2

the plug is removed to simulate a power failure (not recommended), do not touch the plug
conductors or the chassis while the lug is removed.

  CAUTION -- Do not allow water or any foreign object to enter the UPS.  In case this

occurs, immediately turn the unit power switch off and unplug the MINUTEMAN from the
commercial receptacle.

  Servicing of batteries should be performed or supervised by personnel knowledgeable of

batteries and the required precautions.  Keep unauthorized personnel away from the
batteries.

  When replacing UPS batteries, use sealed lead-calcium rechargeable batteries with the

same voltage and ampere-hour rating as those contained in the units.  These batteries
have pressure operated safety vents.

  CAUTION

1.  Do not dispose of batteries in a fire.  They may explode.

2.  Do not open or mutilate batteries.  Released electrolyte is harmful to the skin and

eyes, and may be toxic.

3.  Battery systems can present a risk of electrical shock and high short circuit current.

The current capability of each battery system is sufficient to burn large wire or tools
very rapidly, producing molten metal.  The following precautions should be observed
when working on batteries:

a.  Disconnect charging source prior to connecting or disconnecting battery

terminals.

b.  Remove watches, rings or other metal objects.

c.  Use tools with insulated handles.

d.  Do not lay tools or any metal parts on top of batteries.

e.  Wear protective gloves, eyewear, and boots.

f. 

Determine if the battery is inadvertently grounded.  If inadvertently grounded,
remove source of ground.  Contact with any part of a grounded battery can
result in an electrical shock.  The likelihood of such shock will be reduced if
such grounds are removed during installation and maintenance.

SELECTION OF UPS LOCATION

Select a location that will provide good air circulation for the UPS.  Do not cover the unit air vent
holes or restrict airflow in any way.  The unit must have good air circulation at all times.

  Avoid locations near heating devices.

  Avoid locations near water or excessive humidity.

  Avoid locations where the unit is exposed to direct sunlight.

Содержание AT1200

Страница 1: ...MODELS DESCRIBED IN THIS MANUAL AT650 GS650 650VA AT800 GS800 800VA AT1200 GS1200 1200VA AT1600 GS1600 1600VA AT2300 GS2300 2300VA OWNER S MANUAL...

Страница 2: ...Physical Specifications 4 Unit Description 5 GS Models 6 Installation and Preliminary Testing 6 Load Testing 7 Operation 7 System Batteries 8 Battery System Checkout 9 UPS Monitoring Configurations 9...

Страница 3: ...TRATION Locate your warranty registration card in the back of this manual and complete and return within 10 days of receipt of the unit s to register your warranty Failure to register your warranty re...

Страница 4: ...igh short circuit current The current capability of each battery system is sufficient to burn large wire or tools very rapidly producing molten metal The following precautions should be observed when...

Страница 5: ...00 800 560 50 220 4 0 220 3 6 48 8 20 382 AT1200 1200 840 60 120 11 1 120 10 0 48 7 18 573 GS1200 1200 840 50 220 6 1 220 5 5 48 7 18 573 AT1600 1600 1120 60 120 14 8 120 13 3 72 8 20 765 GS1600 1600...

Страница 6: ...er Crest Factor Non Linear Load 3 1 Inverter Waveform Synchronized Computer Grade Sinewave Harmonic Distortion Less than 3 THD at full linear load Inverter Voltage Regulation Static 3 Dynamic 5 with 5...

Страница 7: ...Audible Noise 40 dB ANSI Scale A at 3 UNIT DESCRIPTION AT SYCHRONIZED SINEWAVE MODELS 1 Power Switch 2 Alarm Silencer Test momentary rocker switch 3 AC Normal LED Green On when commercial voltage is...

Страница 8: ...15P Plug standard or AWG 12 3 SJT AT2300 with NEMA L5 30P Plug 11 Input Fuse Holder Breaker At650 AT800 and AT2300 units use fuse and fuse holder at input AT1200 and AT1600 units use AC circuit break...

Страница 9: ...r This testing should be repeated 5 to 10 times 3 Verify that UPS and load functions were proper during this testing see items under INSTALLATION AND PRELIMINARY TESTING for UPS function If all functi...

Страница 10: ...y warning IF COMMERCIAL POWER RETURNS BEFORE THE WARNING SIGNAL THERE IS NO NEED TO SHUT DOWN YOUR SYSTEM AT ALL The MINUTEMAN will switch back to normal AC mode operation automatically During normal...

Страница 11: ...ystems also offers its own software package Network Manage which functions with Novell Unix OS 2 LAN Manager LAN Server and MacIntosh Operating Systems Network Manager offers many advantages over exis...

Страница 12: ...mon problems Do not remove the unit cover or attempt to service this unit There are no user serviceable components inside Unauthorized service will void the warranty COMMON UPS PROBLEMS No normal AC m...

Страница 13: ...Other packaging methods can result in damage to the unit Enclose the name and telephone number of the person who can authorize repair charges inside the carton or packing list folder Also include you...

Страница 14: ...INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHER TYPES OR DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OTHER THAN THE LIABILITY STATED ABOVE THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR I...

Отзывы: