or after delivery in regard to use or application of
Para Systems’ equipment is furnished without charge and on the basis that it represents
Para Systems’ best judgment under the circumstances, but it is used at the recipient’s sole
risk.

EXCEPT AS PROVIDED HEREIN, PARA SYSTEMS MAKES NO WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.  Some states do not permit limitation of implied warranties; there-
fore, the aforesaid limitation(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING
OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGE.  Specifically, Para Systems is not liable for any costs, such as; labor for on-site
installation, on-site maintenance or on-site service, lost profits or revenue, loss of equip-
ment, loss of use of equipment, loss of software, loss of data, cost of substitutes, claims by
third parties, or otherwise.  The sole and exclusive remedy for breach of any warranty,
expressed or implied, concerning Para Systems’ products and the only obligation of Para
Systems hereunder, shall be depot repair or replacement of defective equipment, compo-
nents, or parts; or, at Para Systems’ option, refund of the purchase price or substitution
with an equivalent replacement product.  This warranty gives you specific legal rights and
you may also have other rights which vary from state to state.

No employee, salesman, or agent of Para Systems is authorized to add to or vary the terms
of this warranty.

Содержание Enterprise Plus LCD RTXL UPS Series

Страница 1: ...r s Manual Enterprise Plus LCD RTXL UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000431...

Страница 2: ...s and Indicators 6 3 Installation 9 4 Operation 15 5 Troubleshooting 19 6 Replacing the Battery 20 7 Obtaining Service 23 8 Specifications 24 9 Configurable Parameters Settings 26 10 Limited Product W...

Страница 3: ...ouble free service Please read this manual before installing your Enterprise Plus Series UPS models E750RTXL2U E1000RTXL2U E1500RTXL2U E1500RTXLT2U E2000RTXL2U E3000RTXL2U E3000RTXLT2U as it provides...

Страница 4: ...ce in a residential installation This equip ment generates and uses radio frequency and if not installed and used properly that is in strict accordance with the manufacturer s instructions this equip...

Страница 5: ...l be illuminated and the UPS will sound a constant alarm to indicate that there is an Overload condi tion The Battery Capacity Bar Graph operates as follows LED 1 When the battery capacity is 20 the L...

Страница 6: ...ction Labeled Load 1 Load 2 The locking and Always On receptacles Labeled Load 3 do not support the Load Shed ding Function NOTE The locking recptacle is not on all models 7 The input circuit breaker...

Страница 7: ...tteries is complete See Connecting your Equipment NOTE If you are using an External Battery Pack with this UPS series the UPS must be configured so that the UPS will report the correct estimated runti...

Страница 8: ...e UPS On the backside of the front panel push the LCD panel out wards the panel will pop out Position the LCD panel so that it reads in the up right position Re install the front panel on the UPS 8 Th...

Страница 9: ...e T network single line phone Fax or Modem line to the RJ11 45 modular connectors on the rear panel of the UPS This connection will require another length of telephone or network cable The cable comin...

Страница 10: ...ad 1 Load 2 The user can control the two segments individually or both at the same time The Load Shedding Function is controllable by the Power Monitoring Software or the SNMP card NOTE The output seg...

Страница 11: ...ps after UPS restarts reduce the load on the UPS UPS operates in battery mode only even though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cabl...

Страница 12: ...e impact on battery life NOTE If there is a power interruption while replacing the hot swappable batteries with the UPS on the load will not be backed up BATTERY REPLACEMENT PROCEDURE PLEASE READ THE...

Страница 13: ...mation about your unit d The serial number of your unit e Any information on the failure including LEDs that may be illuminated or error codes displayed f A description of the protected equipment incl...

Страница 14: ...arge cycles and ambient temp BM0029 BM0030 8 hours to 90 after full load discharge BM0031 Battery Type Sealed Non Spillable Maintenance Free Value Regulated LeadAcid System Voltage Runtime Full Load m...

Страница 15: ...ems products that are depot repaired or replaced pursuant to this warranty shall only be warranted for the unex pired portion of the warranty applying to the original product This warranty applies onl...

Страница 16: ...UPS Model No E750RTXL2U Y E1000RTXL2U Y E1500RTXL2U Y E2000RTXL2U Y E3000RTXL2U Y E1500RTXLT2U Y E3000RTXLT2U Y I hereby declare that the equipment specified above conforms to the above Directive s P...

Отзывы: