4.
I
NTERMITTENT
M
ODE
•
This is a mixed mode that alternates between Air Exchanger and Recirculation
modes. Four settings are possible:
•
Intermittent-10
. Activates Air Exchanger Mode for 10 minutes before
switching to Heat Pump Mode for 50 minutes, and so on.
•
Intermittent-20
. Activates Air Exchanger Mode for 20 minutes before
switching to Heat Pump Mode for 40 minutes, and so on.
•
Intermittent-30
. Activates Air Exchanger Mode for 30 minutes before
switching to Heat Pump Mode for 30 minutes, and so on.
•
Intermittent-40
. Activates Air Exchanger Mode for 40 minutes before
switching to Heat Pump Mode for 20 minutes, and so on.
•
Intermittent Mode features include:
o
Lower energy consumption.
o
All the benefits of Air Exchanger and Heat Pump Modes, depending on the
type of intermittency selected.
•
When to use:
o
When it is necessary to have a guaranteed time-based supply of fresh air.
o
Ideal during prolonged absences to ensure a minimum supply of fresh air.
o
If air becomes too dry in winter, lower the intermittency as needed.
o
Could tend to over-ventilate if intermittency is set too high.
and
or
Figure 7
–
Intermittent Mode 10, 20, 30 or 40
–
with heat pump recirculation.