background image

SMART IP ACCESS

 

1. Welcome 

Thank you for buying the Smart IP Access system. This system is produced by 
Minicom Advanced Systems Limited. 

This document provides installation and operation instructions for Minicom’s 
Smart IP Access. It is intended for system administrators and network managers, 
and assumes that readers have a general understanding of networks, hardware and 
software. 

Technical precautions  

This equipment generates radio frequency energy and if not installed in accordance 
with the manufacturer’s instructions, may cause radio frequency interference.  
This equipment complies with Part 15, Subpart J of the FCC rules for a Class A 
computing device. This equipment also complies with the Class A limits for radio 
noise emission from digital apparatus set out in the Radio Interference Regulation 
of the Canadian Department of Communications. These above rules are designed to 
provide reasonable protection against such interference when operating the 
equipment in a commercial environment. If operation of this equipment in a 
residential area causes radio frequency interference, the user, and not Minicom 
Advanced Systems Limited, will be responsible. 
Changes or modifications made to this equipment not expressly approved by 
Minicom Advanced Systems Limited could void the user’s authority to operate the 
equipment.  
Minicom Advanced Systems Limited assumes no responsibility for any errors that 
appear in this document. Information in this document is subject to change without 
notice. 
No part of this document may be reproduced or transmitted in any form or by any 
means, electronic or mechanical, for any purpose, without the express written 
permission of Minicom Advanced Systems Limited. 

Trademarks 

All trademarks and registered trademarks are the property of their respective 
owners. 

2. Introduction 

The Smart IP Access extends your KVM (keyboard, video, mouse) from any 
computer or server over TCP/IP via LAN, or WAN. Now you can control, monitor 
and manage your servers from wherever you are, inside or outside the organization. 
The Smart IP Access is a cost-effective hardware solution, for secure remote KVM 
access & control of a computer/server from the BIOS level - independent of the 
OS. It is designed to connect to a single computer or to a KVM switch to access 

Содержание Smart IP Access

Страница 1: ...2 2 535 9666 minicom minicom com North American HQ Linden NJ USA Tel 1 908 486 2100 info usa minicom com European HQ D bendorf Switzerland Tel 41 44 823 8000 info europe minicom com Technical support...

Страница 2: ...ate notes 11 12 Network Configuration 11 12 1 LAN 1 12 12 2 KVM net 12 13 Network SNMP settings 13 14 Administration User Settings 13 14 1 Administrator 14 14 2 User 14 14 3 View only 14 14 4 Adding a...

Страница 3: ...Video Adjust 26 24 7 Power cycle 26 24 8 Keyboard key sequences 26 24 9 Synchronizing mouse pointers 28 24 9 1 Aligning the mice pointers 28 24 9 2 Calibrating mice pointers 28 24 9 3 Manual mice sync...

Страница 4: ...a residential area causes radio frequency interference the user and not Minicom Advanced Systems Limited will be responsible Changes or modifications made to this equipment not expressly approved by...

Страница 5: ...use Web based Access Browser access to a target server from any location via secured standard IP connection SNMP SNMP traps for monitoring Smart IP Access events and operation Multi user view mode Al...

Страница 6: ...ss disconnects the Client computer s link to the Target Server and the Local Mouse and Keyboard become operational Reset Restarts the Smart IP Access unit The figure below illustrates the rear panel o...

Страница 7: ...be greater than the room ambient when installing into a closed or multi unit rack assembly So install the equipment in an environment compatible with the maximum rated ambient temperature Reduced airf...

Страница 8: ...that are accessed remotely via the Smart IP Access Client computer The PC running a remote Smart IP Access session Remote Session The process of accessing and controlling Target Servers connected to S...

Страница 9: ...ect to the power supply using the power cord provided Figure 4 and Figure 5 illustrate the connections to a computer and KVM switch respectively with the optional KVM console 3 in 1 CPU cable Target P...

Страница 10: ...0 VAC 50 60 Hz www minicom com CONSOLE COMPU TER 2 2 1 1 L A N S E R I A L User over IP hp 192 5 A u t o 1 2 LAN WAN Figure 5 Smart IP Access connections to a KVM switch 10 Default IP address Smart IP...

Страница 11: ...browser Internet Explorer version 6 0 or higher 2 Type the IP address of the Smart IP Access system https IP address config and press Enter The login page appears see Figure 6 Figure 6 Login page 3 T...

Страница 12: ...cess Default device name consists of the letter D followed by the 6 digit device number D N found on the silver label on the underside of the IP Access box First TCP Port Choose 3 consecutive ports an...

Страница 13: ...the Web configuration menu can only be accessed from LAN 2 This may be useful when dedicating LAN 2 to LAN access only to enhance security When DHCP is disabled enter an IP Address Subnet Mask and De...

Страница 14: ...eck to enable SNMP traps of Smart IP Access events and operation Community type the SNMP community SNMP Manager IP Enter the SNMP Server IP address To save changes click 14 Administration User Setting...

Страница 15: ...ly limited options appear such as switching Servers and Disconnect Explained on pages23 and 31 A view only indicator appears on the viewer s local mouse pointer 14 4 Adding a user To add a user 1 Clic...

Страница 16: ...ges are saved 14 7 Blocking a user An alternative to deleting a user is blocking a user This means that the user s name and password is stored but the user is unable to access the system Check Block t...

Страница 17: ...stall switch definition file Where the KVM switch type is not listed in the manufacturer model drop down lists contact Minicom to request an updated Switch Definition file with the desired KVM switch...

Страница 18: ...ce appear in the list of servers devices that can be accessed Where there is no device connected to the particular Serial port uncheck Show 17 Security Settings Configure the security features such as...

Страница 19: ...l character as follows _ Must not include the user name Must not include the user name Check the box to enable the high security password policy Unchecked the standard security policy applies Idle Tim...

Страница 20: ...ding various events security alerts system alerts configuration changes and user activity Figure 14 Event log 20 Maintenance Set System Time From the menu select Set System Time The Time Settings page...

Страница 21: ...page see page 12 all firmware upgrades are done via KVM net b Depending on the type of firmware upgrade the following settings may be erased User settings KVM switch settings mouse and video adjustmen...

Страница 22: ...on 24 Starting a remote session At a Client computer open Internet Explorer 6 0 and above and type the Smart IP Access s IP address https IP address The Login box appears Type your username and passwo...

Страница 23: ...ut not by an Administrator The following message appears Figure 19 Busy remote session options Choose to take over or view only or cancel 24 2 Full screen mode Work on the Target Server as if you are...

Страница 24: ...oolbar The Toolbar can be dragged and dropped to anywhere on the screen by clicking and dragging the logo To hide the Toolbar either Double click the Smart IP Access System tray Icon Or Press F9 To di...

Страница 25: ...automatically adapts to the best compression and colors Low Select Low for high compression and 16 colors Medium Select medium for medium compression and 256 colors Medium is recommended when using a...

Страница 26: ...t Server 24 6 2 Manual Video Adjust Use the manual video adjustment for fine tuning the Target Server video settings after auto adjustment or for adapting to a noisy environment or a non standard VGA...

Страница 27: ...ally We recommend opening Windows Explorer or similar in the background Click Auto Video Adjust The process takes a few seconds If the process runs for more than 3 times there is an abnormal noise lev...

Страница 28: ...cial Key Manager box 3 Click OK The sequence appears in the Keyboard Key sequence list To record a key sequence 1 From the Special Key Manager box press Record New The Add Special Key box appears see...

Страница 29: ...ointers When accessing the Target Server the mice may appear at a distance to each other To align the mouse pointers From the Toolbar click Align or press Ctrl M simultaneously The mice align 24 9 2 C...

Страница 30: ...ters 1 From the Toolbar click Manual Settings The Mouse Settings box appears see Figure 24 Figure 24 Mouse Settings box 2 Select the Target Server s Operating System and click OK Instructions and slid...

Страница 31: ...gure 25 Mouse Emulation box Select the mouse connected to the Local Console port on the Smart IP Access e g if the local mouse is a non Microsoft 2 button mouse select Standard Mouse and uncheck Micro...

Страница 32: ...een mode from the next reconnection onwards To toggle the full screen mode on and off press F11 24 11 Disconnecting the remote session To disconnect the session on the Toolbar click The Login box appe...

Страница 33: ...username and password works only after the reset procedure described above A menu appears see Figure 28 Figure 28 Menu 8 From the menu choose Restore Factory Settings A warning appears see Figure 29 F...

Страница 34: ...nto your web browser The Login page appears as in Figure 6 on page 10 12 Type the default Administrator user name and password Username admin password access Case sensitive 13 Configure the unit accor...

Страница 35: ...Server Video and mouse synchronization Both auto and manual modes Connections Ethernet 2 X RJ45 10 100 Mbit sec autosensing Serial 2 X RJ45 Local KVM connection Screen HDD15 Keyboard Mouse MiniDIN6 Co...

Страница 36: ...t only be opened by an authorized Minicom technician Disconnect device from AC mains before service operation Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used batt...

Страница 37: ...electrical and electronic equipment from Minicom they are entitled to Send old equipment for recycling on a one for one like for like basis this varies depending on the country Send the new equipment...

Страница 38: ...y Kiel Tel 49 431 668 7933 info germany minicom com France Vincennes Tel 33 1 49 57 00 00 info france minicom com Italy Rome Tel 39 06 8209 7902 info italy minicom com England Camberley Tel 44 0 1276...