background image

1

INTRODUCTION

Congratulations on your purchase of a MINUTEMAN "AT" Series Synchronized Sinewave
Uninterruptible Power Supply (UPS).  Each unit is designed to provide superior, total power
protection for personal computers, telephone systems and any other sensitive or critical electronic
equipment against all commercial power anomalies.  These models provide light and audible
alarm indications, so the user will know the status of both commercial power and the
MINUTEMAN  "AT" Power Supply at all times.  Each unit is designed to be maintenance free and
to provide years of excellent service.  Other features of the "AT" Series include:

  Light weight and small footprint

 Quiet 

operation

  High non-linear current capability

(Crest Ratio = 3:1)

  Computer grade sinewave output

  LAN Communications Port

RECEIVING INSPECTION

Remove and inspect the unit for shipping damage.  If damage is found, immediately notify the
carrier and your dealer.  If no damage is found save both the shipping container and the packing
foam in case the unit may later need to be returned to the factory or shipped to another location.

WARRANTY REGISTRATION

Locate your warranty registration card in the back of this manual and complete and return within
10 days of receipt of the unit(s) to register your warranty.  Failure to register your warranty
renders it non-valid.

IMPORTANT SAFETY INSTRUCTIONS

(Save these instructions)

  Units in this manual are intended for installation in a temperature-controlled, indoor area

free of conductive contaminants.

  Read all instructions carefully before operating the UPS.  All operating instructions should

be followed and all cautions must be adhered to.

  CAUTION -- UPS units use batteries for generation of AC voltages, so output receptacles

may be electrically hot even when the unit is not connected to commercial power.
Trained service personnel should perform all repairs, since an electrical shock hazard
exists.

  CAUTION -- Do not remove the cover, there are no user serviceable parts inside.

  CAUTION -- The 3-wire plug supplied with the unit provides earth ground for the UPS

unit chassis to prevent electrical shock.  Plug the UPS unit into a 3-wire grounding type,
commercial receptacle with grounding conductor connected to earth ground at the
service equipment.  Removal

 

of the ground pin from the plug or use of a 3-wire-to-2-wire

adapter will defeat this safety feature and may result in a shock hazard.  Additionally, if

Содержание AT1200

Страница 1: ...MODELS DESCRIBED IN THIS MANUAL AT650 GS650 650VA AT800 GS800 800VA AT1200 GS1200 1200VA AT1600 GS1600 1600VA AT2300 GS2300 2300VA OWNER S MANUAL...

Страница 2: ...Physical Specifications 4 Unit Description 5 GS Models 6 Installation and Preliminary Testing 6 Load Testing 7 Operation 7 System Batteries 8 Battery System Checkout 9 UPS Monitoring Configurations 9...

Страница 3: ...TRATION Locate your warranty registration card in the back of this manual and complete and return within 10 days of receipt of the unit s to register your warranty Failure to register your warranty re...

Страница 4: ...igh short circuit current The current capability of each battery system is sufficient to burn large wire or tools very rapidly producing molten metal The following precautions should be observed when...

Страница 5: ...00 800 560 50 220 4 0 220 3 6 48 8 20 382 AT1200 1200 840 60 120 11 1 120 10 0 48 7 18 573 GS1200 1200 840 50 220 6 1 220 5 5 48 7 18 573 AT1600 1600 1120 60 120 14 8 120 13 3 72 8 20 765 GS1600 1600...

Страница 6: ...er Crest Factor Non Linear Load 3 1 Inverter Waveform Synchronized Computer Grade Sinewave Harmonic Distortion Less than 3 THD at full linear load Inverter Voltage Regulation Static 3 Dynamic 5 with 5...

Страница 7: ...Audible Noise 40 dB ANSI Scale A at 3 UNIT DESCRIPTION AT SYCHRONIZED SINEWAVE MODELS 1 Power Switch 2 Alarm Silencer Test momentary rocker switch 3 AC Normal LED Green On when commercial voltage is...

Страница 8: ...15P Plug standard or AWG 12 3 SJT AT2300 with NEMA L5 30P Plug 11 Input Fuse Holder Breaker At650 AT800 and AT2300 units use fuse and fuse holder at input AT1200 and AT1600 units use AC circuit break...

Страница 9: ...r This testing should be repeated 5 to 10 times 3 Verify that UPS and load functions were proper during this testing see items under INSTALLATION AND PRELIMINARY TESTING for UPS function If all functi...

Страница 10: ...y warning IF COMMERCIAL POWER RETURNS BEFORE THE WARNING SIGNAL THERE IS NO NEED TO SHUT DOWN YOUR SYSTEM AT ALL The MINUTEMAN will switch back to normal AC mode operation automatically During normal...

Страница 11: ...ystems also offers its own software package Network Manage which functions with Novell Unix OS 2 LAN Manager LAN Server and MacIntosh Operating Systems Network Manager offers many advantages over exis...

Страница 12: ...mon problems Do not remove the unit cover or attempt to service this unit There are no user serviceable components inside Unauthorized service will void the warranty COMMON UPS PROBLEMS No normal AC m...

Страница 13: ...Other packaging methods can result in damage to the unit Enclose the name and telephone number of the person who can authorize repair charges inside the carton or packing list folder Also include you...

Страница 14: ...INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHER TYPES OR DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OTHER THAN THE LIABILITY STATED ABOVE THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR I...

Отзывы: