INSTALLATION GUIDE – WALL-MOUNTED CONVECTOR NK2 

1. UNIT DESCRIPTION

A wall-mounted NK2 heating unit equipped with fans. 
Since the heater fully uses physical laws of thermody-
namics it represents one of the most effi cient methods 
of interior heating.  

Benefi ts of heating convectors:

  High output
  Silent operation or low noise for units with fan 
  Lightweight compared to heating units with similar 

output which use radiation principle

  Low hot water consumption
  Short response time
  Design
  Minimum requirements for operation and mainte-

nance

  A great advantage of these convectors is the small 

required installation space. This is benefi cial par-
ticularly in a situation where the heating units are 
used in interior renovation and replacement of old 
heaters  with  new  ones  and  in  situations  where 
suffi cient heating output is required.

Contents of the box

Position

NK2

Convector

Plastic cover

7

2

Grille

6

1

Convector body

5

1

Support member

13

1

Heat exchanger

3

1

Grille reinforcement

8

1

Cable grommet

2

1

Fan

15

1-2

EB control unit

1

1

Accessories

Axial radiator valve

11

1

Thermostatic head

12

1

Control Screw fi tting  

10

1

3. TECHNICAL PARAMETERS

  Use: dry environment, according to the specifi cation.
  Maximum operating pressure: 1 MPa. 
  Maximum operating temperature: 110 °C. 
  Operating medium: water. Water may not be mixed 

with other substances, such as antifreeze fl uids!

  Environment:  interiors  with  temperatures  ranging 

b5 °C and +40 °C. 

1.  EB CONTROL UNIT – fan motor control unit.
2.  CABLE GROMMET – intended for cable installation 

to the control unit.

3.  HEAT  EXCHANGER  –  copper  pipes  with  pressed-

on  aluminum  fi ns  through  which  the  heating  water 
fl ows.

Each position in the table corresponds to Figure No. 1.

  Select the correct convector type from the cata-

logue – see paragraph 4.1.

  Select the correct convector position and location 

– see paragraph 4.2.

4.1  Suitable Convector Type 

Decide  whether  the  convector  will  act  as  the  main 
source of heat, or an additional heating element or, as 
the case may be, as a heat barrier.
As  the  main  source  of  heat  in  your  apartment  / 
room,  the  convector  should  suffi ciently  cover  the 
entire thermal loss of the room. Therefore, always 
choose a heating unit with a capacity that is higher 
than the thermal loss of your apartment, room, or 
other areas.
All  wall-mounted  convectors  are  designed  for  dry 
environment.  A  dry  environment  is  an  environment 
where  the  average  annual  relative  humidity  does 
not  exceed  75%.  A  wet  environment  is  an  environ-
ment where such average annual value is equal to or 
greater than 75% or where the convector is exposed 
to  direct  contact  with  water.  In  terms  of  convector 
selection,  a  dry  environment  is  in  general  any  envi-
ronment where no precipitation of vapor occurs in the 
convector unit.

FIG. 1: 

COMPONENTS AND DESCRIPTION 

OF THE PARTS OF THE CONVECTOR

 

Design  of  the  heat  exchanger 
differs  depending  on  the  con-
vector model.

4.  AIR  VENT  VALVE  –  used  for 

venting (bleeding) the convec-
tor.

5.  CONVECTOR BODY – aluminum 

convector body.

6.  CONVECTOR GRILLE – a design 

piece  within  the  convector.  It 
must not be covered!!!

7.  PLASTIC  COVER  –  used  for 

attaching the grille to the con-
vector body.

8.  GRILLE  SUPPORTING  MEM-

BER  –  for  supporting  the  con-
vector grille.

9.  ADJUSTING SCREW – used for 

vertical  positioning  of  convec-
tor on the wall.

10. CONTROL  SCREW  FITTING  – 

a  valve  that  controls  /  adjusts 
the heating water fl ow.

11. AXIAL  RADIATOR  VALVE  – 

a valve used for fl ow regulation.

12. THERMOSTATIC  HEAD  –  used 

for manual regulation.

14. RUBBER  ANTI-VIBRATION  PAD  –  for  fl exible 

mounting of the fan module.

15. FAN – used for forced convection.

13. CONVECTOR SUPPORT MEMBER – a fi xing part of 

the  wall-mounted  convector,  supporting  part  for 
the convector body and heat exchanger.

4.2  Convector Position 

Wall-mounted convectors MINIB are intended for in-
stallation  on  the  wall  below  window  frames  or  sills. 
Make  sure  to  follow  the  principle  that  the  distance 
from the fl oor should never be less than 110 mm (Fig-
ure 2). Never cover the upper grille of the convector - 
this would result in fl ow reduction and a considerable 
decrease in the convector output. 

2. CONTENTS OF THE BOX 

4. BEFORE INSTALLATION

FIG. 2: 

For all models – convector position.

Dimensions for marking of mounting holes

Convector length

900

1 000

1 250

1 500

1 750

2 000

NK2

A

760

860

1 110

1 360

1 620

1 860

B

706

804

1 054

1 304

1 564

1 804