FrameMaker Ver.5.5E(PC) EP3000/EP3010 TROUBLESHOOTING
98.08.06
T-2
To allow the Tech. Rep. to easily and safely determine whether a particular controlled part
is fully operational, this copier provides the following provision: checking the data of the I/O
port of the board IC with the copier in the standby state (including a misfeed, malfunction,
and closure failure condition) allows the Tech. Rep. to determine whether a signal is prop-
erly input to, and output from, a controlled part.
<Procedure>
1. On the circuit diagram accompanying the text, locate the I/O port of the controlled part
which is probably defective when a misfeed or malfunction occurs.
2. Select the “IC Port Data Check” function of “I/O Check” in the Tech. Rep. mode and
access the screen which contains the port identified in step 1 above. (See SWITCHES
ON PWBs/TECH. REP. MODE.)
3. Change or check the input or output port data to determine whether the controlled part
is operational and signals are properly input and output.
4. If the controlled part does not operate properly after changing the output port data,
select “Controller Board Check” of “I/O Check” in the Tech. Rep. mode and determine
whether the board is responsible for that malfunction or not.
Note
Only the output ports given on pages T-37 and 38 may be checked by “Controller Board
Check” of “I/O Check” in the Tech. Rep. mode.
43
I/O PORT CHECK
43-1. Controlled Parts Check Procedure
Содержание EP3000
Страница 1: ...FrameMaker Ver 5 5E PC EP3000 EP3010 GENERAL MECHANICAL ELECTRICAL 98 06 10 EP3010 GENERAL ...
Страница 16: ...FrameMaker Ver 5 5E PC EP3000 EP3010 GENERAL MECHANICAL ELECTRICAL 98 06 10 EP3010 MECHANICAL ELECTRICAL ...
Страница 154: ...FrameMaker Ver 5 5E PC EP3000 EP3010 DIS REASSEMBLY ADJUSTMENT 98 05 29 EP3010 DIS REASSEMBLY ADJUSTMENT 18605 ...
Страница 235: ...FrameMaker Ver 5 5E PC EP3000 EP3010 TROUBLESHOOTING 98 08 06 EP3010 TROUBLESHOOTING 10794 ...