Lubrication Equipment
Weekly Checks
!
Check lubrication lines for cracked, crushed, or damaged tubing or fittings. Also, check
condition of hoses or flexible tubing supplying lubricant to upper connections and other
applicable points.
!
Check out lubrication return lines if they restrict the flow of oil. (CAUTION: DO NOT pour
cleaning solution through lube drain lines — this will contaminate press lubrication oil.)
!
Check for oil leakage from oil seals.
!
Remove any accumulation of water from bowl.
!
Check condition of unit.
!
Fill to line on bowl with Minster Lubricant No. 3.
!
If, after a week of press operation, oil level has not lowered, observe drip rate to make
certain oil is being dispensed by the unit.
Monthly Checks
!
Perform lubricator pump unit maintenance as directed in the separate manual cover-
ing type of unit furnished.
!
Check flexible coupling between motor and pump to make certain it is not loose or slip-
ping under load.
!
Hand lubricate screw threads with Lubricant No. 1.
!
Check level of oil in reservoir. Oil should appear near the top of the reservoir with the
lube pump not running. Never fill reservoir while pump is running. Allow sufficient time
for oil in system to drain back after pump is stopped before adding oil. Never permit oil
level to fall below 2.00” from the bottom of the reservoir while press in is operation.
Quarterly Checks
!
Lubricate as necessary. (See instructions in manual.)
!
Install a new 25 micron filter element on the lube unit. Make certain filter is not leaking
oil.
NOTE: Filter must be replaced with new filter of the same type each time the oil in
the reservoir is replaced.
!
Lubricate in accordance with the gearbox manufacturer's recommendations. Do not
over lubricate.
Annual Checks
!
Drain all oil from press reservoir after every 1300 hours of operation.
!
Remove sediment and sludge from reservoir by flushing or, if necessary, clean inside
with lint-free rags.
!
Refill press reservoir to within 1.5” (38 mm) of the top with an approved lubricant meet-
ing the specifications of Minster Lubricant No.1.
!
Install a new 25 micron filter element on the lube unit. Make certain filter is not leaking
oil.
NOTE: Filter must be replaced with new filter of the same type each time the oil in
the reservoir is replaced.
!
Once a year, apply one shot of Minster Lubricant No. 2 through the fitting provided on
the jack gear box.
Lube
Distribution
System
Air Line
Lubricators
Pump Unit
Rotor Seal
Inclining Jack
Oil Reservoir
Lube System
Oil Filter
Feed Drive
Gearbox
(If Furnished)
Oil Reservoir
Lube System
Oil Filter
Inclining Jack
Satisfactory
Unsatisfactory
I - 11
Содержание IOI
Страница 1: ...Manual No 1010C MINSTER 8952 399 15 00 Service Manual OBI OBS SERIES PRESS MODEL...
Страница 2: ...Manual No 1010C MINSTER 8952 399 15 00 Service Manual OBI OBS SERIES PRESS MODEL...
Страница 9: ......
Страница 25: ......
Страница 51: ......
Страница 63: ......
Страница 85: ...I 8 COMMENTS CORRECTIVE STEPS TAKEN Inspected By Press approved for operation Press NOT approved for operation...
Страница 87: ...I 10 COMMENTS CORRECTIVE STEPS TAKEN Inspected By Press approved for operation Press NOT approved for operation...
Страница 89: ...I 12 COMMENTS CORRECTIVE STEPS TAKEN Inspected By Press approved for operation Press NOT approved for operation...
Страница 90: ...ADDITIONAL COMMENTS I 13...