minrray UV570 Скачать руководство пользователя страница 36

FHD PTZ Camera 

 User Manual 

 

30 

 

 
 

 

Содержание UV570

Страница 1: ...HD PTZ Camera User Manual V1 0 Universal Camera...

Страница 2: ...ual is about PTZ camera operation Graphic Symbols Description of graphic symbols used in this manual Symbols Description This symbol indicates that the words are clarification or supplement to this ar...

Страница 3: ...the camera If the camera is very dirty clean it with diluted neutral detergent do not use any type of solvents which may damage the surface Electrical Safety Installation and use of this product must...

Страница 4: ...Manual iii Magnetic Interference Electromagnetic fields at specific frequencies may affect the video image This product is Class A It may cause radio interference in household application Appropriate...

Страница 5: ...oduct Feature 10 2 6 Technical Specification 12 How To Use 16 3 1 Remote Control 16 3 2 IR Remote Control 17 3 2 1 Remote Control Usage 19 3 3 Menu Setting 21 3 3 1 Main Menu 21 3 3 2 English Menu 22...

Страница 6: ...era Control Command 32 5 1 3 Inquiry Command 40 5 2 Pelco D Protocol Command List 44 5 3 Pelco P Protocol Command List 47 Maintenance and Troubleshooting 50 6 1 Camera Maintenance 50 6 2 Unqualified A...

Страница 7: ...485 Interface 2 Base 8 USB3 0 14 LAN Port 3 Receiving Light 9 Audio Input Interface LINE IN 15 Power Input Socket DC12V 4 Infrared Receiver 10 Rotary Dial Switch 16 Power Switch 5 Screw Hole for Tripo...

Страница 8: ...ion Diagram 1 After power on and self check the camera will automatically return to the preset 0 position if it s pre set 2 The default address for the IR remote control is 1 If the menu restored to f...

Страница 9: ...HD PTZ Camera User Manual 3 1 3 Mounting Brackets Ceiling or wall mounting brackets can only be mounted on template and concrete wall For safety reason plasterboard is not recommended 1 3 1 Wall Mount...

Страница 10: ...FHD PTZ Camera User Manual 4 1 3 2 Ceiling Mount...

Страница 11: ...FHD PTZ Camera User Manual 5...

Страница 12: ...Overview 2 1 Dimension Figure1 3 Product Dimension 2 2 Accessory When you unpack your package check that all the supplied accessories are included Table1 1 Supplied Accessory Supplied Power adapter U...

Страница 13: ...ets for wall mounting Brackets for ceiling mount Cascading Cable 2 3 RS 232 1 RS 232 Jack Connection method of camera to PC or Controller Camera WindowsDB 9 1 DTR 1 DCD 2 DSR 2 RXD 3 TXD 3 TXD 4 GND 4...

Страница 14: ...ion 1 DTR Data Terminal Ready 2 DSR Data Set Ready 3 TXD Transmit Data 4 GND Signal Ground 5 RXD Receive Data 6 GND Signal Ground 7 IR OUT IR Commander Signal 8 NC No Connection Table 1 9 RS232 DB9 Po...

Страница 15: ...1 DTR 1 DTR 2 DSR 2 DSR 3 TXD 3 TXD 4 GND 4 GND 5 RXD 5 RXD 6 GND 6 GND 7 IR OUT 7 OPEN 8 NC 8 OPEN Figure1 5 Diagram of Networking Method The product has RS232 input and output interfaces and can be...

Страница 16: ...Product Feature This series camera has perfect functions superior performance and rich video output interfaces Featuring with advanced ISP processing algorithms offering vivid and high resolution vid...

Страница 17: ...ce RS422 is compatible with RS485 RS232 IN RS232 OUT and the RS232 interface supports cascading Multiple Control Protocol Support VISCA PELCO D PELCO P protocols Support automatic identification proto...

Страница 18: ...Output Mainstream YUY2 NV12 1920 1080 1280 720 1024 576 800 600 800 448 640 3 60 640 480 480 270 320 180 30 25 20 15 10 5fps MJPG H264 1920 1080 1600 896 1280 720 1024 576 960 540 800 600 800 448 720...

Страница 19: ...me Tracking Maximum Tracking Range 6 7 meters Support speakers to walk at a speed of 3 4 meters Regional Tracking Maximum Tracking Region 4 Support set the region within horizontal 170 170 and vertica...

Страница 20: ...Communication Protocol VISCA Pelco D Pelco P support baud rate 115200 38400 9600 4800 2400 USB Communication Protocol UVC video communication protocol UAC audio communication protocol Power Interface...

Страница 21: ...Temperature 10 50 Working Humidity 20 80 Dimension 181mm 115mm 149mm Weight 1 15kg Environment Indoor Accessory Standard Accessory Power adapter RS232 control line USB3 0 connection line remote contr...

Страница 22: ...clear the code of this remote control or re pair the code of the new remote control If the code pairing has been unsuccessful the red LED light flashes for 20 seconds and then goes out stop the code p...

Страница 23: ...ss the camera will step into standby mode Long press 3S again the camera will self test again and back to HOME position Note If power on mode is turned on and Preset 0 is set and there is no operation...

Страница 24: ...6 Restore factory defaults 3 9 Flip switch 4 Auto Enter into the aging mode 5 3 Menu set to Chinese 6 4 Menu set to English 7 Manual Restore the default user name password and IP address 8 0 Switch th...

Страница 25: ...nning preset positions via the IR remote controller Key Instruction 1 In this instruction press the key means a click rather than a long press and a special note will be given if a long press for more...

Страница 26: ...tion of focus will keep continue and stops as soon as the key is released 5 BLC Setting BLC ON OFF support 6 Presets Setting Running Clearing 1 Preset setting to set a preset position the users should...

Страница 27: ...esets 7 Camera Remote Controller Address Setting F1 Camera Address No 1 F2 Camera Address No 2 F3 Camera Address No 3 F4 Camera Address No 4 3 3 Menu Setting Note The modification valid only if exit t...

Страница 28: ...FHD PTZ Camera User Manual 22 3 3 2 English Menu...

Страница 29: ...below Firstly open the window of Local Area Connection Properties on computer select the Internet protocol version 4 TCP IPv4 as shown by picture on the left Double click or click the property Interne...

Страница 30: ...twork connection as steps above mentioned after the finish of camera self check If IP is default open DOS command window and input 192 168 5 163 then press Enter key It will show message as below whic...

Страница 31: ...playback and logout No configuration right 2 Browsers that support Web function are Google IE 360 and other popular browsers Language Selection On the right top of the interface display English click...

Страница 32: ...o obtain the RTSP video stream is as below rtsp 192 168 5 163 554 live av0 av0 main stream rtsp 192 168 5 163 554 live av1 av1 sub stream The default IP address of the camera is 192 168 5 163 the way...

Страница 33: ...r default port number Stream name live test live XXX Username and password the username and password set by the server or leave it empty Access url rtmp host domain name host port live xxx Or rtmp hos...

Страница 34: ...version to make sure software upgrade successful Then click restore factory default reboot and restore parameters to factory default default IP 192 168 5 163 user name admin password admin 4 5 Webpage...

Страница 35: ...on 2 After finishing region1 setting click Set to complete the Region1 Tracking Other region settings are same as region1 setting steps You can set 4 different regions and minimum 2 regions And the Re...

Страница 36: ...FHD PTZ Camera User Manual 30...

Страница 37: ...led to the farthest position and then pulled back after that self test is completed 5 1 VISCA Protocol List 5 1 1 VISCA Protocol List Ack Completion Message Command packet Remark ACK z0 41 FF Returned...

Страница 38: ...o Inquiry command 0 Returned when a command canot be executed due to current conditions For example when commands controlling the focus manually are received during auto focus 5 1 2 Camera Control Com...

Страница 39: ...18 01 FF One Push Triger CAM _Zoom Focus Direct 8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 0w FF pqrs Zoom Position tuvw Focus Position CAM_AF Sensitivity High 8x 01 04 58 01 FF Focus sensitivity Setting Normal...

Страница 40: ...Setting Normal 8x 01 04 A9 01 FF High 8x 01 04 A9 02 FF CAM _RGain Reset 8x 01 04 03 00 FF Manual Control of R Gain Up 8x 01 04 03 02 FF Down 8x 01 04 03 03 FF Direct 8x 01 04 43 00 00 0p 0q FF pq R...

Страница 41: ...8x 01 04 0B 02 FF Down 8x 01 04 0B 03 FF Direct 8x 01 04 4B 00 00 0p 0q FF pq Iris Position CAM_Gain Limit Reset 8x 01 04 0C 00 FF Gain Limit Setting Up 8x 01 04 0C 02 FF Down 8x 01 04 0C 03 FF Gain...

Страница 42: ...0 0p FF p WDR Level Positon CAM_NR 2D 8x 01 04 53 0p FF P 0 7 0 OFF 3D 8x 01 04 54 0p FF P 0 8 0 OFF CAM_Gamm a 8x 01 04 5B 0p FF p 0 4 0 Default 1 0 45 2 0 50 3 0 55 4 0 63 CAM_Low Light Mode ON 8x 0...

Страница 43: ...e verse On 8x 01 04 61 02 FF Image Flip Horizontal ON OFF Off 8x 01 04 61 03 FF CAM_Picture Flip On 8x 01 04 66 02 FF Image Flip Vertical ON OFF Off 8x 01 04 66 03 FF CAM_ColorS aturation Direct 8x 01...

Страница 44: ...Flip H 8x 01 04 A4 01 FF Flip V 8x 01 04 A4 02 FF Flip HV 8x 01 04 A4 03 FF CAM_VideoS ystem Set Camera video system 8x 01 06 35 00 0p FF P 0 E Video format Pan_tiltDrive Up 8x 01 06 01 VV WW 03 01 F...

Страница 45: ...0Z 0Z 0Z FF Home 8x 01 06 04 FF Reset 8x 01 06 05 FF Pan tiltLimitSet Set 8x 01 06 07 00 0W 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF W 1 UpRight 0 DownLeft YYYY Pan Limit Position TBD ZZZZ Tilt Limit Position TBD C...

Страница 46: ...03 FF Manual Focus y0 50 04 FF One Push mode CAM_FocusP osInq 8x 09 04 48 FF y0 50 0p 0q 0r 0s FF pqrs Focus Position CAM_AFSensi tivityInq 8x 09 04 58 FF y0 50 01 FF High y0 50 02 FF Normal y0 50 03...

Страница 47: ...FF y0 50 00 00 0p 0q FF pq R Gain CAM_BGainIn q 8x 09 04 44 FF y0 50 00 00 0p 0q FF pq B Gain CAM_AEMod eInq 8x 09 04 39 FF y0 50 00 FF Full Auto y0 50 03 FF Manual y0 50 0A FF Shutter priority y0 50...

Страница 48: ...RLeve l 3D Inq 8x 09 04 54 FF y0 50 0p FF P 3D NRLevel CAM_FlickerM odeInq 8x 09 04 55 FF y0 50 0p FF p Flicker Settings 0 OFF 1 50Hz 2 60Hz CAM_Apertur eInq 8x 09 04 42 FF y0 50 00 00 0p 0q FF pq Ape...

Страница 49: ...tness Position CAM_Contrast Inq 8x 09 04 A2 FF y0 50 00 00 0p 0q FF pq Contrast Position CAM_FlipInq 8x 09 04 A4 FF y0 50 00 FF Off y0 50 01 FF Flip H y0 50 02 FF Flip V y0 50 03 FF Flip HV CAM_Gamma...

Страница 50: ...iltPosInq 8x 09 06 12 FF y0 50 0w 0w 0w 0w 0z 0z 0z 0z FF wwww Pan Position zzzz Tilt Position x y x 8 5 2 Pelco D Protocol Command List Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Up 0xFF Addr...

Страница 51: ...cus Near 0xFF Address 0x01 0x00 0x00 0x00 SUM Stop 0xFF Address 0x00 0x00 0x00 0x00 SUM Set Preset 0xFF Address 0x00 0x03 0x00 Preset ID SUM Clear Preset 0xFF Address 0x00 0x05 0x00 Preset ID SUM Call...

Страница 52: ...FHD PTZ Camera User Manual 46 Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Query Zoom Position Response 0xFF Address 0x00 0x5D Value High Byte Value Low Byte SUM...

Страница 53: ...FHD PTZ Camera User Manual 47 5 3 Pelco P Protocol Command List...

Страница 54: ...peed 0xAF XOR DownLeft 0xA0 Address 0x00 0x14 Pan Speed Tilt Speed 0xAF XOR DownRight 0xA0 Address 0x00 0x12 Pan Speed Tilt Speed 0xAF XOR Zoom In 0xA0 Address 0x00 0x20 0x00 0x00 0xAF XOR Zoom Out 0x...

Страница 55: ...AF XOR Query Tilt Position 0xA0 Address 0x00 0x53 0x00 0x00 0xAF XOR Query Tilt Position Response 0xA0 Address 0x00 0x5B Value High Byte Value Low Byte 0xAF XOR Query Zoom Position 0xA0 Address 0x00 0...

Страница 56: ...mage may flicker Do not operate close to powerful electromagnetic radiation such as TV or radio transmitters etc 6 3 Troubleshooting No image 1 Check whether the power cord is connected voltage is OK...

Страница 57: ...the building and any supporting furniture for vibration Ceiling mounts are often affected by building vibration more than wall mounts 3 Any external vibration that is affecting the camera will be more...

Страница 58: ...inrray Industry Co Ltd may not be cloned copied or translated in any way without the explicit permission of the company Product specifications and information referred to in this document are for refe...

Отзывы: