INSTALLATION GUIDE – WALL-MOUNTED CONVECTORS

1. UNIT DESCRIPTION

A wall-mounted heating unit. Models NUF1, NUF2, NMF1, 
NWF1, NWF2, NPF1, and NPF2 use the natural convection 
heating principle, models NKF1 and NKF2 are equipped 
with a fan for forced convection. Since the heater uses 
physical laws of thermodynamics it represents one of the 
most effi cient methods of interior heating.

Benefi ts of heating convectors:

  High output
  Silent operation or low noise for units with fan 
  Lightweight compared to heating units with similar 

output which use radiation principle

  Low hot water consumption
  Short response time
  Design
  Minimum requirements for operation and mainte-

nance

  A great advantage of these convectors is the small 

required  installation  space.  This  is  benefi cial  par-
ticularly in a situation where the heating units are 
used in interior renovation and replacement of old 
heaters with new ones and in situations where suf-
fi cient heating output is required.

3. TECHNICAL PARAMETERS

  Use: Convectors without fan are designed for dry 

and wet environment, and convectors with a fan 
are designed for dry environment only.

  Maximum operating pressure: 1 MPa. 
  Maximum operating temperature: 110 °C. 
  Operating medium: Water. It is not allowed to use a 

medium other than water. Water may not be mixed 
with other substances, such as antifreeze fl uids!

  Environment:  interiors  with  temperatures  ranging 

b5 °C and +40 °C.

1.   CONVECTOR  BODY  –  Aluminum  convector  frame 

painted with color shade according to the catalog.

2.   HEAT  EXCHANGER  –  Copper  pipes  with  pressed-

-on aluminum fi ns through which the heating water 
fl ows. The heat exchanger design differs according 
to the convector model.

3.   COVERING GRILLE – Grille used to cover the convec-

tor outlet; with color shade according to the catalog.

4.   AXIAL FAN (models with a fan) – Set of fan modules 

for forced convection of the heated air. The number 
differs according to the length of the convector.

5.   EB CONTROL UNIT (models with a fan) – Fan motor 

control unit.

6.   EB  CONTROL  UNIT  BRACKET  (models  with  a  fan) 

– Used for fi tting the control unit on the convector 
casing.

7.  TEMPERATURE SENSOR (models with a fan) – Used 

for sensing temperature for the EB control unit.

8.  THERMOSTATIC HEAD – Used for temperature con-

trol and operation of the axial valve.

9.  AXIAL  THERMOSTATIC  VALVE  –  A  valve  used  for 

incoming heating water fl ow control.

10. CONTROL  SCREW  FITTING  –  A  valve  which  cont-

rols/adjusts the heating water fl ow.

11. GASKET  RING  –  A  gasket  in  the  connection  be-

tween the valve and the heat exchanger.

12. WALL SCREW – A screw used to attach the convec-

tor to the wall.

13. SCREW ANCHOR – For attaching the convector to 

the wall.

Each position in the table corresponds to Figure No. 1.

FIG. 1: 

COMPONENTS AND DESCRIPTION OF THE CONVECTOR PARTS

Contents of the box

NKF1

NKF2  NUF1

NUF2 NMF1 NWF1 NWF2 NPF1

NPF2

Convector

Grille

1

1

1

1

1

1

1

1

1

Convector body

1

1

1

1

1

1

1

1

1

Heat exchanger

1

1

1

1

1

1

1

1

1

Grille reinforcement

1

1

1

1

1

1

1

1

1

Cable grommet

1

1

-

-

-

-

-

-

-

Fan – assembly of modules

2-4

2-4

-

-

-

-

-

-

-

EB control unit

1

1

-

-

-

-

-

-

-

Accessories

Axial radiator valve

1

1

1

1

1

1

1

1

1

Thermostatic head

1

1

1

1

1

1

1

1

1

Control Screw fitting  

1

1

1

1

1

1

1

1

1

2. CONTENTS OF THE BOX

4. DESIGN DETAILS, CONNECTION DIMENSIONS, PLACEMENT

FIG. 2: 

Rear view

L = Standard CONVECTOR LENGTH: 900, 1000, 1250, 1500, 1750, 2000 mm