Minuteman 957740 Скачать руководство пользователя страница 1

www.minutemanintl.com

1

31218C

Š

36 VOLT AUTOMATIC

BATTERY CHARGER

PART NO. 957740

Specifications

AC Input:

108-128 Volts AC, 15 Amp, 60 Hertz, single-phase

DC Output:

36 Volts DC, 36 Amp

Connections:

6- or 9-ft. AC input cord with NEMA 5-15 grounded plug
8½- or 10-ft. DC output cord with polarized connector

PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

For correct operation of the equipment, it is important to read and be familiar

with this entire manual before installing and operating the charger.

DO NOT DISCARD THIS MANUAL AFTER READING.

LOOK FOR THIS SYMBOL TO POINT OUT SAFETY PRECAUTIONS. IT MEANS:
BECOME ALERT—YOUR SAFETY IS INVOLVED.
  IF YOU DO NOT FOLLOW THESE
SAFETY INSTRUCTIONS, INJURY OR PROPERTY DAMAGE CAN OCCUR.

Features

Patented electronic timer monitors battery state of charge while charging and automatically turns charger off as battery
reaches full charge

Compensates automatically for AC input line voltage variation by high reliability ferroresonant transformer design.  Supply
voltage var 10% from nominal, + 1% maximum battery charger voltage variation, decreasing to + ½% at finish rate
with constant electrolyte temperature.  No taps or rate controls to set.

Automatic decrease of charge rate for superior battery life through good equalization of cells and low water use rate.

Silicon diodes with inherent surge protection operated at a conservation percentage of their rating.

Convection-cooled design for maximum reliability and minimum maintenance.

INTRODUCTION
This automatic battery charger is designed to
recharge deep-cycle, lead-acid batteries.  A
ferroresonant transformer is used to provide a highly
reliable, line compensating unit with a minimum of
moving parts, designed for long, trouble-free service.
A patented electronic timer turns the charger on and
off automatically.  This electronic timer determines
full charge of the batteries by measuring the rate at

which the battery voltage increases during charge.
When the voltage stops rising, the battery is full
charged and the charger turns off.

INITIAL INSTALLATION

The AC line to which the charger is to be connected
must be capable of supply 15 amperes to this
charger.

CAUTION:  USE ONLY ON CIRCUITS

PROVIDED WITH A MAXIMUM OF 20 AMP
(15 

AMP IN CANADA) BRANCH CIRCUIT

PROTECTION IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE ANSI/NFPA 70
AND ALL LOCAL CODES AND ORDINANCES.
IMPROPER CIRCUIT PROTECTION MAY RESULT
IN A FIRE.

Содержание 957740

Страница 1: ...inish rate with constant electrolyte temperature No taps or rate controls to set Automatic decrease of charge rate for superior battery life through good equalization of cells and low water use rate Silicon diodes with inherent surge protection operated at a conservation percentage of their rating Convection cooled design for maximum reliability and minimum maintenance INTRODUCTION This automatic ...

Страница 2: ...CAN RESULT IN A RISK OF ELECTRIC SHOCK The conductor with insulation having an outer surface that is green with or without yellow stripe s is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding connector to a live terminal Refer to a qualified service agent Battery chargers equipped with a grounding plug as ill...

Страница 3: ...te will decrease to 6 to 10 amperes for the last few hours of charge if all battery cells test good During charge the battery voltage increases gradually causing the charge rate to decrease Good battery cells should each rise to approximately 2 5 volts DC causing the charge rate to reduce to less than 10 amps Each cell accepts charge differently normal charging with the ammeter reading in the 6 to...

Страница 4: ... to know how long the batteries have been stored 3 Limit the use of new batteries for the first 20 cycles New batteries and older batteries that have been in storage are not capable of their rated output until they have been discharged and charged a number of times 4 Do not excessively discharge the batteries Excessive discharge can cause polarity reversal of individual cells resulting in complete...

Страница 5: ... the event one or both rectifier diodes fail or a reverse polarity connection is made to the batteries Check the fuse assembly visually for an open or blown fuse link If both half links of the fuse assembly blow as soon as the DC output plug is connected to the battery connector the polarity of the batteries may be reversed If no battery or connector maintenance has been performed prior to the fus...

Страница 6: ... FUSE ASSEMBLY 16823S 1 AMMETER 50 AMP W CORNER MOUNTING STUDS 24840S 1 TIMER KIT 36 VDC 120 VAC 04484S 1 RELAY FOR ELECTRONIC TIMER 23385S 1 RELAY FOR ELECTRONIC TIMER 04484S 1 TIMER KIT RELAY 36 VDC SPSTNO 120 VAC 02028S 1 CORDSET BUSHING 7W 2 FOR 14 3 INPUT CORDSET 02008S 1 CORDSET BUSHING 8P 2 FOR 10 2 OUTPUT CORDSET 02506S 1 AC CORDSET 14 3 72 W 125V 15A PLUG 08329S 1 DC CORDSET 10 2 108 W SB...

Страница 7: ...ctory to the owner will be paid for by the owner All warranty work accomplished at the Minuteman factory will be completed with a reasonable time after receipt of defective items This warranty does not cover any semiconductor parts such as diodes which are vulnerable to electrical overloads beyond the control of Minuteman This warranty does not cover any charger that has been subject to misuse neg...

Отзывы: