FrameMaker Ver5.5E(PC) CF3102/CF2002 DIS/REASSEMBLY, ADJUSTMENT
02.06.010
D-67
(22) CD-Mag.
Requirement
This adjustment must be made in any of the following cases:
• The CCD Unit has been replaced.
• The lens has been replaced.
Adjustment Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch these keys in this order: “Machine Adjust”
→
“IR Area.”
3. Touch “CD-Mag.”
4. Place a scale on the Original Glass so that it runs parallel with the Original Width Scale
and its leading edge is aligned with the Original Length Scale.
5. Press the Start key to make a copy.
6. Check the image on the copy produced.
7. If the image does not meet the specifications, change the setting using the Up/Down
key.
• If the specified width on the copy is less than 199 mm, increase the setting.
• If the specified width on the copy exceeds 201 mm, decrease the setting.
8. Press the Start key to make a copy.
9. Check the image on the copy to see if the specifications are met.
10. If it fails to meet the specifications, change the setting and make a check again.
11. If it meets the specifications, touch “END.”
Specifications
Adjustment Mode
Setting Range
200
±
1.0 mm
CD-Mag.
0.990 to 1.010
• The 200-mm width of the scale on the sample copy
produced should fall within the following range.
• The adjustment of Zoom for FD on the printer side
must have been made to meet the specifications.
D-50
4004D516AB
200 mm
Содержание CF2002
Страница 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Страница 2: ......
Страница 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Страница 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Страница 58: ...FrameMaker Ver 5 5E PC CF2002 CF3102 DIS REASSEMBLY ADJUSTMENT 02 06 26 DIS REASSEMBLY ADJUSTMENT 14413 ...
Страница 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...