background image

9

BATTERY /SYSTEM CHECKOUT

To verify proper system function and battery condition, the user is encouraged to engage the test
switch periodically.  Normal indications as specified should be observed.  If the system goes
immediately to the low battery-warning mode the batteries should be replaced.

UPS MONITORING CONFIGURATIONS

All of these models provide an UPS monitoring capability which will allow direct interface with
many different computer hardware/software configurations.  This capability permits an
unattended, orderly shut down of the computer system when commercial power is lost for a long
period.  Some configurations also provide for shut down of the UPS after the computer has been
shut down, thereby conserving UPS battery capability.

Following is a partial list of systems with which the monitoring capability exists.  Contact Para
Systems Customer Service Department for a more complete, up to date list.  In addition to those
standard configurations listed below, Para Systems also offers its own software package,
"Network Manage", which functions with Novell, Unix, OS/2, LAN Manager, LAN Server and
MacIntosh Operating Systems.  Network Manager offers many advantages over existing UPS
monitoring packages.

Finally, for systems which do not have UPS interface capability, user software can be written to
read UPS status and provide for system shut down.  Software specialists should contact Para
Systems, Inc. for more information.  The standard UPS DB9 PIN out is provided below for your
information.

UPS DIRECT INTERFACE CONFIGURATIONS

* Novell for AT compatible computers
  Novell for PS/2 computers with mouse port connector
  Altos Unix/Pick/Xenix with 1/4" stereo jack
  Same except for low battery warning response
  DTS Servers running Banyon Vines
  Servers running Banyon Vines
  Servers running Banyon Vines/286, Vines/386
  Prime 2350/2450
  Convergent/Unisys
  Microsoft LAN Manger
  Convergent Mighty Frame/Miniframe
  LANtastic

*This interface configuration functions with existing Novell UPS
monitoring board, SS keycard or Disk Coprocessor Board. Para Systems
Monitoring Board (MB1) is available for new installations which do not
already have an add on monitoring board.

Содержание AT1200

Страница 1: ...MODELS DESCRIBED IN THIS MANUAL AT650 GS650 650VA AT800 GS800 800VA AT1200 GS1200 1200VA AT1600 GS1600 1600VA AT2300 GS2300 2300VA OWNER S MANUAL...

Страница 2: ...Physical Specifications 4 Unit Description 5 GS Models 6 Installation and Preliminary Testing 6 Load Testing 7 Operation 7 System Batteries 8 Battery System Checkout 9 UPS Monitoring Configurations 9...

Страница 3: ...TRATION Locate your warranty registration card in the back of this manual and complete and return within 10 days of receipt of the unit s to register your warranty Failure to register your warranty re...

Страница 4: ...igh short circuit current The current capability of each battery system is sufficient to burn large wire or tools very rapidly producing molten metal The following precautions should be observed when...

Страница 5: ...00 800 560 50 220 4 0 220 3 6 48 8 20 382 AT1200 1200 840 60 120 11 1 120 10 0 48 7 18 573 GS1200 1200 840 50 220 6 1 220 5 5 48 7 18 573 AT1600 1600 1120 60 120 14 8 120 13 3 72 8 20 765 GS1600 1600...

Страница 6: ...er Crest Factor Non Linear Load 3 1 Inverter Waveform Synchronized Computer Grade Sinewave Harmonic Distortion Less than 3 THD at full linear load Inverter Voltage Regulation Static 3 Dynamic 5 with 5...

Страница 7: ...Audible Noise 40 dB ANSI Scale A at 3 UNIT DESCRIPTION AT SYCHRONIZED SINEWAVE MODELS 1 Power Switch 2 Alarm Silencer Test momentary rocker switch 3 AC Normal LED Green On when commercial voltage is...

Страница 8: ...15P Plug standard or AWG 12 3 SJT AT2300 with NEMA L5 30P Plug 11 Input Fuse Holder Breaker At650 AT800 and AT2300 units use fuse and fuse holder at input AT1200 and AT1600 units use AC circuit break...

Страница 9: ...r This testing should be repeated 5 to 10 times 3 Verify that UPS and load functions were proper during this testing see items under INSTALLATION AND PRELIMINARY TESTING for UPS function If all functi...

Страница 10: ...y warning IF COMMERCIAL POWER RETURNS BEFORE THE WARNING SIGNAL THERE IS NO NEED TO SHUT DOWN YOUR SYSTEM AT ALL The MINUTEMAN will switch back to normal AC mode operation automatically During normal...

Страница 11: ...ystems also offers its own software package Network Manage which functions with Novell Unix OS 2 LAN Manager LAN Server and MacIntosh Operating Systems Network Manager offers many advantages over exis...

Страница 12: ...mon problems Do not remove the unit cover or attempt to service this unit There are no user serviceable components inside Unauthorized service will void the warranty COMMON UPS PROBLEMS No normal AC m...

Страница 13: ...Other packaging methods can result in damage to the unit Enclose the name and telephone number of the person who can authorize repair charges inside the carton or packing list folder Also include you...

Страница 14: ...INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHER TYPES OR DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OTHER THAN THE LIABILITY STATED ABOVE THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR I...

Отзывы: