background image

11

10

RACKMOUNT CONFIGURATION

This UPS series comes with mounting brackets for the standard 19" (46.5cm)
rack pre-installed on the UPS.  The mounting brackets to fit a 23" (59.2cm)
rack and Rail Kits for 4-post racks and cabinets are also available.  The
screws for mounting the UPS to the rack are included.  

NOTE:  

The Rail Kits

for a 4-post rack and/or cabinet are included with the ED3000RTXL2U.

CAUTION!  

DO NOT USE THE MOUNTING BRACKETS TO LIFT THE

UPS.

  The mounting brackets are 

ONLY

 for securing the UPS to the rack.

NOTE:

  The mounting brackets can be mounted in the middle of the UPS.

1. Mount the UPS into the rack and secure with the retaining screws.

  WARN-

ING:  

Use two or more people when installing the UPS, the UPS is extrem-

ely heavy.  Do not move the rack after the units have been installed.  The
rack may become unstable due to the weight distribution.

2. The Rackmount Configuration is complete. See Connecting your Equipm-

ent.

CONNECTING THE BATTERIES

(QUALIFIED

 

SERVICE PERSONNEL ONLY)

Please read all of the 

WARNINGS

 and 

CAUTIONS

 before attempting to con-

nect the batteries.

WARNING:  

Use two or more people when installing the UPS, the UPS is

extremely heavy.
1. Remove the UPS from the shipping box.
2. Place the UPS on a flat surface and then remove the front panel retaining

screws.

3. Lay the front panel on top of the UPS.
4. Verify proper polarity.  Connect the battery connectors (red and black)

together.

NOTE:

Some sparking may occur this is normal.

5. Re-install the front panel onto the UPS.
6. Re-install the front panel retaining screws.
7. Connecting the Batteries is complete.  See the Rackmount Configuration.

CAUTION!  

DO NOT USE THE MOUNTING BRACKETS TO LIFT THE

UPS.

  The mounting brackets are 

ONLY

 for securing the UPS to the rack.

Содержание ED3000RTXL2U

Страница 1: ...User s Manual Endeavor LCD RTXL UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000516 R2...

Страница 2: ...6 3 Installation 9 4 Operation 15 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Страница 3: ...k Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected CAUTION To reduce the risk of electrical shock in conditions where the load equ...

Страница 4: ...3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where failure or malf...

Страница 5: ...ght will turn on and remain on to alert the user that an event has occurred Chapter 2 Controls and Indicators The UPS output is off bPS EPo RPo E24 ECo PAS off The UPS output has been turned on The UP...

Страница 6: ...he locking and Always On receptacles Lab eled Load 3 do not support the Load Shedding Function NOTE The lo cking recptacle is not on all models 8 The input circuit breaker will trip in the event the l...

Страница 7: ...e units have been installed The rack may become unstable due to the weight distribution 2 The Rackmount Configuration is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERV...

Страница 8: ...ng screws Slide the UPS down until its resting securely on the four retaining s crews 7 Tighten the four retaining screws to secure the UPS to the wall 8 The Wallmount Configuration is complete See Co...

Страница 9: ...PTIONAL Connect one end of the RJ11 cable to the EPO port and the other end of the RJ11 cable to the EPO switch In the AC or the Battery mode short pin4 to pin5 for approximately 0 5 seconds to shutdo...

Страница 10: ...ad 3 does not support the Load Shed ding Function TURNING THE UNIT ON OFF On Off Test Button When the UPS is connected to an AC source and there is an acceptable AC volt age present Press and release...

Страница 11: ...are using an External Battery Pack with this UPS series the UPS must be configured so that the UPS will report the correct estimated runtime on the LCD screen and in the Power Monitoring software and...

Страница 12: ...n though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cable from the UPS press the On but ton If UPS works normally the software has control of...

Страница 13: ...f batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the batteries properly The batteries contain lead and pose a hazard to the environment and human hea...

Страница 14: ...ent Short Circuit Protected and Latching Shutdown True Sine Wave Frequency 50 60Hz 0 5Hz unless synchronized to utility Nominal Voltage Adjustable Maximum Power Capacity 0 ms Typical 90 Full Load Rese...

Страница 15: ...cus tomer pays for shipping the product to Para Systems Para Systems pays ground freight to ship the product back to the customer Replacement parts and warranty labor will be borne by Para Systems For...

Страница 16: ...XL2U Y ED3000RTXL2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date February 1 2017 Robert Calhoun Name Manager Engineering Posi...

Отзывы: