background image

POLYTOR POWER PACK

P30

OPERATION MANUAL

Products are subject to change without notice.

Содержание ONE Series

Страница 1: ...POLYTOR POWER PACK P30 OPERATION MANUAL Products are subject to change without notice ...

Страница 2: ...ck Failure to do so could result in fire and or electric shock Do not close the air holes on the top of the power pack Failure to do so could result in increasing temperature inside of the power pack resulting in fire and or failure Always wear safety glasses and a mask for dust Chips and or dust left after grinding polishing process could result in unexpected injury Always ask us for repair Failu...

Страница 3: ...h fixed amplitude amount POWER MODE The power may be enhanced by increasing of maximum drive voltage on STROKE CONTROL mode only Digital Display of Frequency Indicating vibration frequency of handpiece Error Code Display Function To warn abnormality of the powerpack and handpieces by displaying error codes LED Level Meter Indicating amplitude amount of handpiece by 8 LED lights Resume Function Pre...

Страница 4: ... while POWER MODE is activated If POWER MODE was activated maximum drive voltage is increased and power to sustain amplitude amount becomes stronger POWER MODE switch does not work on VOLTAGE CONTROL mode POWER MODE switch is always off when turning on the main power supply switch ULTRA SONIC ON OFF Switch ULTRA SONIC Output Light To use and control On Off of a handpiece Pressing the ULTRA SONIC O...

Страница 5: ...rn the main switch off to cancel STROKE CONTROL Voltage is increased decreased for stable amplitude amount of handpiece STROKE CONTROL mode is suitable for heavy load works such as deburring and rough finishing because it tries to keep constant amplitude amount POWER MODE is effective for heavy load works because it tries to keep constant amplitude amount Use VOLTAGE CONTROL mode or decrease ampli...

Страница 6: ...witch off to cancel 8 Trouble Shooting 9 10 POWER PACK Malfunction on behavior of Power Pack was detected restarted forcibly Press ULTRASONIC ON OFF switch or hand switch POWER PACK are detected Malfunction on panel substrate was detected POWER PACK Press ULTRASONIC ON OFF switch or hand switch Press ULTRASONIC ON OFF switch or hand switch turn the foot switch off mount SENTANTOOL certainly or ins...

Страница 7: ...g or use VOLTAGE CONTROL mode Is there any slackness of installation on tool or holder Make sure that tool and holder are installed certainly Decrease value indicated by power control knob if tool and holder loosened frequently Vibration becomes weak while working Is there any damage such as burn and crack on tool Form tool or change to new tool Decrease value indicated by power control knob if to...