2.2 Mode:
o
HEATING
. The device will only function in heating mode.
o
COOLING
. The device will only function in cooling mode.
o
AUTOMATIC
. The device will function in either heating or cooling mode,
depending on the season. It switches between modes based on a
sophisticated algorithm that protects against false changes of season.
2.3 Units:
o
°C
. Temperature will display in Celsius units
o
°F
. Temperature will display in Fahrenheit units.
“T
EMPERATURE
”
SETTINGS SCREEN
(
CONT
’
D
)
Figure 44
–
Examples of options to adjust auxiliary (central) heating units.
The MINOTAIR can control auxiliary heating units such as electric and gas furnaces and
heat pumps as long as they can be controlled through a 24 VAC signal.
NOTE
. Forced air units must be connected to the
“G” terminal to synchronize
ventilation with that of the MINOTAIR.
2.4 Auxiliary Heating?
o
NO
. The MINOTAIR does not control any auxiliary heating unit.
o
YES
. The MINOTAIR controls an auxiliary heating unit. The control signal
follows a call for heat for which the MINOTAIR was unable to reach the
requested temperature setpoint within 5 to 25 minutes depending on outside
air temperature, or if indoor temperature is 1°C (1.8°F) under the temperature
setpoint.
2.4.1 Fan Source:
o
MINOTAIR
. The MINOTAIR controls a 5 kW electric coil (not supplied) in line
with its distribution conduit. The control signal is a 24 VAC voltage to the "W"
terminal.
See “
Connecting to a 5 kW Electric Coil (Installation Option)
for
further details.
o
AUXILIARY
. The MINOTAIR sends a heating signal to the heating terminal "W"
located on the connection terminal block and will let the auxiliary unit manage
the transition from one stage to another if appropriate. In the case of a heat
pump, the signal will rather come from the "Y" terminal.
See “
an Auxiliary Heat Pump (Installation Option)
for further details.
2.4
_
2.4.1
2.4.2